TE Connectivity 644565-4 Rectangular Connector Equivalent & Substitute Parts

Part Overview

The TE Connectivity 644565-4 is a 4-position rectangular receptacle connector from the MTA-100 series, designed for IDC (Insulation Displacement Contact) termination with 28 AWG discrete or ribbon cable. This connector features tin-lead contact finish, feed-through capability, and a locking ramp fastening mechanism with right-angle or free-hanging in-line mounting options.

The 644565-4 is classified as obsolete. Identifying equivalent and substitute parts is necessary to maintain design continuity, ensure supply chain availability, and support ongoing production and field service requirements for systems utilizing this connector type.

Substiute Parts

644565-4
TE Connectivity AMP ConnectorsIn Stock: 1041644565-4 Datasheet
644565-4
Current Part
3-644565-4
TE Connectivity AMP ConnectorsIn Stock: 12283-644565-4 Datasheet
3-644565-4
Direct

Key Parameters

Parameter Value
Connector Type Receptacle
Number of Positions 4
Pitch 0.100" (2.54mm)
Cable Termination Method IDC
Wire Gauge 28 AWG
Contact Type Female Socket
Mounting Type Free Hanging (In-Line), Right Angle
Fastening Type Locking Ramp
Series MTA-100
Contact Finish Tin-Lead
Features Feed Through

Substitute Part Grouping Explanation

Substitution eligibility for the 644565-4 is determined by strict equivalence across the following critical parameters:

Mandatory Matching Parameters:

  • Connector type (Receptacle)
  • Number of positions (4)
  • Pitch specification (0.100" / 2.54mm)
  • Cable termination method (IDC)
  • Wire gauge compatibility (28 AWG)
  • Contact type (Female Socket)
  • Mounting configuration (Free Hanging In-Line, Right Angle)
  • Fastening mechanism (Locking Ramp)
  • Series designation (MTA-100)
  • Feed-through capability

The substitute part 3-644565-4 maintains full electrical and mechanical compatibility with the original 644565-4 across all specified parameters. The primary distinction between these parts is the contact finish specification and product status classification.

Parameter Comparison

Parameter 644565-4 (Main Part) 3-644565-4 (Substitute)
Manufacturer TE Connectivity AMP Connectors TE Connectivity AMP Connectors
Series MTA-100 MTA-100
Connector Type Receptacle Receptacle
Number of Positions 4 4
Pitch 0.100" (2.54mm) 0.100" (2.54mm)
Contact Type Female Socket Female Socket
Number of Rows 1 1
Mounting Type Free Hanging (In-Line), Right Angle Free Hanging (In-Line), Right Angle
Fastening Type Locking Ramp Locking Ramp
Cable Termination IDC IDC
Wire Type Discrete or Ribbon Cable Discrete or Ribbon Cable
Wire Gauge 28 AWG 28 AWG
Features Feed Through Feed Through
Contact Finish Tin-Lead Tin
Contact Finish Thickness 80.0µin (2.03µm) 80.0µin (2.03µm)
Color Green Green
Product Status Obsolete Active
RoHS Status RoHS non-compliant RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99
HTSUS 8536.69.8000 8536.69.8000

Engineering Selection Recommendations

Primary Substitute: 3-644565-4

The 3-644565-4 is the direct substitute for the obsolete 644565-4. Both parts share identical electrical and mechanical specifications across all critical connector parameters, including pitch, position count, termination method, wire gauge, and mounting configuration.

Compliance Considerations:

The 3-644565-4 holds active product status and carries RoHS compliance certification, whereas the 644565-4 is classified as obsolete and RoHS non-compliant. For new designs, system upgrades, or applications subject to RoHS regulatory requirements, the 3-644565-4 is the appropriate selection.

Contact Finish Distinction:

The 644565-4 specifies tin-lead contact finish, while the 3-644565-4 specifies tin contact finish. Both finishes maintain the same thickness specification of 80.0µin (2.03µm). The tin finish in the 3-644565-4 aligns with modern lead-free manufacturing standards and RoHS compliance requirements.

Supply Chain Status:

The 3-644565-4 maintains active inventory status with 1122 pieces available, compared to the 644565-4 with 971 pieces in stock. For ongoing procurement and long-term availability, the 3-644565-4 is the recommended selection.

Frequently Asked Questions (FAQ)

Q: Can the 3-644565-4 be used as a direct replacement for the 644565-4 in existing assemblies?

A: Yes. The 3-644565-4 maintains full electrical and mechanical compatibility with the 644565-4 across all connector specifications, including pitch, position count, IDC termination method, 28 AWG wire gauge, mounting type, and fastening mechanism. Both parts are from the MTA-100 series and feature identical feed-through capability.

Q: What is the difference between the tin-lead finish on the 644565-4 and the tin finish on the 3-644565-4?

A: The 644565-4 uses tin-lead contact finish, while the 3-644565-4 uses tin contact finish. Both finishes are applied to the same thickness of 80.0µin (2.03µm). The tin finish on the 3-644565-4 reflects current manufacturing standards and supports RoHS compliance requirements.

Q: Why is the 644565-4 classified as obsolete?

A: The 644565-4 is listed as obsolete in the product lifecycle. The 3-644565-4 is the active equivalent part that replaces it. For new designs and ongoing production, the 3-644565-4 should be specified.

Q: Are there any packaging differences between these parts?

A: The 644565-4 packaging specification is not defined in the available data. The 3-644565-4 is supplied in bulk packaging. Confirm packaging requirements with your procurement specifications.

Q: Does the RoHS compliance difference affect compatibility?

A: No. RoHS compliance is a regulatory and manufacturing standard classification, not a functional or electrical parameter. The 3-644565-4 is RoHS compliant, making it suitable for applications and markets with RoHS requirements. The electrical and mechanical performance of both parts is equivalent.

Q: Can I use these connectors with both discrete and ribbon cable?

A: Yes. Both the 644565-4 and 3-644565-4 support discrete or ribbon cable termination via IDC method at 28 AWG wire gauge.

Q: What does "Feed Through" mean for these connectors?

A: Feed Through indicates that the connector supports pass-through signal routing, allowing signals to be transmitted through the connector body while maintaining the connection interface.