5TTP 3-R Equivalent & Substitute Parts
Part Overview
The 5TTP 3-R is a 3A 250VAC glass cartridge fuse manufactured by Bel Fuse Inc., designed for through-hole mounting in 5mm x 20mm form factor applications. This slow-blow fuse is actively produced and widely used in industrial and consumer electronics for circuit protection. Substitute parts are identified when equivalent electrical and mechanical parameters align with the original specification, ensuring functional interchangeability in the target application.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Current Rating | 3 A |
| Voltage Rating (AC) | 250 V |
| Fuse Type | Cartridge, Glass |
| Response Time | Slow Blow |
| Package / Case | 5mm x 20mm (Axial) |
| Mounting Type | Through Hole |
| Breaking Capacity @ Rated Voltage | 100 A |
| Operating Temperature Range | -55°C ~ 125°C |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the 5TTP 3-R is determined by strict alignment of the following parameters:
- Current Rating: 3 A (exact match required)
- Voltage Rating (AC): 250 V (exact match required)
- Fuse Type: Cartridge, Glass (exact match required)
- Response Time: Slow Blow (exact match required)
- Package / Case: 5mm x 20mm (Axial) (exact match required)
- Mounting Type: Through Hole (exact match required)
- Breaking Capacity @ Rated Voltage: 100 A (exact match required)
- Operating Temperature Range: -55°C ~ 125°C (exact match required)
- RoHS Status: ROHS3 Compliant (exact match required)
The substitute part 0239003.HXEP (Littelfuse Inc., Series 239) meets all mandatory electrical and mechanical parameters for direct substitution.
Parameter Comparison
| Parameter | 5TTP 3-R (Bel Fuse Inc.) | 0239003.HXEP (Littelfuse Inc.) |
|---|---|---|
| Current Rating (Amps) | 3 A | 3 A |
| Voltage Rating - AC | 250 V | 250 V |
| Fuse Type | Cartridge, Glass | Cartridge, Glass |
| Response Time | Slow Blow | Slow Blow |
| Package / Case | 5mm x 20mm (Axial) | 5mm x 20mm (Axial) |
| Mounting Type | Through Hole | Through Hole |
| Breaking Capacity @ Rated Voltage | 100 A | 100 A |
| Operating Temperature Range | -55°C ~ 125°C | -55°C ~ 125°C |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Size / Dimension | 0.217" Dia x 0.827" L (5.50mm x 21.00mm) | 0.217" Dia x 0.846" L (5.50mm x 21.50mm) |
| DC Cold Resistance | 0.043 Ohms | 0.04877 Ohms |
| Approval Agency | CE, CSA, cULus, PSE | CE, CSA, KC, PSE, UL |
Engineering Selection Recommendations
The 0239003.HXEP from Littelfuse Inc. is a direct electrical and mechanical equivalent to the 5TTP 3-R. Both parts are actively produced and carry ROHS3 compliance. The substitute part carries additional regulatory approvals (KC, UL) beyond the original specification. Physical dimensions differ marginally (0.019" length difference), which remains within typical through-hole PCB tolerance specifications. Both parts satisfy identical electrical performance criteria for 3A 250VAC slow-blow cartridge fuse applications.
Frequently Asked Questions (FAQ)
Q: Can the 0239003.HXEP replace the 5TTP 3-R in existing designs?
A: Yes. Both parts share identical electrical ratings (3A, 250VAC), fuse type (cartridge, glass), response characteristic (slow blow), package dimensions (5mm x 20mm), and mounting method (through hole). The 0.019" length difference is within standard PCB hole tolerance.
Q: Are there differences in approval certifications?
A: The 0239003.HXEP carries CE, CSA, KC, PSE, and UL approvals. The 5TTP 3-R carries CE, CSA, cULus, and PSE approvals. Both meet the same core safety standards for this product category.
Q: What is the significance of the DC Cold Resistance difference?
A: The DC Cold Resistance values (0.043 Ohms vs. 0.04877 Ohms) are within acceptable tolerance for slow-blow cartridge fuses and do not affect functional interchangeability in standard circuit protection applications.
Q: Are both parts currently available?
A: Yes. The 5TTP 3-R has 1412 pieces in stock. The 0239003.HXEP has 1014 pieces in stock.
Q: What is the Melting I²t specification used for?
A: Melting I²t defines the thermal energy required to melt the fuse element. While the values differ (55.6 vs. 129.51), both parts maintain identical current ratings and response times, confirming their equivalence for the specified 3A slow-blow application.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts