TE Connectivity 644462-4 Rectangular Connector Equivalent & Substitute Parts

Part Overview

The TE Connectivity 644462-4 is a 4-position rectangular receptacle connector from the MTA-156 series, designed for IDC (Insulation Displacement Contact) termination with 20 AWG discrete or ribbon cable. This connector features a closed end design with polarizing key, tin-lead contact finish, and yellow housing. The part is currently active in production with 704 units in stock.

Substitute parts are identified when equivalent electrical and mechanical specifications are maintained across connector position count, pitch, mounting configuration, cable termination method, and wire gauge compatibility. Alternative part numbers may offer different packaging formats, contact finish materials, or compliance certifications while preserving functional interchangeability.

Substiute Parts

644462-4
TE Connectivity AMP ConnectorsIn Stock: 769644462-4 Datasheet
644462-4
Current Part
3-644462-4
TE Connectivity AMP ConnectorsIn Stock: 10743-644462-4 Datasheet
3-644462-4
Direct

Key Parameters

Parameter Value Specification Basis
Connector Type Receptacle Functional role in mated pair
Number of Positions 4 Contact count and circuit capacity
Pitch 0.156" (3.96mm) Contact spacing and mating compatibility
Cable Termination IDC Termination method and tooling requirement
Wire Gauge 20 AWG Current capacity and conductor compatibility
Mounting Type Free Hanging (In-Line) Installation configuration
Series MTA-156 Product family and design standard
Contact Finish Thickness 80.0µin (2.03µm) Durability and electrical performance

Substitute Part Grouping Explanation

Substitution eligibility for the TE Connectivity 644462-4 is determined by strict equivalence across the following critical parameters:

Mandatory Matching Parameters:

  • Connector type (Receptacle)
  • Number of positions (4)
  • Pitch specification (0.156" / 3.96mm)
  • Cable termination method (IDC)
  • Wire gauge rating (20 AWG)
  • Mounting configuration (Free Hanging In-Line)
  • Series designation (MTA-156)
  • Contact finish thickness (80.0µin / 2.03µm)

Variable Parameters Permitting Substitution:

  • Contact finish material (Tin-Lead vs. Tin)
  • Packaging format (standard vs. bulk)
  • RoHS compliance status
  • Inventory availability

The substitute part 3-644462-4 maintains all mandatory parameters while differing in contact finish composition (Tin instead of Tin-Lead) and RoHS compliance certification. Both parts share identical mechanical dimensions, electrical ratings, and functional performance characteristics within the MTA-156 connector family.

Parameter Comparison

Parameter 644462-4 (Main Part) 3-644462-4 (Substitute) Compatibility
Manufacturer TE Connectivity AMP Connectors TE Connectivity AMP Connectors Identical
Series MTA-156 MTA-156 Identical
Connector Type Receptacle Receptacle Identical
Contact Type Female Socket Female Socket Identical
Number of Positions 4 4 Identical
Pitch 0.156" (3.96mm) 0.156" (3.96mm) Identical
Number of Rows 1 1 Identical
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line) Identical
Cable Termination IDC IDC Identical
Wire Type Discrete or Ribbon Cable Discrete or Ribbon Cable Identical
Wire Gauge 20 AWG 20 AWG Identical
Features Closed End, Polarizing Key Closed End, Polarizing Key Identical
Contact Finish Tin-Lead Tin Different material, equivalent performance
Contact Finish Thickness 80.0µin (2.03µm) 80.0µin (2.03µm) Identical
Color Yellow Yellow Identical
Product Status Active Active Identical
RoHS Status RoHS non-compliant ROHS3 Compliant Different compliance level
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) Identical
ECCN EAR99 EAR99 Identical
HTSUS 8536.69.8000 8536.69.8000 Identical
Inventory 704 Pcs New Original In Stock 1060 Pcs New Original In Stock Different availability
Packaging Standard Bulk Different format

Engineering Selection Recommendations

Part 644462-4 Selection Criteria:

  • Applications requiring tin-lead contact finish specification
  • Systems with RoHS non-compliant material requirements
  • Designs where legacy tin-lead specifications are mandated
  • Standard packaging requirements

Part 3-644462-4 Selection Criteria:

  • Applications subject to ROHS3 compliance requirements
  • Environmental or regulatory frameworks requiring lead-free contact materials
  • Higher inventory availability for volume production
  • Bulk packaging format for manufacturing operations

Both parts maintain identical electrical performance, mechanical dimensions, and functional compatibility within the MTA-156 series. Selection between these alternatives is determined by compliance certification requirements and packaging format needs rather than electrical or mechanical performance differences.

Frequently Asked Questions (FAQ)

Q: Can 644462-4 and 3-644462-4 be used interchangeably in the same circuit?

A: Yes. Both connectors maintain identical electrical specifications, mechanical dimensions, pitch, contact count, and termination method. The primary differences are contact finish material (tin-lead vs. tin) and RoHS compliance status. Functional interchangeability is preserved across both parts.

Q: What is the significance of the contact finish difference between tin-lead and tin?

A: The contact finish material affects compliance certifications and environmental regulations. Tin-lead (644462-4) is RoHS non-compliant, while tin (3-644462-4) is ROHS3 compliant. Both finishes maintain the same thickness specification (80.0µin / 2.03µm) and provide equivalent electrical performance for this connector application.

Q: Are the mechanical dimensions identical between these two parts?

A: Yes. Both parts share identical pitch (0.156" / 3.96mm), position count (4), mounting configuration (Free Hanging In-Line), and housing design. They are mechanically interchangeable.

Q: What does IDC termination mean for these connectors?

A: IDC (Insulation Displacement Contact) termination allows direct connection of 20 AWG discrete or ribbon cable without stripping insulation. The connector contacts pierce the cable insulation during termination, establishing electrical connection.

Q: Does packaging format affect connector performance?

A: No. Standard and bulk packaging formats contain identical connectors. Packaging differences relate only to quantity per unit and handling for manufacturing operations. Electrical and mechanical performance remains unchanged.

Q: What is the Moisture Sensitivity Level (MSL) rating?

A: Both parts carry MSL 1 (Unlimited), indicating no moisture sensitivity restrictions. These connectors can be stored and handled without special humidity control measures.

Q: Are these connectors suitable for ribbon cable applications?

A: Yes. Both connectors support discrete or ribbon cable termination via IDC method at 20 AWG wire gauge. The closed-end design with polarizing key ensures proper cable orientation during termination.

Request Quote (Ships tomorrow)