API Delevan 6498-036 Equivalent & Substitute Parts

Part Overview

The API Delevan 6498-036 is a laminated core power transformer rated at 175VA with dual primary and secondary windings. The device supports input voltages of 115V or 230V and delivers output configurations of 18V parallel (9.6A) or 36V series (4.8A). This transformer features chassis mount construction with solder and quick connect termination options, providing 4000Vrms isolation.

The 6498-036 is classified as obsolete. Locating active production equivalents is necessary to ensure continued component availability, supply chain reliability, and access to current manufacturing standards and compliance certifications.

Substiute Parts

6498-036
API Delevan Inc.In Stock: 7596498-036 Datasheet
6498-036
Current Part
6498R-036
API Delevan Inc.In Stock: 9926498R-036 Datasheet
6498R-036
Direct

Key Parameters

Parameter Value
Power Rating 175VA
Primary Voltage Options 115V, 230V
Secondary Voltage - Parallel Configuration 18V
Secondary Voltage - Series Configuration 36V
Maximum Output Current - Parallel 9.6A
Maximum Output Current - Series 4.8A
Core Type Laminated
Primary Windings Dual
Secondary Windings Dual
Center Tap No
Mounting Type Chassis Mount
Termination Style Solder, Quick Connect
Isolation Voltage 4000Vrms
Physical Dimensions (L x W) 79.38mm x 73.03mm
Height - Seated Maximum 95.25mm

Substitute Part Grouping Explanation

Substitution of the obsolete 6498-036 with an active equivalent is based on electrical and mechanical parameter matching. The substitute part must satisfy all of the following criteria:

Electrical Parameters (Required Match):

  • Power rating: 175VA
  • Primary voltage options: 115V and 230V
  • Secondary voltage configurations: 18V parallel and 36V series
  • Output current capacity: 9.6A parallel and 4.8A series
  • Isolation voltage: 4000Vrms
  • Winding configuration: Dual primary and dual secondary
  • No center tap

Mechanical Parameters (Required Match):

  • Core type: Laminated
  • Mounting type: Chassis mount
  • Termination style: Solder and quick connect
  • Physical dimensions: 79.38mm L x 73.03mm W
  • Height seated maximum: 95.25mm

The 6498R-036 meets all electrical and mechanical requirements and is manufactured by the same supplier, API Delevan Inc., ensuring design and performance continuity.

Parameter Comparison

Parameter 6498-036 (Obsolete) 6498R-036 (Active) Match Status
Manufacturer API Delevan Inc. API Delevan Inc. Identical
Power Rating 175VA 175VA Identical
Primary Voltage 115V, 230V 115V, 230V Identical
Secondary Voltage - Parallel 18V 18V Identical
Secondary Voltage - Series 36V 36V Identical
Output Current - Parallel 9.6A 9.6A Identical
Output Current - Series 4.8A 4.8A Identical
Core Type Laminated Laminated Identical
Primary Windings Dual Dual Identical
Secondary Windings Dual Dual Identical
Center Tap No No Identical
Mounting Type Chassis Mount Chassis Mount Identical
Termination Style Solder, Quick Connect Solder, Quick Connect Identical
Isolation Voltage 4000Vrms 4000Vrms Identical
Dimensions (L x W) 79.38mm x 73.03mm 79.38mm x 73.03mm Identical
Height - Seated Maximum 95.25mm 95.25mm Identical
Product Status Obsolete Active Substitute is active
RoHS Compliance Non-compliant ROHS3 Compliant Substitute meets current standards
REACH Status Not specified REACH Unaffected Substitute meets current standards

Engineering Selection Recommendations

The 6498R-036 is the direct active equivalent of the obsolete 6498-036. Both components are manufactured by API Delevan Inc. and share identical electrical and mechanical specifications across all critical parameters: power rating, voltage configurations, current capacity, core type, winding configuration, mounting, termination, isolation voltage, and physical dimensions.

The 6498R-036 offers additional advantages in terms of product lifecycle and regulatory compliance. The substitute is currently in active production status, ensuring reliable supply availability. The 6498R-036 is ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory requirements, whereas the 6498-036 is non-compliant with modern standards.

For new designs, maintenance applications, or component replacement requiring a 175VA laminated core transformer with dual primary and secondary windings, the 6498R-036 is the appropriate selection. The identical parameter set ensures direct functional and mechanical compatibility without design modification.

Frequently Asked Questions (FAQ)

Q: Can the 6498R-036 be used as a direct replacement for the 6498-036?

A: Yes. The 6498R-036 is electrically and mechanically identical to the 6498-036 across all specified parameters. Both transformers deliver 175VA power, support 115V/230V primary inputs, provide 18V parallel or 36V series secondary outputs, and feature identical mounting and termination configurations. Physical dimensions and isolation voltage are also identical.

Q: What is the difference between the 6498-036 and 6498R-036?

A: The primary differences are product status and compliance certifications. The 6498-036 is obsolete and non-compliant with RoHS standards. The 6498R-036 is in active production, ROHS3 compliant, and REACH unaffected. All electrical and mechanical specifications are identical.

Q: Are there any compatibility concerns when substituting the 6498R-036 for the 6498-036?

A: No compatibility concerns exist. The transformers are identical in electrical performance, power rating, voltage configurations, current capacity, core construction, winding arrangement, mounting type, termination style, isolation voltage, and physical dimensions. Direct substitution is supported without circuit or mechanical modifications.

Q: What are the output current ratings for each voltage configuration?

A: In parallel configuration (18V secondary), the maximum output current is 9.6A. In series configuration (36V secondary), the maximum output current is 4.8A. Both the 6498-036 and 6498R-036 support these identical ratings.

Q: What mounting and termination options are available?

A: Both transformers feature chassis mount construction with dual termination options: solder and quick connect. This allows flexibility in circuit board integration and field installation methods.

Q: Is the 6498R-036 suitable for applications requiring RoHS compliance?

A: Yes. The 6498R-036 is ROHS3 compliant, making it suitable for applications and markets requiring adherence to current environmental and hazardous substance restrictions. The obsolete 6498-036 does not meet these standards.

Request Quote (Ships tomorrow)