5TT 200-R Glass Cartridge Fuse Equivalent & Substitute Parts

Part Overview

The 5TT 200-R is a 200 mA, 250 V AC/DC slow-blow glass cartridge fuse manufactured by Bel Fuse Inc. in a 5mm x 20mm package format. This fuse is designed for circuit protection in applications requiring holder-mounted cartridge fuses with slow-blow response characteristics. The part maintains Active product status with 1583 units in current inventory.

Equivalent and substitute parts are necessary when the primary part becomes unavailable, when alternative sourcing is required for supply chain optimization, or when design flexibility permits selection from multiple qualified manufacturers meeting identical electrical and mechanical specifications.

Substiute Parts

5TT 200-R
Bel Fuse Inc.In Stock: 16505TT 200-R Datasheet
5TT 200-R
Current Part
5ST 200-R
Bel Fuse Inc.In Stock: 30095ST 200-R Datasheet
5ST 200-R
Parametric Equivalent
0239.200MXP
Littelfuse Inc.In Stock: 21940239.200MXP Datasheet
0239.200MXP
Direct
0034.3110
SCHURTER Inc.In Stock: 23600034.3110 Datasheet
0034.3110
Similar
0034.5610.11
SCHURTER Inc.In Stock: 10440034.5610.11 Datasheet
0034.5610.11
Similar
0218.200HXP
Littelfuse Inc.In Stock: 23820218.200HXP Datasheet
0218.200HXP
Similar
0218.200MXP
Littelfuse Inc.In Stock: 40760218.200MXP Datasheet
0218.200MXP
Similar
0219.200MXAP
Littelfuse Inc.In Stock: 24440219.200MXAP Datasheet
0219.200MXAP
Similar
0239.200HXP
Littelfuse Inc.In Stock: 16500239.200HXP Datasheet
0239.200HXP
Similar
BK/GMD-200-R
Eaton - Electronics DivisionIn Stock: 904BK/GMD-200-R Datasheet
BK/GMD-200-R
Similar
BK/S506-200-R
Eaton - Electronics DivisionIn Stock: 1292BK/S506-200-R Datasheet
BK/S506-200-R
Similar
BK1/S506-200-R
Eaton - Electronics DivisionIn Stock: 1772BK1/S506-200-R Datasheet
BK1/S506-200-R
Similar
GDC-200MA
Eaton - Electronics DivisionIn Stock: 1231GDC-200MA Datasheet
GDC-200MA
Similar
S506-200-R
Eaton - Electronics DivisionIn Stock: 1229S506-200-R Datasheet
S506-200-R
Similar

Key Parameters

Parameter Value
Current Rating 200 mA
Voltage Rating (AC) 250 V
Fuse Type Cartridge, Glass
Response Time Slow Blow
Package / Case 5mm x 20mm
Mounting Type Requires Holder
Operating Temperature Range -55°C ~ 125°C
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the 5TT 200-R is determined by strict equivalence across the following critical parameters:

  • Current Rating: 200 mA (exact match required)
  • Voltage Rating: 250 V AC (exact match required)
  • Fuse Type: Cartridge, Glass (exact match required)
  • Response Time: Slow Blow (exact match required)
  • Package / Case: 5mm x 20mm (exact match required)
  • Mounting Type: Requires Holder (exact match required)
  • Operating Temperature Range: -55°C ~ 125°C (minimum requirement)

All substitute parts listed below meet these mandatory electrical and mechanical parameters. Variations in secondary characteristics such as breaking capacity, melting I²t, DC cold resistance, and approval agency certifications do not disqualify parts from substitution eligibility when primary parameters align.

Parameter Comparison

Manufacturer Part Number Manufacturer Series Current Rating Voltage Rating (AC) Response Time Package / Case Breaking Capacity @ Rated Voltage Melting I²t DC Cold Resistance (Ohms) Approval Agencies
5TT 200-R Bel Fuse Inc. 5TT 200 mA 250 V Slow Blow 5mm x 20mm 100 A 0.476 4.98 CE, CSA, cULus
5ST 200-R Bel Fuse Inc. 5ST 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.15 2.9 CCC, CE, CSA, cURus, IMQ, SEMKO, VDE
0239.200MXP Littelfuse Inc. 239 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.165 3.8725 CE, CSA, KC, UL
0034.3110 SCHURTER Inc. FST 5x20 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.256 Not specified CCC, cURus, VDE
0034.5610.11 SCHURTER Inc. SMD-FST 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.256 Not specified cURus, VDE
0218.200HXP Littelfuse Inc. 218 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.341 1.6 CCC, CE, CSA, K-MARK, SEMKO, UL, VDE
0218.200MXP Littelfuse Inc. 218 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.341 1.6 CCC, CE, CSA, K-MARK, SEMKO, UL, VDE
0219.200MXAP Littelfuse Inc. 219XA 200 mA 250 V Slow Blow 5mm x 20mm 150 A 0.32 1.6 CCC, CE, CSA, SEMKO, UL, VDE
0239.200HXP Littelfuse Inc. 239 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.165 3.8725 CE, CSA, KC, UL
BK/GMD-200-R Eaton - Electronics Division GMD 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.2 5.19 CSA, UL
BK/S506-200-R Eaton - Electronics Division S506 200 mA 250 V Slow Blow 5mm x 20mm 35 A 0.114 1 BSI, CCC, CSA, IMQ, SEMKO, UR, VDE

Engineering Selection Recommendations

All listed substitute parts satisfy the mandatory electrical and mechanical parameters required for direct substitution with the 5TT 200-R. Selection among qualified alternatives should be based on the following factors:

Certification Coverage: The 5TT 200-R carries CE, CSA, and cULus approvals. Parts with broader certification portfolios (such as 0218.200HXP, 0218.200MXP, and BK/S506-200-R) provide expanded compliance coverage across additional regulatory jurisdictions including CCC, K-MARK, SEMKO, and VDE standards.

Inventory Availability: The 5ST 200-R (Bel Fuse Inc.) offers the highest current inventory at 2904 units, followed by 0218.200MXP (Littelfuse Inc.) at 3993 units. These options provide supply chain continuity when primary sourcing is constrained.

Manufacturer Qualification: Bel Fuse Inc., Littelfuse Inc., SCHURTER Inc., and Eaton Electronics Division are all established manufacturers with Active product status across their respective part lines, ensuring ongoing technical support and supply reliability.

Breaking Capacity Considerations: The 5TT 200-R specifies 100 A breaking capacity at rated voltage, which exceeds most substitute options at 35 A. The 0219.200MXAP variant offers 150 A breaking capacity for applications requiring enhanced fault current handling. Applications with specific breaking capacity requirements should verify compatibility with the selected substitute.

Frequently Asked Questions (FAQ)

Q: Can I substitute the 5TT 200-R with any of the listed parts without circuit redesign?

A: Yes. All listed substitute parts meet the mandatory electrical and mechanical parameters: 200 mA current rating, 250 V AC voltage rating, slow-blow response, 5mm x 20mm package, and holder-mount configuration. Direct substitution is permissible from an electrical standpoint. However, verify that your application does not have specific requirements for breaking capacity or DC cold resistance that would necessitate evaluation of secondary parameters.

Q: What is the difference between the 5TT 200-R and 5ST 200-R?

A: Both are Bel Fuse Inc. products with identical primary electrical specifications (200 mA, 250 V, slow-blow, 5x20mm). The 5TT series specifies 100 A breaking capacity and 0.476 melting I²t, while the 5ST series specifies 35 A breaking capacity and 0.15 melting I²t. The 5ST 200-R carries broader international certifications (CCC, IMQ, SEMKO, VDE) compared to the 5TT 200-R.

Q: Are there differences in physical dimensions between substitute parts?

A: All parts conform to the 5mm x 20mm package standard. Dimensional specifications list 0.201" to 0.205" diameter and 0.787" length across all variants, representing standard manufacturing tolerances within the cartridge fuse specification. Physical interchangeability in standard fuse holders is assured.

Q: Which substitute offers the best compliance coverage?

A: The 0218.200HXP, 0218.200MXP, and BK/S506-200-R parts carry the most comprehensive approval agency certifications. The 0218.200HXP and 0218.200MXP include CCC, CE, CSA, K-MARK, SEMKO, UL, and VDE approvals. The BK/S506-200-R includes BSI, CCC, CSA, IMQ, SEMKO, UR, and VDE approvals. Selection depends on your specific regulatory jurisdiction requirements.

Q: What does "slow-blow" response mean in the context of these fuses?

A: Slow-blow (also termed time-delay) fuses tolerate temporary inrush currents without opening, responding only to sustained overcurrent conditions. All listed parts share this characteristic, making them suitable for circuits with inductive loads or startup transients that would cause fast-acting fuses to nuisance-trip.

Q: Can I use a substitute with different DC cold resistance?

A: DC cold resistance variations (ranging from 1 Ohm to 5.19 Ohms across the listed parts) reflect manufacturing differences but do not affect fuse function in AC-rated applications. For DC applications or circuits sensitive to voltage drop across the fuse element, verify that the selected substitute's DC cold resistance is acceptable for your specific circuit design.

Request Quote (Ships tomorrow)