API Delevan 6013-028 Laminated Power Transformer Equivalent & Substitute Parts

Part Overview

The API Delevan 6013-028 is a laminated core power transformer rated at 2.4VA with dual secondary windings configured for parallel (14V, 170mA) or series (28V, 85mA) operation. The primary winding accepts 115V single-phase input. This through-hole mounted transformer features PC pin termination and 2500Vrms isolation voltage.

The 6013-028 carries an obsolete product status. Locating equivalent substitute parts is necessary to support ongoing maintenance, repair, and new design requirements where this transformer specification remains applicable.

Substiute Parts

6013-028
API Delevan Inc.In Stock: 9526013-028 Datasheet
6013-028
Current Part
6013R-028
API Delevan Inc.In Stock: 7746013R-028 Datasheet
6013R-028
Direct

Key Parameters

Parameter Value
Manufacturer API Delevan Inc.
Series 6013
Power Rating 2.4VA
Primary Voltage 115V
Secondary Voltage (Parallel/Series) 14V / 28V
Secondary Current (Parallel/Series) 170mA / 85mA
Core Type Laminated
Mounting Type Through Hole
Termination Style PC Pin
Isolation Voltage 2500Vrms
Physical Dimensions 34.93mm L × 28.58mm W × 30.15mm H

Substitute Part Grouping Explanation

Substitute parts for the 6013-028 are identified based on strict electrical and mechanical parameter matching. The following criteria determine substitution eligibility:

Electrical Parameters (Must Match Exactly):

  • Primary voltage: 115V
  • Secondary voltage configuration: Parallel 14V and Series 28V
  • Secondary current capacity: Parallel 170mA and Series 85mA
  • Power rating: 2.4VA
  • Isolation voltage: 2500Vrms
  • Winding configuration: Single primary, dual secondary, no center tap

Mechanical Parameters (Must Match Exactly):

  • Core type: Laminated
  • Mounting type: Through Hole
  • Termination style: PC Pin
  • Physical dimensions: 34.93mm L × 28.58mm W
  • Height seated: 30.15mm maximum

The 6013R-028 meets all electrical and mechanical substitution criteria and is classified as a direct manufacturer equivalent.

Parameter Comparison

Parameter 6013-028 (Original) 6013R-028 (Substitute) Match Status
Manufacturer API Delevan Inc. API Delevan Inc. Identical
Product Status Obsolete Active Substitute is current production
Power Rating 2.4VA 2.4VA Identical
Primary Voltage 115V 115V Identical
Secondary Voltage (Parallel) 14V 14V Identical
Secondary Voltage (Series) 28V 28V Identical
Secondary Current (Parallel) 170mA 170mA Identical
Secondary Current (Series) 85mA 85mA Identical
Core Type Laminated Laminated Identical
Mounting Type Through Hole Through Hole Identical
Termination Style PC Pin PC Pin Identical
Isolation Voltage 2500Vrms 2500Vrms Identical
Dimensions (L × W) 34.93mm × 28.58mm 34.93mm × 28.58mm Identical
Height Seated (Max) 30.15mm 30.15mm Identical
Weight 0.25 lb (113.4 g) 0.25 lb (113.4 g) Identical
RoHS Status RoHS non-compliant ROHS3 Compliant Substitute offers improved compliance
REACH Status REACH Unaffected REACH Unaffected Identical

Engineering Selection Recommendations

The 6013R-028 is the direct substitute for the obsolete 6013-028. Both parts are manufactured by API Delevan Inc. and share identical electrical and mechanical specifications across all critical parameters: power rating, voltage levels, current capacity, core type, mounting configuration, and physical dimensions.

The primary distinction between the original and substitute is product status and regulatory compliance. The 6013-028 is obsolete and RoHS non-compliant. The 6013R-028 is in active production and ROHS3 compliant, making it suitable for new designs and applications requiring current regulatory adherence.

For applications where the original 6013-028 was specified, the 6013R-028 provides full functional and mechanical compatibility with the added benefit of current manufacturing availability and improved environmental compliance.

Frequently Asked Questions (FAQ)

Q: Can the 6013R-028 be used as a direct replacement for the 6013-028 in existing designs?

A: Yes. The 6013R-028 is electrically and mechanically identical to the 6013-028. All voltage levels, current ratings, power capacity, core type, mounting method, termination style, and physical dimensions match exactly. The substitute can be installed without circuit modification or PCB redesign.

Q: What is the difference between the 6013-028 and 6013R-028?

A: The primary differences are product status and regulatory compliance. The 6013-028 is obsolete and RoHS non-compliant. The 6013R-028 is in active production and ROHS3 compliant. All electrical and mechanical parameters are identical.

Q: Are there any compatibility concerns when switching from 6013-028 to 6013R-028?

A: No compatibility concerns exist. Both transformers feature identical through-hole PC pin termination, matching footprints, and identical electrical performance across all operating parameters.

Q: Why should I choose the 6013R-028 over the 6013-028?

A: The 6013R-028 is the recommended choice because it is in active production with current availability, meets ROHS3 environmental compliance standards, and maintains full electrical and mechanical compatibility with the original specification.

Q: What are the key electrical parameters that define substitution for this transformer?

A: Substitution is determined by matching: primary voltage (115V), secondary voltage configuration (14V parallel / 28V series), secondary current capacity (170mA parallel / 85mA series), power rating (2.4VA), isolation voltage (2500Vrms), and winding configuration (single primary, dual secondary, no center tap).

Q: What are the key mechanical parameters that define substitution for this transformer?

A: Substitution requires matching: core type (laminated), mounting type (through hole), termination style (PC pin), physical dimensions (34.93mm L × 28.58mm W), and maximum seated height (30.15mm).

Request Quote (Ships tomorrow)