Part Overview

The API Delevan Inc. 6014-010 is a laminated core power transformer rated for 6VA maximum power with a 115V primary voltage and dual secondary windings (5V parallel, 10V series). This through-hole mounted transformer features PC pin termination and 2500Vrms isolation voltage. The 6014-010 is currently obsolete with 1172 units available in inventory. Due to its obsolete status, the 6014R-010 provides a direct active production equivalent maintaining full electrical and mechanical compatibility.

Substiute Parts

6014-010
API Delevan Inc.In Stock: 12786014-010 Datasheet
6014-010
Current Part
6014R-010
API Delevan Inc.In Stock: 10006014R-010 Datasheet
6014R-010
Direct

Key Parameters

Parameter Specification
Manufacturer Part Number 6014-010
Manufacturer API Delevan Inc.
Series 6014
Type Laminated Core
Power - Max 6VA
Voltage - Primary 115V
Voltage - Secondary (Full Load) Parallel 5V, Series 10V
Current - Output (Max) Parallel 1.2A, Series 600mA
Primary Winding(s) Single
Secondary Winding(s) Dual
Voltage - Isolation 2500Vrms
Mounting Type Through Hole
Termination Style PC Pin
Size / Dimension 41.28mm L x 33.32mm W
Height - Seated (Max) 33.32mm
Weight 0.44 lb (199.58 g)

Substitute Part Grouping Explanation

The 6014R-010 qualifies as a direct substitute for the 6014-010 based on matching electrical and mechanical parameters. Substitution eligibility is determined by the following critical parameters:

  • Primary voltage: 115V (identical)
  • Secondary voltage configuration: Parallel 5V, Series 10V (identical)
  • Maximum output current: Parallel 1.2A, Series 600mA (identical)
  • Power rating: 6VA (identical)
  • Core type: Laminated (identical)
  • Isolation voltage: 2500Vrms (identical)
  • Mounting type: Through Hole (identical)
  • Termination style: PC Pin (identical)
  • Physical dimensions: 41.28mm L x 33.32mm W x 33.32mm H (identical)

The 6014R-010 represents the active production variant of the 6014 series, maintaining 100% electrical and mechanical compatibility while offering improved regulatory compliance.

Parameter Comparison

Parameter 6014-010 (Main Part) 6014R-010 (Substitute)
Manufacturer Part Number 6014-010 6014R-010
Series 6014 6014R
Product Status Obsolete Active
Type Laminated Core Laminated Core
Voltage - Primary 115V 115V
Voltage - Secondary (Full Load) Parallel 5V, Series 10V Parallel 5V, Series 10V
Current - Output (Max) Parallel 1.2A, Series 600mA Parallel 1.2A, Series 600mA
Primary Winding(s) Single Single
Secondary Winding(s) Dual Dual
Voltage - Isolation 2500Vrms 2500Vrms
Power - Max 6VA 6VA
Mounting Type Through Hole Through Hole
Termination Style PC Pin PC Pin
Size / Dimension 41.28mm L x 33.32mm W 41.28mm L x 33.32mm W
Height - Seated (Max) 33.32mm 33.32mm
Weight 0.44 lb (199.58 g) 0.44 lb (199.58 g)
RoHS Status RoHS non-compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.31.4035 8504.31.4035
Inventory Status 1172 Pcs New Original In Stock 969 Pcs New Original In Stock

Engineering Selection Recommendations

For new designs and production applications, the 6014R-010 is the recommended selection due to its active product status and ROHS3 compliance. The 6014-010 remains available for legacy system maintenance and repair applications where existing inventory supports component sourcing.

The 6014R-010 provides regulatory advantage through ROHS3 certification, aligning with current environmental and manufacturing standards. Both parts maintain identical electrical performance and physical compatibility, enabling direct substitution in existing board layouts and circuit designs without redesign requirements.

The choice between these parts should be based on product lifecycle stage: the 6014R-010 for current and future development, and the 6014-010 for obsolescence management and legacy system support.

Frequently Asked Questions (FAQ)

Can the 6014R-010 replace the 6014-010 in existing designs? Yes. The 6014R-010 maintains 100% electrical and mechanical compatibility with the 6014-010. All primary voltage, secondary voltage outputs, current ratings, winding configurations, isolation voltage, mounting, termination, and physical dimensions are identical.

What is the primary difference between the 6014-010 and 6014R-010? The primary difference is product status and regulatory compliance. The 6014-010 is obsolete and RoHS non-compliant, while the 6014R-010 is an active production part certified to ROHS3 standards. Both parts are electrically and mechanically identical 6VA laminated core transformers.

Are the physical footprints identical between these parts? Yes. Both transformers have identical dimensions of 41.28mm length, 33.32mm width, and 33.32mm maximum seated height. They use identical through-hole PC pin termination, enabling direct PCB layout compatibility without modification.

Which part should be selected for new production designs? The 6014R-010 is the appropriate selection for new designs and current production due to its active status and ROHS3 compliance. The 6014-010 should only be considered for legacy system maintenance where existing inventory availability is a factor.

Are secondary voltage configurations the same on both parts? Yes. Both the 6014-010 and 6014R-010 feature dual secondary windings configured identically: 5V at 1.2A maximum in parallel connection, and 10V at 600mA maximum in series connection.

Request Quote (Ships tomorrow)