APEM 5632MAB Toggle Switch SPDT Equivalent & Substitute Parts

Part Overview

The APEM 5632MAB is an SPDT (Single Pole Double Throw) toggle switch rated for 6A at 125V AC and 4A at 30V DC. This panel-mount switch features a standard round actuator with solder lug termination and is designed for on-momentary operation. The component is actively manufactured and ROHS3 compliant, making it suitable for industrial control applications requiring reliable switching functionality. Substitute parts are identified when original inventory is unavailable or when design requirements permit operation within alternative electrical and mechanical specifications.

Substiute Parts

5632MAB
APEM Inc.In Stock: 11165632MAB Datasheet
5632MAB
Current Part
7108TZQE
C&KIn Stock: 7857108TZQE Datasheet
7108TZQE
Similar

Key Parameters

Parameter Value
Manufacturer Part Number 5632MAB
Manufacturer APEM Inc.
Series 5000M
Circuit Configuration SPDT
Switch Function On-Momentary
Current Rating (AC) 6A
Current Rating (DC) 4A
Voltage Rating (AC) 125V
Voltage Rating (DC) 30V
Mounting Type Panel Mount
Termination Style Solder Lug
Panel Cutout Diameter 12.50mm
Bushing Thread 15/32-32
Actuator Type Standard Round
Actuator Length 17.50mm
Operating Temperature Range -40°C to 85°C
Electrical Life 50,000 Cycles
RoHS Status ROHS3 Compliant
Product Status Active

Substitute Part Grouping Explanation

Substitution of the APEM 5632MAB with the C&K 7108TZQE is permissible based on the following alignment of critical electrical and mechanical parameters:

Electrical Compatibility:

  • Both parts feature SPDT circuit configuration with on-momentary switch function
  • Current ratings are compatible: 7108TZQE rated 5A (AC/DC) operates within the 6A AC specification of 5632MAB
  • Voltage ratings are compatible: 7108TZQE rated 120V AC and 28V DC are within or equivalent to 125V AC and 30V DC specifications
  • Both use solder lug termination

Mechanical Compatibility:

  • Both are panel-mount switches with standard round actuators
  • Actuator lengths are equivalent: 17.45mm (7108TZQE) versus 17.50mm (5632MAB)
  • Panel cutout dimensions are compatible: 11.91mm (7108TZQE) and 12.50mm (5632MAB) both accommodate standard 15/32-32 bushing threads
  • Both feature epoxy sealed terminals

Compliance Alignment:

  • Both are ROHS3 compliant
  • Both carry EAR99 ECCN classification
  • Both have MSL rating of 1 (Unlimited)

Parameter Comparison

Parameter APEM 5632MAB C&K 7108TZQE Compatibility Notes
Manufacturer APEM Inc. C&K Different manufacturers
Circuit Configuration SPDT SPDT Identical
Switch Function On-Momentary On-Momentary Identical
Current Rating (AC) 6A 5A 7108TZQE rated lower; acceptable for applications ≤5A
Current Rating (DC) 4A 5A 7108TZQE rated higher; compatible
Voltage Rating (AC) 125V 120V 7108TZQE rated lower; acceptable for applications ≤120V
Voltage Rating (DC) 30V 28V 7108TZQE rated lower; acceptable for applications ≤28V
Mounting Type Panel Mount Panel Mount Identical
Termination Style Solder Lug Solder Lug Identical
Panel Cutout Diameter 12.50mm 11.91mm Compatible; 11.91mm fits standard 12.50mm cutout
Bushing Thread 15/32-32 15/32-32 Identical
Actuator Type Standard Round Standard Round Identical
Actuator Length 17.50mm 17.45mm Functionally equivalent; 0.05mm difference negligible
Operating Temperature Range -40°C to 85°C -30°C to 85°C 5632MAB has wider low-temperature range
Electrical Life 50,000 Cycles 40,000 Cycles 5632MAB rated higher; 7108TZQE acceptable for ≤40,000 cycle applications
RoHS Status ROHS3 Compliant ROHS3 Compliant Identical
Product Status Active Active Both actively manufactured

Engineering Selection Recommendations

Primary Part (APEM 5632MAB): Use when applications require the full electrical specifications: 6A at 125V AC, 4A at 30V DC, extended low-temperature operation (-40°C), or 50,000 cycle electrical life. This part is actively manufactured with established supply availability.

Substitute Part (C&K 7108TZQE): Use when application requirements are within the following constraints: maximum 5A AC current, maximum 120V AC voltage, maximum 28V DC voltage, operating temperature minimum -30°C, and maximum 40,000 electrical cycles. This part is actively manufactured and ROHS3 compliant. The C&K 7108TZQE is suitable for applications where the lower electrical ratings and reduced cycle life do not impact system performance.

Compliance Considerations: Both parts are ROHS3 compliant and carry EAR99 ECCN classification. The 7108TZQE is REACH Affected, whereas the 5632MAB is REACH Unaffected. Regulatory requirements may influence selection in specific jurisdictions or end-use applications.

Frequently Asked Questions (FAQ)

Q: Can the C&K 7108TZQE directly replace the APEM 5632MAB in all applications?

A: No. The 7108TZQE has lower electrical ratings (5A AC vs. 6A AC; 120V AC vs. 125V AC; 28V DC vs. 30V DC) and reduced electrical life (40,000 cycles vs. 50,000 cycles). Substitution is valid only when application requirements fall within the 7108TZQE specifications.

Q: Are the panel cutout dimensions compatible?

A: Yes. The 7108TZQE has an 11.91mm panel cutout diameter, which is compatible with standard 12.50mm cutout openings. Both parts use the same 15/32-32 bushing thread, ensuring mechanical interchangeability in panel-mount installations.

Q: What is the difference in operating temperature range?

A: The APEM 5632MAB operates from -40°C to 85°C, while the C&K 7108TZQE operates from -30°C to 85°C. The 5632MAB is suitable for applications requiring extended low-temperature performance. If your application operates above -30°C, both parts are equivalent in this parameter.

Q: Are both parts RoHS compliant?

A: Yes, both the APEM 5632MAB and C&K 7108TZQE are ROHS3 compliant. However, the 7108TZQE is REACH Affected, while the 5632MAB is REACH Unaffected. Verify REACH compliance requirements for your specific application and jurisdiction.

Q: What is the significance of the 10,000-cycle difference in electrical life?

A: The APEM 5632MAB is rated for 50,000 electrical cycles, while the C&K 7108TZQE is rated for 40,000 cycles. For applications with high switching frequency or long operational life requirements, the 5632MAB provides additional margin. For applications with lower cycle counts, the 7108TZQE is acceptable.

Q: Can I use the 7108TZQE in a 6A application?

A: No. The C&K 7108TZQE is rated for a maximum of 5A AC current. Using it in a 6A application exceeds its electrical specification and may result in premature failure or safety hazards.

Request Quote (Ships tomorrow)