SCHURTER 7010.6300.49 Equivalent & Substitute Parts

Part Overview

The SCHURTER 7010.6300.49 is a board mount axial cartridge fuse rated for 63 mA at 125 V AC/DC with fast blow response characteristics. This component is classified as obsolete, necessitating identification of functionally equivalent alternatives for ongoing design support and procurement requirements. The part operates across a temperature range of -55°C to 85°C and features a breaking capacity of 300 A at rated voltage.

Substiute Parts

7010.6300.49
SCHURTER Inc.In Stock: 9277010.6300.49 Datasheet
7010.6300.49
Current Part
7010.6300.47
SCHURTER Inc.In Stock: 12317010.6300.47 Datasheet
7010.6300.47
Similar

Key Parameters

Parameter Value
Current Rating 63 mA
Voltage Rating (AC) 125 V
Voltage Rating (DC) 125 V
Response Time Fast Blow
Mounting Type Through Hole
Package Type Cartridge, Non-Standard (Axial)
Breaking Capacity @ Rated Voltage 300 A
Melting I²t 0.0014
Operating Temperature Range -55°C ~ 85°C
Physical Dimensions 0.093" Dia x 0.315" L (2.36mm x 8.00mm)

Substitute Part Grouping Explanation

Substitution eligibility for the SCHURTER 7010.6300.49 is determined by strict equivalence across the following critical parameters:

  • Current Rating: 63 mA (exact match required)
  • Voltage Rating AC/DC: 125 V / 125 V (exact match required)
  • Response Time: Fast Blow (exact match required)
  • Mounting Type: Through Hole (exact match required)
  • Package Type: Cartridge, Non-Standard (Axial) (exact match required)
  • Breaking Capacity: 300 A at rated voltage (exact match required)
  • Melting I²t: 0.0014 (exact match required)
  • Physical Dimensions: 0.093" Dia x 0.315" L (exact match required)
  • Operating Temperature Range: -55°C ~ 85°C (exact match required)

Parts meeting all specified parameters are classified as direct equivalents and may be substituted without circuit redesign or board layout modification.

Parameter Comparison

Parameter 7010.6300.49 (Main Part) 7010.6300.47 (Substitute) Match Status
Manufacturer SCHURTER Inc. SCHURTER Inc. Identical
Current Rating (Amps) 63 mA 63 mA Identical
Voltage Rating - AC 125 V 125 V Identical
Voltage Rating - DC 125 V 125 V Identical
Response Time Fast Blow Fast Blow Identical
Mounting Type Through Hole Through Hole Identical
Fuse Type Board Mount (Cartridge Style Excluded) Board Mount (Cartridge Style Excluded) Identical
Package / Case Cartridge, Non-Standard (Axial) Cartridge, Non-Standard (Axial) Identical
Breaking Capacity @ Rated Voltage 300 A 300 A Identical
Melting I²t 0.0014 0.0014 Identical
Operating Temperature -55°C ~ 85°C -55°C ~ 85°C Identical
Size / Dimension 0.093" Dia x 0.315" L (2.36mm x 8.00mm) 0.093" Dia x 0.315" L (2.36mm x 8.00mm) Identical
Product Status Obsolete Active Substitute is Active
RoHS Status Not specified ROHS3 Compliant Substitute has compliance documentation
REACH Status Not specified REACH Unaffected Substitute has compliance documentation

Engineering Selection Recommendations

The SCHURTER 7010.6300.47 is a direct functional equivalent to the obsolete 7010.6300.49. All electrical parameters, mechanical dimensions, and thermal characteristics are identical across both parts. The substitute part carries Active product status, ensuring continued availability and supply chain stability.

The 7010.6300.47 provides additional compliance documentation, including ROHS3 compliance and REACH unaffected status, which may be required for applications subject to environmental regulations. Both parts are manufactured by SCHURTER Inc. within the same 172321 series, confirming design continuity.

For applications currently utilizing the 7010.6300.49, direct substitution with the 7010.6300.47 requires no circuit modifications, board layout changes, or performance re-qualification. The parts are pin-compatible and functionally interchangeable.

Frequently Asked Questions (FAQ)

Q: Can the 7010.6300.47 be used as a direct replacement for the 7010.6300.49?

A: Yes. All electrical ratings, mechanical dimensions, response characteristics, and thermal operating ranges are identical. Direct substitution is supported without circuit or layout modifications.

Q: What is the primary reason for substituting the 7010.6300.49?

A: The 7010.6300.49 is classified as obsolete. The 7010.6300.47 is an active product with equivalent specifications and assured long-term availability.

Q: Are there any compliance differences between these parts?

A: The 7010.6300.47 includes documented ROHS3 compliance and REACH unaffected status. Compliance documentation for the 7010.6300.49 was not provided in the available specifications.

Q: Do these parts have identical physical dimensions?

A: Yes. Both parts measure 0.093" diameter by 0.315" length (2.36mm x 8.00mm) and use identical through-hole axial cartridge packaging.

Q: What is the current rating for both parts?

A: Both parts are rated for 63 mA at 125 V AC and 125 V DC with fast blow response characteristics.

Q: Are there any inventory considerations?

A: The 7010.6300.47 has 1154 pieces in stock, compared to 834 pieces for the obsolete 7010.6300.49. The substitute part offers greater inventory availability.

Q: What is the operating temperature range for these fuses?

A: Both parts operate across -55°C to 85°C, supporting applications across industrial and commercial temperature environments.

Q: Is the breaking capacity the same for both parts?

A: Yes. Both parts have a breaking capacity of 300 A at rated voltage with identical melting I²t values of 0.0014.

Request Quote (Ships tomorrow)