LAPP 79104800 Hood Connector Side Entry M40 HB16 - Equivalent & Substitute Parts

Part Overview

The LAPP 79104800 is an EPIC® HB series heavy duty connector hood designed for side entry applications with M40 thread size. This accessory component provides IP65 ingress protection (dust tight, water resistant) and operates across an extended temperature range of -40°C to 100°C. The connector features a locking clip mechanism on the base bottom and is constructed from powder-coated aluminum alloy housing in gray finish.

This part is currently active in production with 764 units in stock. Equivalent substitute parts may be required due to supply chain considerations, regional availability, or system standardization across different connector series while maintaining identical functional and mechanical specifications.

Substiute Parts

79104800
LAPPIn Stock: 85779104800 Datasheet
79104800
Current Part
19300160548
HARTINGIn Stock: 101219300160548 Datasheet
19300160548
Similar

Key Parameters

Parameter Specification
Connector Type Hood
Style Side Entry
Thread Size M40
Size Designation HB16
Ingress Protection Rating IP65 - Dust Tight, Water Resistant
Lock Location Locking Clip (1) on Base Bottom
Housing Material Aluminum Alloy
Housing Finish Powder Coated
Operating Temperature Range -40°C to 100°C
Ingress Protection IP65
Housing Color Gray

Substitute Part Grouping Explanation

Substitution of the LAPP 79104800 with equivalent parts is determined by strict alignment of the following critical parameters:

Mandatory Matching Parameters:

  • Connector Type: Hood
  • Style: Side Entry
  • Thread Size: M40
  • Ingress Protection Rating: IP65 (Dust Tight, Water Resistant)
  • Lock Location: Locking Clip (1) on Base Bottom
  • Housing Material: Aluminum (Alloy or Die Cast)
  • Housing Finish: Powder Coated
  • Housing Color: Gray
  • Physical Dimensions: Within tolerance of 93.30mm L × 43.00mm W × 76.00mm H

The HARTING 19300160548 (Han® B series, size 16B) meets all mandatory substitution criteria. While manufactured by a different supplier and belonging to a different connector series, this part maintains functional and mechanical equivalence for side entry M40 hood connector applications requiring IP65 protection.

Parameter Comparison

Parameter LAPP 79104800 (HB16) HARTING 19300160548 (16B) Match Status
Manufacturer LAPP HARTING Different Manufacturer
Connector Type Hood Hood Equivalent
Style Side Entry Side Entry Equivalent
Thread Size M40 M40 Equivalent
Size Designation HB16 16B Functionally Equivalent
Ingress Protection IP65 IP65 Equivalent
Lock Location Locking Clip (1) on Base Bottom Locking Clip (1) on Base Bottom Equivalent
Housing Material Aluminum Alloy Aluminum, Die Cast Equivalent
Housing Finish Powder Coated Powder Coated Equivalent
Housing Color Gray Gray Equivalent
Length 93.30mm 93.50mm Within Tolerance
Width 43.00mm 43.00mm Equivalent
Height 76.00mm 76.00mm Equivalent
Operating Temperature Range -40°C to 100°C -40°C to 125°C HARTING Exceeds Specification
Product Status Active Active Both Active
Category Heavy Duty Connectors Heavy Duty Connectors Equivalent

Engineering Selection Recommendations

Both the LAPP 79104800 and HARTING 19300160548 are active production components classified as heavy duty connectors in the hood side entry category. Selection between these parts should be based on the following engineering considerations:

LAPP 79104800 (Primary Part):

  • EPIC® HB series designation
  • Operating temperature range: -40°C to 100°C
  • Current inventory: 764 units
  • ECCN: EAR99
  • HTSUS: 8538.90.8180

HARTING 19300160548 (Substitute Part):

  • Han® B series designation
  • Operating temperature range: -40°C to 125°C (extended upper limit)
  • Current inventory: 948 units
  • RoHS3 Compliant certification
  • REACH Unaffected status
  • Moisture Sensitivity Level (MSL): 1 (Unlimited)
  • ECCN: EAR99
  • HTSUS: 8538.90.8180

The HARTING substitute provides extended temperature capability and documented RoHS3 compliance, which may be advantageous for applications requiring enhanced environmental certifications or operation in higher temperature environments. Both parts share identical mechanical interfaces, thread specifications, and ingress protection ratings.

Frequently Asked Questions (FAQ)

Q: Can HARTING 19300160548 directly replace LAPP 79104800 in existing installations?

A: Yes. Both parts are hood connectors with side entry configuration, M40 thread size, IP65 ingress protection, and identical locking clip mechanisms. Physical dimensions are within tolerance (length variance of 0.20mm is negligible for connector applications). The mechanical interface and functional performance are equivalent.

Q: What is the difference between HB16 and 16B size designations?

A: HB16 is the EPIC® HB series size designation (LAPP), while 16B is the Han® B series size designation (HARTING). These represent different manufacturer naming conventions for functionally equivalent connector sizes within their respective product lines. Both accommodate the same contact configurations and mating interfaces for M40 side entry applications.

Q: Does the HARTING part's extended temperature range (-40°C to 125°C versus -40°C to 100°C) affect compatibility?

A: No. The HARTING part's extended upper temperature limit of 125°C exceeds the LAPP specification of 100°C. This represents enhanced capability rather than incompatibility. Applications operating within the LAPP temperature range (-40°C to 100°C) will function identically with either part.

Q: Are there compliance differences between these parts?

A: The HARTING 19300160548 includes documented RoHS3 compliance and REACH Unaffected status with MSL Level 1 (Unlimited). The LAPP 79104800 specifications provided do not include these certifications. Both parts share identical ECCN (EAR99) and HTSUS (8538.90.8180) classifications.

Q: What is the packaging format for both parts?

A: Both parts are supplied in Bulk packaging format. LAPP 79104800 has 764 units in current stock, while HARTING 19300160548 has 948 units available.

Q: Are there any mechanical dimension differences that would affect installation?

A: Dimensions are functionally equivalent. Length differs by 0.20mm (93.30mm versus 93.50mm), which is within standard manufacturing tolerance for connector housings. Width and height are identical at 43.00mm and 76.00mm respectively. This variance does not affect mechanical fit or functional performance in M40 threaded applications.

Request Quote (Ships tomorrow)