6445-012 Laminated Power Transformer Equivalent & Substitute Parts

Part Overview

The 6445-012 is a 10VA laminated core power transformer manufactured by API Delevan Inc., designed for through-hole mounting applications. It features dual primary windings (115V, 230V) and dual secondary windings (parallel 6.3V/1.6A or series 12.6V/800mA configuration). The part is currently classified as obsolete, making identification of suitable substitute components essential for ongoing system support and new design implementations.

Substiute Parts

6445-012
API Delevan Inc.In Stock: 11246445-012 Datasheet
6445-012
Current Part
6445R-012
API Delevan Inc.In Stock: 11756445R-012 Datasheet
6445R-012
Direct

Key Parameters

Parameter Specification
Manufacturer Part Number 6445-012
Manufacturer API Delevan Inc.
Series 6445
Power Rating 10VA
Core Type Laminated
Primary Voltage Options 115V, 230V
Secondary Voltage (Parallel) 6.3V
Secondary Voltage (Series) 12.6V
Secondary Current (Parallel) 1.6A
Secondary Current (Series) 800mA
Mounting Type Through Hole
Termination Style PC Pin
Isolation Voltage 4000Vrms
Dimensions (L x W) 47.63mm x 39.67mm
Height (Seated Max) 36.50mm
Weight 0.53 lb (240.4 g)

Substitute Part Grouping Explanation

Substitution eligibility for the 6445-012 is determined by strict equivalence across the following critical parameters:

  • Power rating: 10VA
  • Core type: Laminated
  • Primary winding configuration: Dual (115V, 230V)
  • Secondary winding configuration: Dual (6.3V parallel / 12.6V series)
  • Output current capacity: 1.6A parallel / 800mA series
  • Isolation voltage: 4000Vrms
  • Mounting type: Through Hole
  • Termination style: PC Pin
  • Physical dimensions: 47.63mm L x 39.67mm W x 36.50mm H (seated max)

The 6445R-012 qualifies as a direct substitute based on complete parameter alignment across all electrical and mechanical specifications.

Parameter Comparison

Parameter 6445-012 (Main Part) 6445R-012 (Substitute)
Manufacturer Part Number 6445-012 6445R-012
Manufacturer API Delevan Inc. API Delevan Inc.
Series 6445 6445R
Product Status Obsolete Active
Power Rating 10VA 10VA
Core Type Laminated Laminated
Primary Voltage Options 115V, 230V 115V, 230V
Secondary Voltage (Parallel) 6.3V 6.3V
Secondary Voltage (Series) 12.6V 12.6V
Secondary Current (Parallel) 1.6A 1.6A
Secondary Current (Series) 800mA 800mA
Primary Windings Dual Dual
Secondary Windings Dual Dual
Center Tap No No
Mounting Type Through Hole Through Hole
Termination Style PC Pin PC Pin
Isolation Voltage 4000Vrms 4000Vrms
Dimensions (L x W) 47.63mm x 39.67mm 47.63mm x 39.67mm
Height (Seated Max) 36.50mm 36.50mm
Weight 0.53 lb (240.4 g) 0.53 lb (240.4 g)
RoHS Status RoHS non-compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS Code 8504.31.4035 8504.31.4035

Engineering Selection Recommendations

The 6445R-012 is the direct equivalent substitute for the obsolete 6445-012. Both parts maintain identical electrical performance and physical form factor, ensuring drop-in compatibility for through-hole PCB applications.

The primary distinction between the two parts is product status and regulatory compliance. The 6445-012 is obsolete and RoHS non-compliant, while the 6445R-012 is an active production part with ROHS3 compliance. For new designs or systems requiring regulatory adherence to RoHS3 standards, the 6445R-012 is the appropriate selection. For legacy system maintenance where the original 6445-012 is no longer available, the 6445R-012 provides full functional and mechanical equivalence.

Both parts share identical REACH and ECCN classifications, confirming regulatory parity across export and environmental compliance frameworks.

Frequently Asked Questions (FAQ)

Q: Can the 6445R-012 be used as a direct replacement for the 6445-012 in existing designs?

A: Yes. The 6445R-012 is electrically and mechanically identical to the 6445-012. All voltage ratings, current capacities, winding configurations, isolation specifications, and physical dimensions are equivalent. Through-hole mounting and PC pin termination are identical, enabling direct PCB substitution.

Q: What is the primary reason to transition from 6445-012 to 6445R-012?

A: The 6445-012 is classified as obsolete and is RoHS non-compliant. The 6445R-012 is an active production part with ROHS3 compliance, ensuring long-term availability and regulatory alignment for new designs and system updates.

Q: Are there any electrical performance differences between these parts?

A: No. Both parts deliver 10VA power capacity with identical primary voltage options (115V, 230V), secondary voltage configurations (6.3V parallel / 12.6V series), output current ratings (1.6A parallel / 800mA series), and 4000Vrms isolation voltage.

Q: Do these transformers have the same physical footprint?

A: Yes. Both parts have identical dimensions of 47.63mm length x 39.67mm width with a maximum seated height of 36.50mm, and both weigh 0.53 lb (240.4 g). They are suitable for the same through-hole PCB layouts.

Q: What certifications apply to both parts?

A: Both parts share identical REACH and ECCN (EAR99) classifications. The 6445R-012 additionally carries ROHS3 compliance, while the 6445-012 is RoHS non-compliant.

Request Quote (Ships tomorrow)