6014-048 Laminated Power Transformer 6VA

Part Overview

The 6014-048 is a laminated core power transformer rated at 6VA with a single primary winding (115V) and dual secondary windings (24V parallel or 48V series). The part is currently obsolete and has been superseded by the 6014R-048 variant. The transition to an active product status and improved compliance characteristics necessitates identifying suitable alternatives for new designs and ongoing applications.

Substiute Parts

6014-048
API Delevan Inc.In Stock: 11506014-048 Datasheet
6014-048
Current Part
6014R-048
API Delevan Inc.In Stock: 9546014R-048 Datasheet
6014R-048
Direct

Key Parameters

Parameter Value
Voltage - Primary 115V
Voltage - Secondary (Full Load) Parallel 24V, Series 48V
Power - Max 6VA
Current - Output (Max) Parallel 250mA, Series 125mA
Primary Winding(s) Single
Secondary Winding(s) Dual
Type Laminated Core
Mounting Type Through Hole
Termination Style PC Pin
Voltage - Isolation 2500Vrms
Size / Dimension 41.28mm L x 33.32mm W
Height - Seated (Max) 33.32mm
Weight 0.44 lb (199.58 g)

Substitute Part Grouping Explanation

Substitution of the 6014-048 is determined by electrical and mechanical parameter matching. The primary criteria are:

  • Voltage specifications: Primary voltage of 115V and dual secondary configuration with 24V parallel or 48V series output
  • Power rating: 6VA maximum power capacity
  • Output current capabilities: 250mA in parallel configuration, 125mA in series configuration
  • Physical compatibility: Through-hole mounting with PC pin termination, matching footprint dimensions (41.28mm L x 33.32mm W)
  • Electrical isolation: 2500Vrms isolation voltage requirement
  • Core type: Laminated core construction

The 6014R-048 meets all these electrical and mechanical specifications identically while providing improved product status and enhanced compliance characteristics.

Parameter Comparison

Parameter 6014-048 6014R-048
Manufacturer API Delevan Inc. API Delevan Inc.
Series 6014 6014R
Product Status Obsolete Active
Type Laminated Core Laminated Core
Voltage - Primary 115V 115V
Voltage - Secondary (Full Load) Parallel 24V, Series 48V Parallel 24V, Series 48V
Current - Output (Max) Parallel 250mA, Series 125mA Parallel 250mA, Series 125mA
Primary Winding(s) Single Single
Secondary Winding(s) Dual Dual
Center Tap No No
Power - Max 6VA 6VA
Mounting Type Through Hole Through Hole
Termination Style PC Pin PC Pin
Size / Dimension 41.28mm L x 33.32mm W 41.28mm L x 33.32mm W
Height - Seated (Max) 33.32mm 33.32mm
Voltage - Isolation 2500Vrms 2500Vrms
Weight 0.44 lb (199.58 g) 0.44 lb (199.58 g)
RoHS Status RoHS non-compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.31.4035 8504.31.4035

Engineering Selection Recommendations

The 6014R-048 is the direct equivalent for the obsolete 6014-048 model. Both parts provide identical electrical specifications and mechanical form factors. The primary distinction is that the 6014R-048 carries active product status with ROHS3 compliance, whereas the original 6014-048 is obsolete and RoHS non-compliant. For new designs or applications requiring regulatory compliance, the 6014R-048 is the appropriate selection. The 6014R-048 supports direct mechanical and electrical substitution without design modifications.

Frequently Asked Questions (FAQ)

Q: Can the 6014R-048 be used as a direct replacement for the 6014-048? A: Yes. The 6014R-048 provides identical electrical performance, output current capability, isolation voltage, and physical dimensions as the 6014-048.

Q: What is the difference between the 6014-048 and 6014R-048 part numbers? A: The primary differences are product status and regulatory compliance. The 6014-048 is obsolete and RoHS non-compliant. The 6014R-048 is an active product with ROHS3 compliance.

Q: Are the mounting footprints identical? A: Yes. Both transformers use through-hole mounting with PC pin termination and are dimensionally identical at 41.28mm L x 33.32mm W with a maximum seated height of 33.32mm.

Q: Will the 6014R-048 work in parallel and series winding configurations? A: Yes. The dual secondary winding configuration supports both 24V parallel output (250mA maximum) and 48V series output (125mA maximum) operation.

Q: Do these transformers meet isolation requirements for safety-critical applications? A: Both the 6014-048 and 6014R-048 provide 2500Vrms isolation voltage. Confirmation of suitability for specific safety applications requires review of applicable design standards and certifications.