API Delevan 6051-016 Equivalent & Substitute Parts

Part Overview

The API Delevan 6051-016 is a laminated core power transformer rated at 2.5VA with dual primary and secondary windings. This transformer supports dual voltage inputs (115V or 230V) and provides parallel (8V at 312mA) or series (16V at 156mA) output configurations. The part is classified as obsolete, making the identification of active equivalent components essential for ongoing maintenance and new design implementation.

Substiute Parts

6051-016
API Delevan Inc.In Stock: 10146051-016 Datasheet
6051-016
Current Part
6051R-016
API Delevan Inc.In Stock: 10836051R-016 Datasheet
6051R-016
Direct

Key Parameters

Parameter Value
Power Rating 2.5VA
Primary Voltage Options 115V, 230V
Secondary Voltage - Parallel 8V
Secondary Voltage - Series 16V
Output Current - Parallel 312mA
Output Current - Series 156mA
Winding Configuration Dual Primary, Dual Secondary
Core Type Laminated
Isolation Voltage 1500Vrms
Mounting Type Through Hole
Termination Style PC Pin
Physical Dimensions 47.60mm L x 39.60mm W
Height - Seated (Max) 16.50mm
Weight 0.313 lb (141.97 g)

Substitute Part Grouping Explanation

The API Delevan 6051R-016 qualifies as a direct substitute for the 6051-016 based on the following critical parameters:

Matching Electrical Parameters:

  • Power rating: 2.5VA (identical)
  • Primary voltage inputs: 115V, 230V (identical)
  • Secondary voltage outputs: Parallel 8V / Series 16V (identical)
  • Maximum output current: Parallel 312mA / Series 156mA (identical)
  • Winding configuration: Dual primary, dual secondary (identical)
  • Isolation voltage: 1500Vrms (identical)

Matching Mechanical Parameters:

  • Core type: Laminated (identical)
  • Mounting type: Through Hole (identical)
  • Termination style: PC Pin (identical)
  • Physical dimensions: 47.60mm L x 39.60mm W (identical)
  • Height: 16.50mm maximum (identical)
  • Weight: 0.313 lb (141.97 g) (identical)

The 6051R-016 is the active production successor to the obsolete 6051-016, maintaining full electrical and mechanical compatibility while offering improved regulatory compliance.

Parameter Comparison

Parameter 6051-016 (Main Part) 6051R-016 (Substitute)
Manufacturer API Delevan Inc. API Delevan Inc.
Product Status Obsolete Active
Power Rating 2.5VA 2.5VA
Primary Voltage 115V, 230V 115V, 230V
Secondary Voltage (Parallel/Series) 8V / 16V 8V / 16V
Output Current (Parallel/Series) 312mA / 156mA 312mA / 156mA
Winding Configuration Dual Primary, Dual Secondary Dual Primary, Dual Secondary
Core Type Laminated Laminated
Isolation Voltage 1500Vrms 1500Vrms
Mounting Type Through Hole Through Hole
Termination Style PC Pin PC Pin
Dimensions (L x W) 47.60mm x 39.60mm 47.60mm x 39.60mm
Height - Seated (Max) 16.50mm 16.50mm
Weight 0.313 lb (141.97 g) 0.313 lb (141.97 g)
RoHS Status Non-compliant ROHS3 Compliant
REACH Status Unaffected Unaffected

Engineering Selection Recommendations

The 6051R-016 is the recommended substitute for the obsolete 6051-016. Both components share identical electrical performance and mechanical footprints, ensuring direct compatibility in existing designs. The primary distinction between these components is regulatory compliance: the 6051-016 is non-compliant with RoHS3 standards, while the 6051R-016 meets ROHS3 compliance requirements.

For applications subject to RoHS3 regulatory requirements, the 6051R-016 is the appropriate selection. For legacy systems where regulatory compliance is not a constraint, either component provides equivalent functionality. The active production status of the 6051R-016 ensures continued availability and supply chain stability.

Frequently Asked Questions (FAQ)

Q: Can the 6051R-016 directly replace the 6051-016 in existing designs?

A: Yes. The 6051R-016 maintains identical electrical specifications (2.5VA power rating, dual 115V/230V primary inputs, 8V/16V secondary outputs, 312mA/156mA maximum currents) and mechanical characteristics (Through Hole mounting, PC Pin termination, 47.60mm x 39.60mm footprint, 16.50mm height). No circuit modifications or PCB layout changes are required.

Q: What is the primary difference between the 6051-016 and 6051R-016?

A: The 6051R-016 is the active production equivalent of the obsolete 6051-016. The components are electrically and mechanically identical. The 6051R-016 provides ROHS3 compliance, whereas the 6051-016 is RoHS non-compliant. Both maintain REACH Unaffected status and EAR99 ECCN classification.

Q: Are both parts available for procurement?

A: The 6051-016 is obsolete and subject to stock availability limitations. The 6051R-016 is in active production with higher inventory levels, ensuring reliability for current and future procurement.

Q: What are the output current limitations for each voltage configuration?

A: The transformer supports two secondary winding configurations. In parallel configuration, the secondary provides 8V at maximum 312mA. In series configuration, the secondary provides 16V at maximum 156mA. Both the 6051-016 and 6051R-016 support these identical output parameters.

Q: Does the center-tap configuration differ between parts?

A: No. Neither the 6051-016 nor the 6051R-016 includes a center-tap winding. Both utilize dual primary and dual secondary winding configurations without center-tap provisions.


This reference page is ready for direct inclusion in web Markdown editors and follows all specified formatting requirements.

Request Quote (Ships tomorrow)