6055-024 Equivalent & Substitute Parts

Part Overview

The 6055-024 is a laminated core power transformer rated at 48VA with dual primary and secondary windings, manufactured by API Delevan Inc. This through-hole mounted component supports dual voltage configurations on both primary (115V/230V) and secondary (Parallel 12V/Series 24V) sides. The part is classified as obsolete, making identification of active equivalent models essential for ongoing design support and procurement continuity.

Substiute Parts

6055-024
API Delevan Inc.In Stock: 11886055-024 Datasheet
6055-024
Current Part
6055R-024
API Delevan Inc.In Stock: 12556055R-024 Datasheet
6055R-024
Direct

Key Parameters

Parameter Value
Manufacturer Part Number 6055-024
Manufacturer API Delevan Inc.
Series 6055
Product Status Obsolete
Type Laminated Core
Power Rating 48VA
Voltage - Primary 115V, 230V
Voltage - Secondary (Full Load) Parallel 12V, Series 24V
Current - Output (Max) Parallel 4A, Series 2A
Primary Winding(s) Dual
Secondary Winding(s) Dual
Mounting Type Through Hole
Termination Style PC Pin
Voltage - Isolation 1500Vrms
RoHS Status RoHS non-compliant

Substitute Part Grouping Explanation

Substitution of the 6055-024 is determined by strict equivalence across the following electrical and mechanical parameters:

  • Power Rating: 48VA (exact match required)
  • Primary Voltage Configuration: Dual 115V/230V (exact match required)
  • Secondary Voltage Configuration: Parallel 12V/Series 24V (exact match required)
  • Output Current Capacity: Parallel 4A/Series 2A (exact match required)
  • Winding Configuration: Dual primary and dual secondary (exact match required)
  • Core Type: Laminated (exact match required)
  • Mounting and Termination: Through Hole with PC Pin termination (exact match required)
  • Isolation Voltage: 1500Vrms (exact match required)
  • Physical Dimensions: 47.63mm L × 39.67mm W × 36.50mm H (exact match required)

The 6055R-024 meets all substitution criteria as an active equivalent model within the same manufacturer's product line.

Parameter Comparison

Parameter 6055-024 (Main Part) 6055R-024 (Substitute)
Manufacturer Part Number 6055-024 6055R-024
Manufacturer API Delevan Inc. API Delevan Inc.
Series 6055 6055R
Product Status Obsolete Active
Type Laminated Core Laminated Core
Power - Max 48VA 48VA
Voltage - Primary 115V, 230V 115V, 230V
Voltage - Secondary (Full Load) Parallel 12V, Series 24V Parallel 12V, Series 24V
Current - Output (Max) Parallel 4A, Series 2A Parallel 4A, Series 2A
Primary Winding(s) Dual Dual
Secondary Winding(s) Dual Dual
Mounting Type Through Hole Through Hole
Termination Style PC Pin PC Pin
Size / Dimension 47.63mm L x 39.67mm W 47.63mm L x 39.67mm W
Height - Seated (Max) 36.50mm 36.50mm
Voltage - Isolation 1500Vrms 1500Vrms
Weight 1.4 lbs (635 g) 1.4 lbs (635 g)
RoHS Status RoHS non-compliant ROHS3 Compliant

Engineering Selection Recommendations

The 6055R-024 is the direct active equivalent for the obsolete 6055-024. Both components share identical electrical specifications, power ratings, voltage configurations, winding arrangements, and physical dimensions. The primary distinction is product status: the 6055-024 is obsolete while the 6055R-024 is active in production.

An additional consideration is regulatory compliance. The 6055R-024 is ROHS3 compliant, whereas the 6055-024 is RoHS non-compliant. For applications subject to RoHS directives or environmental regulations, the 6055R-024 provides compliance alignment. Both components maintain REACH Unaffected status and EAR99 export classification.

Selection of the 6055R-024 is appropriate for new designs, redesigns, or replacement of obsolete inventory where regulatory compliance is required or preferred.

Frequently Asked Questions (FAQ)

Q: Can the 6055R-024 be used as a direct replacement for the 6055-024 in existing designs?

A: Yes. The 6055R-024 is electrically and mechanically equivalent to the 6055-024. All electrical parameters, winding configurations, voltage ratings, current capacities, isolation voltage, and physical dimensions are identical. Through-hole mounting and PC pin termination are unchanged.

Q: What is the difference between the 6055-024 and 6055R-024?

A: The primary differences are product status and RoHS compliance. The 6055-024 is obsolete and RoHS non-compliant. The 6055R-024 is active in production and ROHS3 compliant. All electrical and mechanical specifications are identical.

Q: Are there any compatibility concerns when substituting the 6055R-024 for the 6055-024?

A: No compatibility concerns exist. Identical dimensions, mounting type, termination style, and electrical characteristics ensure direct compatibility in PCB layouts and circuit designs.

Q: Does the RoHS3 compliance of the 6055R-024 affect its electrical performance compared to the 6055-024?

A: No. RoHS compliance relates to material composition and environmental standards, not electrical performance. Both transformers deliver identical electrical specifications and performance characteristics.

Q: What inventory status should be considered when selecting between these parts?

A: The 6055-024 has 1139 pieces in stock but is obsolete. The 6055R-024 has 1169 pieces in stock and is active. For long-term availability and design continuity, the 6055R-024 is the preferred selection.

Request Quote (Ships tomorrow)