6025-024 Equivalent & Substitute Parts

Part Overview

The 6025-024 is a laminated core power transformer manufactured by API Delevan Inc., rated for 12VA with dual primary and secondary windings. This through-hole mounted component supports both 115V and 230V primary inputs with configurable secondary outputs of 12V (parallel) or 24V (series). The part is classified as obsolete, necessitating identification of active equivalent models to maintain design continuity and ensure supply chain availability for new production and field replacements.

Substiute Parts

6025-024
API Delevan Inc.In Stock: 12056025-024 Datasheet
6025-024
Current Part
6025R-024
API Delevan Inc.In Stock: 9946025R-024 Datasheet
6025R-024
Direct

Key Parameters

Parameter Specification
Manufacturer Part Number 6025-024
Manufacturer API Delevan Inc.
Series 6025
Type Laminated Core
Power Rating 12VA
Voltage - Primary 115V, 230V
Voltage - Secondary (Full Load) Parallel 12V, Series 24V
Current - Output (Max) Parallel 1A, Series 500mA
Primary Winding(s) Dual
Secondary Winding(s) Dual
Center Tap No
Mounting Type Through Hole
Termination Style PC Pin
Size / Dimension 47.63mm L x 39.67mm W
Height - Seated (Max) 36.50mm
Voltage - Isolation 2500Vrms
Weight 0.7 lb (317.51 g)
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the 6025-024 is determined by strict equivalence across the following critical parameters:

  • Core Type: Laminated core construction
  • Power Rating: 12VA maximum
  • Primary Voltage Configuration: Dual primary windings supporting 115V and 230V inputs
  • Secondary Voltage Configuration: Dual secondary windings with parallel 12V / series 24V output capability
  • Output Current Ratings: Parallel 1A maximum, series 500mA maximum
  • Mounting and Termination: Through-hole mounting with PC pin termination
  • Physical Dimensions: 47.63mm L x 39.67mm W footprint with 36.50mm maximum seated height
  • Isolation Voltage: 2500Vrms minimum

The 6025R-024 meets all specified electrical and mechanical parameters, providing functional equivalence while offering improved regulatory compliance status.

Parameter Comparison

Parameter 6025-024 (Obsolete) 6025R-024 (Active)
Manufacturer Part Number 6025-024 6025R-024
Series 6025 6025R
Product Status Obsolete Active
Type Laminated Core Laminated Core
Power - Max 12VA 12VA
Voltage - Primary 115V, 230V 115V, 230V
Voltage - Secondary (Full Load) Parallel 12V, Series 24V Parallel 12V, Series 24V
Current - Output (Max) Parallel 1A, Series 500mA Parallel 1A, Series 500mA
Primary Winding(s) Dual Dual
Secondary Winding(s) Dual Dual
Center Tap No No
Mounting Type Through Hole Through Hole
Termination Style PC Pin PC Pin
Size / Dimension 47.63mm L x 39.67mm W 47.63mm L x 39.67mm W
Height - Seated (Max) 36.50mm 36.50mm
Voltage - Isolation 2500Vrms 2500Vrms
Weight 0.7 lb (317.51 g) 0.7 lb (317.51 g)
RoHS Status RoHS non-compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.31.4035 8504.31.4035

Engineering Selection Recommendations

The 6025R-024 is the direct active equivalent for the obsolete 6025-024. Both components are electrically and mechanically identical across all specified parameters. The primary distinction is regulatory compliance: the 6025R-024 achieves ROHS3 compliance, whereas the 6025-024 is non-compliant. For new designs and production applications, the 6025R-024 is the appropriate selection. For legacy systems currently using the 6025-024, the 6025R-024 provides drop-in replacement capability with enhanced environmental compliance.

Frequently Asked Questions (FAQ)

Q: Can the 6025R-024 directly replace the 6025-024 in existing designs?

A: Yes. The 6025R-024 is electrically and mechanically equivalent to the 6025-024. Both components share identical power ratings, voltage configurations, winding specifications, mounting type, termination style, and physical dimensions. Direct substitution is supported without circuit modification.

Q: What is the primary difference between these two parts?

A: The 6025R-024 is the active production equivalent with ROHS3 compliance, while the 6025-024 is classified as obsolete and does not meet RoHS requirements. The 6025R-024 is recommended for all new applications.

Q: Are the physical dimensions identical?

A: Yes. Both the 6025-024 and 6025R-024 maintain identical footprints of 47.63mm L x 39.67mm W with a maximum seated height of 36.50mm, ensuring PCB layout compatibility.

Q: Do both parts support the same voltage configurations?

A: Yes. Both components feature dual primary windings supporting 115V and 230V inputs, and dual secondary windings providing parallel 12V (1A max) or series 24V (500mA max) output configurations.

Q: What is the isolation voltage rating?

A: Both the 6025-024 and 6025R-024 are rated for 2500Vrms isolation voltage.

Q: Are there any compliance differences I should consider?

A: The 6025R-024 is ROHS3 compliant, making it suitable for applications subject to RoHS regulations. The 6025-024 is non-compliant. Both share identical REACH and ECCN classifications.

Request Quote (Ships tomorrow)