API Delevan 6446-024 Equivalent & Substitute Parts

Part Overview

The API Delevan 6446-024 is a 20VA laminated core power transformer with dual primary and secondary windings, designed for through-hole mounting applications. The primary winding supports 115V or 230V input, while the secondary winding provides parallel 12V or series 24V output configurations. This part is classified as obsolete, making identification of suitable substitute components essential for ongoing system support and new design implementations.

Substiute Parts

6446-024
API Delevan Inc.In Stock: 7956446-024 Datasheet
6446-024
Current Part
6446R-024
API Delevan Inc.In Stock: 8216446R-024 Datasheet
6446R-024
Direct

Key Parameters

Parameter Specification
Manufacturer Part Number 6446-024
Manufacturer API Delevan Inc.
Series 6446
Power Rating 20VA
Core Type Laminated
Primary Voltage Options 115V, 230V
Secondary Voltage (Parallel) 12V
Secondary Voltage (Series) 24V
Maximum Output Current (Parallel) 1.66A
Maximum Output Current (Series) 830mA
Mounting Type Through Hole
Termination Style PC Pin
Isolation Voltage 4000Vrms
Physical Dimensions 57.15mm L × 47.63mm W × 36.50mm H
Weight 0.9 lb (408.23 g)
Product Status Obsolete

Substitute Part Grouping Explanation

Substitute components for the 6446-024 are identified based on electrical and mechanical parameter equivalence. The critical parameters determining substitution eligibility are:

  • Power rating (20VA)
  • Core type (laminated)
  • Primary voltage configuration (115V, 230V dual winding)
  • Secondary voltage output (parallel 12V, series 24V dual winding)
  • Output current capacity (parallel 1.66A, series 830mA)
  • Mounting type (through hole)
  • Termination style (PC pin)
  • Isolation voltage (4000Vrms)
  • Physical envelope (57.15mm L × 47.63mm W × 36.50mm H)

The 6446R-024 qualifies as a direct substitute, maintaining identical electrical specifications and mechanical form factor while offering improved product status and regulatory compliance.

Parameter Comparison

Parameter 6446-024 (Main Part) 6446R-024 (Substitute)
Manufacturer API Delevan Inc. API Delevan Inc.
Power Rating 20VA 20VA
Core Type Laminated Laminated
Primary Voltage 115V, 230V 115V, 230V
Secondary Voltage (Parallel) 12V 12V
Secondary Voltage (Series) 24V 24V
Output Current - Parallel 1.66A 1.66A
Output Current - Series 830mA 830mA
Primary Windings Dual Dual
Secondary Windings Dual Dual
Center Tap No No
Mounting Type Through Hole Through Hole
Termination Style PC Pin PC Pin
Isolation Voltage 4000Vrms 4000Vrms
Dimensions 57.15mm L × 47.63mm W × 36.50mm H 57.15mm L × 47.63mm W × 36.50mm H
Weight 0.9 lb (408.23 g) 0.9 lb (408.23 g)
Product Status Obsolete Active
RoHS Status RoHS non-compliant ROHS3 Compliant

Engineering Selection Recommendations

The 6446R-024 is the direct equivalent substitute for the obsolete 6446-024. Both components share identical electrical performance specifications and mechanical form factors, ensuring pin-for-pin and footprint compatibility in existing circuit designs.

The primary distinction between these components is product lifecycle status and regulatory compliance. The 6446-024 is obsolete and RoHS non-compliant, while the 6446R-024 maintains active production status and meets ROHS3 compliance requirements. For new designs and ongoing system support, the 6446R-024 is the appropriate selection.

Both components maintain equivalent isolation voltage (4000Vrms), power capacity (20VA), and output current specifications across parallel and series winding configurations. No circuit redesign or performance trade-offs are required when transitioning from the 6446-024 to the 6446R-024.

Frequently Asked Questions (FAQ)

Q: Can the 6446R-024 be used as a direct replacement for the 6446-024 in existing applications?

A: Yes. The 6446R-024 provides identical electrical and mechanical specifications. Pin configuration, footprint, and performance characteristics are equivalent, enabling direct substitution without circuit modification.

Q: What is the primary advantage of selecting the 6446R-024 over the 6446-024?

A: The 6446R-024 is an active product with ROHS3 compliance, whereas the 6446-024 is obsolete and RoHS non-compliant. For new designs and long-term availability, the 6446R-024 is the recommended choice.

Q: Are the output current ratings identical between these components?

A: Yes. Both the 6446-024 and 6446R-024 deliver 1.66A maximum output current in parallel winding configuration and 830mA in series winding configuration.

Q: Do both components support the same primary voltage inputs?

A: Yes. Both components feature dual primary windings supporting 115V or 230V input selection.

Q: Is the physical footprint identical for PCB mounting?

A: Yes. Both components share identical dimensions (57.15mm L × 47.63mm W × 36.50mm H) and through-hole PC pin termination, ensuring identical PCB layout compatibility.

Q: What is the isolation voltage rating for these transformers?

A: Both components provide 4000Vrms isolation voltage between primary and secondary windings.

Request Quote (Ships tomorrow)