Request Quote
(Ships tomorrow)
API Delevan 6025-016 Equivalent & Substitute Parts
Part Overview
The API Delevan 6025-016 is a laminated core power transformer with 12VA maximum power rating, dual primary and secondary windings, and through-hole mounting. This transformer is classified as obsolete, necessitating the identification of active substitute models that maintain equivalent electrical and mechanical specifications. The 6025R-016 series provides a direct functional replacement with current manufacturing status and improved compliance characteristics.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Power Rating (Max) | 12VA |
| Voltage - Primary | 115V, 230V |
| Voltage - Secondary (Parallel) | 8V |
| Voltage - Secondary (Series) | 16V |
| Current - Output (Parallel) | 1.6A |
| Current - Output (Series) | 800mA |
| Core Type | Laminated |
| Primary Windings | Dual |
| Secondary Windings | Dual |
| Voltage Isolation | 2500Vrms |
| Mounting Type | Through Hole |
| Termination Style | PC Pin |
| Physical Dimensions | 47.63mm L x 39.67mm W x 36.50mm H |
Substitute Part Grouping Explanation
Substitute parts are qualified when they maintain identical electrical performance parameters and mechanical compatibility. For the 6025-016, substitution logic is based on the following critical parameters:
- Power Rating: 12VA maximum (fixed)
- Dual Voltage Primary: 115V/230V configuration (fixed)
- Dual Voltage Secondary: Parallel 8V/1.6A and Series 16V/800mA outputs (fixed)
- Core Construction: Laminated core technology (fixed)
- Winding Configuration: Dual primary and dual secondary windings (fixed)
- Isolation Rating: 2500Vrms (fixed)
- Form Factor: Through-hole mounting with PC pin termination (fixed)
- Physical Envelope: 47.63mm x 39.67mm x 36.50mm maximum dimensions (fixed)
Any variation in these parameters disqualifies a part as a direct substitute.
Parameter Comparison
| Parameter | 6025-016 (Main) | 6025R-016 (Substitute) |
|---|---|---|
| Manufacturer | API Delevan Inc. | API Delevan Inc. |
| Series Designation | 6025 | 6025R |
| Power Rating (Max) | 12VA | 12VA |
| Voltage - Primary | 115V, 230V | 115V, 230V |
| Voltage - Secondary (Parallel) | 8V | 8V |
| Voltage - Secondary (Series) | 16V | 16V |
| Current - Output (Parallel) | 1.6A | 1.6A |
| Current - Output (Series) | 800mA | 800mA |
| Core Type | Laminated | Laminated |
| Primary Windings | Dual | Dual |
| Secondary Windings | Dual | Dual |
| Voltage Isolation | 2500Vrms | 2500Vrms |
| Mounting Type | Through Hole | Through Hole |
| Termination Style | PC Pin | PC Pin |
| Physical Dimensions | 47.63mm L x 39.67mm W x 36.50mm H | 47.63mm L x 39.67mm W x 36.50mm H |
| Weight | 0.7 lb (317.51 g) | 0.7 lb (317.51 g) |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
The 6025R-016 qualifies as a direct functional substitute for the obsolete 6025-016. Both parts share identical electrical specifications and physical form factors, enabling mechanical and electrical compatibility in existing designs without circuit modification. The 6025R-016 carries active manufacturing status through API Delevan Inc., ensuring long-term availability. The 6025R-016 additionally achieves ROHS3 compliance, providing enhanced environmental qualification over the non-compliant 6025-016. Both parts maintain REACH Unaffected status. Selection between these parts is determined by procurement availability and regulatory compliance requirements applicable to the end application.
Frequently Asked Questions (FAQ)
Q: Can the 6025R-016 replace the 6025-016 in existing circuit designs?
A: Yes. The 6025R-016 maintains identical electrical performance specifications, primary and secondary voltage ratings, current output capabilities, isolation voltage, and physical dimensions as the 6025-016. Direct substitution requires no circuit design changes or PCB layout modifications.
Q: What is the primary difference between these two parts?
A: The 6025-016 is classified as obsolete with RoHS non-compliance status. The 6025R-016 is manufactured to ROHS3 standards with active manufacturing status. All electrical and mechanical parameters remain equivalent.
Q: Are the through-hole mounting patterns and PC pin configurations identical?
A: Yes. Both parts utilize identical through-hole mounting type and PC pin termination style, with matching physical envelope dimensions of 47.63mm length, 39.67mm width, and 36.50mm seated height. Direct footprint compatibility is maintained.
Q: Does the dual secondary winding configuration operate identically in both parts?
A: Yes. Both transformers provide dual secondary windings with 8V/1.6A output in parallel configuration and 16V/800mA output in series configuration. Winding isolation voltage is 2500Vrms for both parts.
Q: What inventory availability exists for these parts?
A: The 6025-016 has 838 pieces available as new original stock. The 6025R-016 has 715 pieces available as new original stock. Availability status may change; current inventory should be confirmed through the distributor at time of order.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts