Request Quote
(Ships tomorrow)
6014-024 Equivalent & Substitute Parts
Part Overview
The 6014-024 is a laminated core power transformer manufactured by API Delevan Inc., rated at 6VA with a primary voltage of 115V and dual secondary windings configured for either parallel 12V or series 24V output. This through-hole mounted component features PC pin termination and is designed for traditional power supply applications requiring galvanic isolation.
The 6014-024 carries an obsolete product status, making it necessary to identify equivalent or substitute components for ongoing system support and new designs. The part is RoHS non-compliant and carries REACH Unaffected classification.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 6014-024 |
| Manufacturer | API Delevan Inc. |
| Series | 6014 |
| Type | Laminated Core |
| Power Rating | 6VA |
| Primary Voltage | 115V |
| Secondary Voltage (Parallel) | 12V |
| Secondary Voltage (Series) | 24V |
| Output Current - Parallel | 500mA |
| Output Current - Series | 250mA |
| Primary Winding(s) | Single |
| Secondary Winding(s) | Dual |
| Center Tap | No |
| Mounting Type | Through Hole |
| Termination Style | PC Pin |
| Isolation Voltage | 2500Vrms |
| Dimensions (L x W) | 41.28mm x 33.32mm |
| Height - Seated (Max) | 33.32mm |
| Weight | 0.44 lb (199.58 g) |
| Product Status | Obsolete |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Unaffected |
Substitute Part Grouping Explanation
No direct substitute parts are currently available in the provided database. Equivalent components must satisfy the following critical parameters to function as substitutes for the 6014-024:
- Power rating of 6VA
- Primary voltage of 115V
- Dual secondary windings with 12V parallel and 24V series configuration capability
- Output current capacity of 500mA (parallel) and 250mA (series)
- Through-hole mounting with PC pin termination
- Laminated core construction
- Isolation voltage of 2500Vrms or greater
Substitution candidates must maintain identical electrical specifications and mechanical compatibility to ensure proper operation within existing circuit designs and PCB layouts.
Parameter Comparison
No substitute parts are available for comparison at this time.
Engineering Selection Recommendations
The 6014-024 is classified as obsolete. When sourcing replacement components, prioritize parts that maintain exact electrical and mechanical specifications. Verify that any candidate substitute meets the 2500Vrms isolation requirement and supports the dual secondary winding configuration with parallel and series output modes.
For applications requiring RoHS compliance, identify substitutes that meet RoHS standards while maintaining all other electrical and mechanical parameters. Confirm through-hole mounting compatibility and PC pin termination to ensure direct PCB integration without redesign.
Frequently Asked Questions (FAQ)
Q: What makes a transformer suitable as a substitute for the 6014-024?
A: A substitute must provide 6VA power rating, 115V primary input, dual secondary windings supporting both 12V parallel and 24V series configurations, 500mA parallel and 250mA series output current, through-hole mounting, PC pin termination, and 2500Vrms isolation voltage.
Q: Can I use a transformer with different secondary voltage ratings?
A: No. The 6014-024 requires specific dual secondary winding configuration with 12V parallel and 24V series output. Substitutes must provide identical voltage ratings to maintain circuit functionality.
Q: Does mounting type affect substitution compatibility?
A: Yes. The 6014-024 uses through-hole mounting with PC pin termination. Substitutes must use identical mounting and termination styles to ensure PCB compatibility without layout modifications.
Q: Is RoHS compliance required for substitution?
A: The 6014-024 is RoHS non-compliant. If your application requires RoHS compliance, identify substitutes that meet RoHS standards while maintaining all electrical and mechanical specifications.
Q: What is the significance of the 2500Vrms isolation voltage?
A: Isolation voltage specifies the maximum voltage that can be safely applied between primary and secondary windings. Substitutes must meet or exceed 2500Vrms to maintain safety and performance specifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts