6014-120 Equivalent & Substitute Parts

Part Overview

The 6014-120 is a laminated core power transformer rated at 6VA with dual secondary windings, manufactured by API Delevan Inc. This through-hole mounted component features a single 115V primary winding with parallel/series configurable secondary outputs of 60V/120V. The part is classified as obsolete, making identification of functionally equivalent alternatives essential for ongoing system support and new design implementations.

Substiute Parts

6014-120
API Delevan Inc.In Stock: 8376014-120 Datasheet
6014-120
Current Part
6014R-120
API Delevan Inc.In Stock: 8676014R-120 Datasheet
6014R-120
Direct

Key Parameters

Parameter Value
Manufacturer Part Number 6014-120
Manufacturer API Delevan Inc.
Series 6014
Power Rating 6VA
Primary Voltage 115V
Secondary Voltage (Parallel/Series) 60V / 120V
Secondary Current (Parallel/Series) 100mA / 50mA
Core Type Laminated
Mounting Type Through Hole
Termination Style PC Pin
Isolation Voltage 2500Vrms
Dimensions 41.28mm L × 33.32mm W × 33.32mm H
Weight 0.44 lb (199.58 g)
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the 6014-120 is determined by strict equivalence across the following critical parameters:

  • Power Rating: 6VA maximum
  • Primary Voltage: 115V single winding
  • Secondary Configuration: Dual windings with parallel 60V/100mA and series 120V/50mA capability
  • Core Type: Laminated construction
  • Mounting and Termination: Through-hole PC pin configuration
  • Isolation Voltage: 2500Vrms minimum
  • Physical Envelope: 41.28mm L × 33.32mm W × 33.32mm H

The 6014R-120 meets all electrical and mechanical parameters required for direct substitution. Differences in product status and compliance certifications do not affect functional equivalence.

Parameter Comparison

Parameter 6014-120 (Main Part) 6014R-120 (Substitute) Equivalence
Manufacturer API Delevan Inc. API Delevan Inc. Identical
Power Rating 6VA 6VA Identical
Primary Voltage 115V 115V Identical
Secondary Voltage (Parallel) 60V 60V Identical
Secondary Voltage (Series) 120V 120V Identical
Secondary Current (Parallel) 100mA 100mA Identical
Secondary Current (Series) 50mA 50mA Identical
Core Type Laminated Laminated Identical
Primary Windings Single Single Identical
Secondary Windings Dual Dual Identical
Mounting Type Through Hole Through Hole Identical
Termination Style PC Pin PC Pin Identical
Isolation Voltage 2500Vrms 2500Vrms Identical
Dimensions 41.28mm L × 33.32mm W × 33.32mm H 41.28mm L × 33.32mm W × 33.32mm H Identical
Weight 0.44 lb (199.58 g) 0.44 lb (199.58 g) Identical
Product Status Obsolete Active Different
RoHS Status RoHS non-compliant ROHS3 Compliant Different

Engineering Selection Recommendations

The 6014R-120 is a direct functional equivalent to the 6014-120 across all electrical and mechanical specifications. The primary distinction is product lifecycle status: the 6014-120 is obsolete while the 6014R-120 is active production.

For new designs and ongoing system support, the 6014R-120 is the appropriate selection. This part maintains identical electrical performance, physical form factor, and mounting characteristics while offering the advantage of active manufacturer support and ROHS3 compliance certification.

For legacy systems currently using the 6014-120, the 6014R-120 provides drop-in compatibility without circuit redesign or PCB modification.

Frequently Asked Questions (FAQ)

Q: Can the 6014R-120 replace the 6014-120 in existing applications?

A: Yes. The 6014R-120 is electrically and mechanically identical to the 6014-120. All voltage ratings, current capabilities, isolation specifications, and physical dimensions match exactly. No circuit modifications or PCB changes are required.

Q: What is the difference between the 6014-120 and 6014R-120?

A: The parts are functionally equivalent. The 6014R-120 is the active production variant with ROHS3 compliance certification, while the 6014-120 is classified as obsolete. The "R" designation in the 6014R series indicates the updated compliance status.

Q: Are the secondary winding configurations identical?

A: Yes. Both parts feature dual secondary windings with identical parallel (60V/100mA) and series (120V/50mA) configurations. Winding polarity and connection points are equivalent.

Q: Do the parts have the same physical footprint?

A: Yes. Both transformers share identical dimensions of 41.28mm length × 33.32mm width × 33.32mm height with through-hole PC pin termination. No PCB layout changes are necessary for substitution.

Q: What is the isolation voltage rating?

A: Both the 6014-120 and 6014R-120 are rated for 2500Vrms isolation between primary and secondary windings.

Request Quote (Ships tomorrow)