Amphenol ICC 67274-012 Equivalent & Substitute Parts

Part Overview

The Amphenol ICC 67274-012 is a rectangular connector header for through-hole mounting with 24 positions arranged in 2 rows at 0.100" (2.54mm) pitch. This shrouded, push-pull fastened connector is designed for board-to-board or cable applications with solder termination. The part is currently obsolete, making equivalent substitutes from active product lines necessary for ongoing design support and procurement.

Substiute Parts

67274-012
Amphenol ICC (FCI)In Stock: 98667274-012 Datasheet
67274-012
Current Part
102567-2
TE Connectivity AMP ConnectorsIn Stock: 1484102567-2 Datasheet
102567-2
MFR Recommended
102692-2
TE Connectivity AMP ConnectorsIn Stock: 1194102692-2 Datasheet
102692-2
MFR Recommended
5-102567-2
TE Connectivity AMP ConnectorsIn Stock: 17585-102567-2 Datasheet
5-102567-2
MFR Recommended
5-534257-7
TE Connectivity AMP ConnectorsIn Stock: 9385-534257-7 Datasheet
5-534257-7
MFR Recommended
5-534978-4
TE Connectivity AMP ConnectorsIn Stock: 9125-534978-4 Datasheet
5-534978-4
MFR Recommended
534257-7
TE Connectivity AMP ConnectorsIn Stock: 707534257-7 Datasheet
534257-7
MFR Recommended
534978-4
TE Connectivity AMP ConnectorsIn Stock: 762534978-4 Datasheet
534978-4
MFR Recommended

Key Parameters

Parameter Value
Connector Type Header
Contact Type Male Pin
Number of Positions 24
Number of Rows 2
Pitch - Mating 0.100" (2.54mm)
Row Spacing - Mating 0.100" (2.54mm)
Shrouding Shrouded - 4 Wall
Mounting Type Through Hole
Termination Solder
Fastening Type Push-Pull
Contact Shape Square
Insulation Height 0.550" (13.97mm)
Material Flammability Rating UL94 V-0
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution for the 67274-012 is based on strict equivalence of the following critical parameters:

  • Connector type (Header), contact type (Male Pin), and fastening mechanism (Push-Pull)
  • Electrical configuration: 24 positions in 2 rows at 0.100" (2.54mm) pitch with 0.100" row spacing
  • Physical form factor: Shrouded 4-wall construction, through-hole mounting, solder termination
  • Mechanical compatibility: Square contact shape, 0.550" insulation height
  • Environmental rating: UL94 V-0 flammability, MSL 1

All substitute parts listed maintain these core parameters. Variations in contact finish specifications, post material composition, and RoHS/REACH compliance status do not affect mechanical or electrical interchangeability for standard applications.

Parameter Comparison

Parameter 67274-012 (Amphenol ICC) 102567-2 (TE) 102692-2 (TE) 5-102567-2 (TE) 5-534257-7 (TE) 5-534978-4 (TE) 534257-7 (TE) 534978-4 (TE)
Manufacturer Amphenol ICC (FCI) TE Connectivity AMP TE Connectivity AMP TE Connectivity AMP TE Connectivity AMP TE Connectivity AMP TE Connectivity AMP TE Connectivity AMP
Product Status Obsolete Active Active Active Active Active Active Active
Series AMPMODU Mod II AMPMODU Mod II AMPMODU Mod II AMPMODU Mod II AMPMODU Mod II AMPMODU Mod II AMPMODU Mod II
Connector Type Header Header Header Header Header Header Header Header
Contact Type Male Pin Male Pin Male Pin Male Pin Male Pin Male Pin Male Pin Male Pin
Number of Positions 24 24 24 24 24 24 24 24
Number of Rows 2 2 2 2 2 2 2 2
Pitch - Mating 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm)
Row Spacing - Mating 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm) 0.100" (2.54mm)
Shrouding Shrouded - 4 Wall Shrouded - 4 Wall Shrouded - 4 Wall Shrouded - 4 Wall Shrouded - 4 Wall Shrouded - 4 Wall Shrouded - 4 Wall Shrouded - 4 Wall
Mounting Type Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole Through Hole
Termination Solder Solder Solder Solder Solder Solder Solder Solder
Fastening Type Push-Pull Push-Pull Push-Pull Push-Pull Push-Pull Push-Pull Push-Pull Push-Pull
Contact Shape Square Square Square Square Square Square Square Square
Insulation Height 0.550" (13.97mm) 0.550" (13.97mm) 0.550" (13.97mm) 0.550" (13.97mm) 0.550" (13.97mm) 0.550" (13.97mm) 0.550" (13.97mm) 0.550" (13.97mm)
Contact Finish - Mating Gold or Gold, GXT™ Gold Gold Gold Gold Gold Gold Gold
Contact Finish Thickness - Mating 15.0µin (0.38µm) 15.0µin (0.38µm) 30.0µin (0.76µm) 15.0µin (0.38µm) 15.0µin (0.38µm) 30.0µin (0.76µm) 15.0µin (0.38µm) 30.0µin (0.76µm)
Contact Material Phosphor Bronze Copper Alloy Copper Alloy Copper Alloy Copper Alloy Copper Alloy Copper Alloy Copper Alloy
Insulation Material Resin Thermoplastic, Glass Filled Thermoplastic, Glass Filled Thermoplastic, Glass Filled Thermoplastic Thermoplastic Thermoplastic Thermoplastic
Material Flammability Rating UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0 UL94 V-0
Insulation Color Natural Black Black Black Black Black Black Black
Current Rating (Amps) 3A 2A 3A 3A 3A 3A 3A
Voltage Rating 250VAC 250VAC 250VAC 250VAC 250VAC 250VAC 250VAC
Operating Temperature -65°C ~ 105°C -65°C ~ 105°C -65°C ~ 105°C -65°C ~ 105°C -65°C ~ 105°C -65°C ~ 105°C -65°C ~ 105°C
RoHS Status RoHS non-compliant RoHS non-compliant RoHS non-compliant ROHS3 Compliant RoHS non-compliant RoHS Compliant RoHS non-compliant RoHS non-compliant
REACH Status REACH Unaffected REACH Affected REACH Affected REACH Unaffected REACH Affected REACH Unaffected REACH Affected REACH Affected
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99 EAR99 EAR99 EAR99 EAR99 EAR99 EAR99
HTSUS 8536.69.4040 8536.69.4040 8536.69.4040 8536.69.4040 8536.69.4040 8536.69.4040 8536.69.4040 8536.69.4040

Engineering Selection Recommendations

All listed substitute parts are mechanically and electrically interchangeable with the 67274-012 based on core connector specifications. Selection among substitutes should be based on the following criteria:

For RoHS3 Compliance Requirements: Part 5-102567-2 is the only option with ROHS3 Compliant status and REACH Unaffected designation, making it suitable for applications with strict environmental compliance mandates.

For RoHS Compliance (General): Part 5-534978-4 carries RoHS Compliant status with REACH Unaffected status, providing an alternative for RoHS-regulated applications.

For Standard Applications Without Compliance Constraints: Parts 102567-2, 102692-2, 5-534257-7, 534257-7, and 534978-4 are all active products suitable for general use. These parts differ in contact finish thickness (15.0µin or 30.0µin), post material composition (Tin, Tin-Lead), and insulation material formulation (Thermoplastic or Thermoplastic, Glass Filled).

Current Rating Consideration: Part 102692-2 is rated for 2A maximum current, while all other substitutes are rated for 3A. Applications requiring 3A or higher should exclude 102692-2.

Packaging: All substitute parts are supplied in tube packaging, consistent with standard connector distribution formats.

Frequently Asked Questions (FAQ)

Q: Are all listed parts direct mechanical replacements for the 67274-012?

A: Yes. All substitute parts maintain identical connector type, contact configuration, pitch spacing, shrouding design, mounting method, and termination type. They are mechanically interchangeable without PCB redesign.

Q: What is the difference between parts with 15.0µin and 30.0µin contact finish thickness?

A: Contact finish thickness affects durability and wear resistance during mating cycles. The 30.0µin thickness (102692-2, 5-534978-4, 534978-4) provides enhanced durability for high-cycle applications. The 15.0µin thickness (102567-2, 5-102567-2, 5-534257-7, 534257-7) is standard for general applications.

Q: What is the significance of Tin versus Tin-Lead post finish?

A: Post finish material affects solder joint formation during PCB assembly. Tin-Lead (102567-2, 102692-2, 534257-7, 534978-4) is traditional and widely compatible with standard solder processes. Tin (5-102567-2, 5-534257-7, 5-534978-4) is lead-free and required for RoHS-compliant applications.

Q: Which substitute should I select for new designs?

A: For new designs, prioritize active products with current compliance status. Part 5-102567-2 is recommended for RoHS3-regulated applications. Part 5-534978-4 is recommended for RoHS-regulated applications. For applications without compliance constraints, any active substitute is acceptable based on availability and cost.

Q: Does insulation material (Thermoplastic versus Thermoplastic, Glass Filled) affect electrical performance?

A: Both materials meet UL94 V-0 flammability requirements and maintain equivalent electrical properties for standard applications. Glass-filled formulations (102567-2, 102692-2, 5-102567-2) provide slightly enhanced mechanical rigidity. Material selection should be based on application-specific mechanical requirements and supplier availability.

Q: Are there any restrictions on mixing substitute parts in the same assembly?

A: No. All substitute parts are electrically and mechanically equivalent. Mixed usage within a single assembly is permissible without functional impact.

Q: What is the inventory status of these substitutes?

A: All substitute parts are listed as active products with current stock availability ranging from 607 to 1668 pieces. Verify current inventory with your supplier before finalizing procurement.