Request Quote
(Ships tomorrow)
Phoenix Contact 5437460 Terminal Block Header - Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 5437460 is a 6-position terminal block header with male pins, shrouded on 4 sides, designed for 90° right-angle through-hole mounting. This component features 0.200" (5.08mm) pitch spacing and is rated for 10A at 400V (IEC) or 12A at 300V (UL). The part is classified as obsolete, making identification of compatible substitutes essential for ongoing system maintenance and new design implementations where equivalent functionality is required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Number of Positions | 6 |
| Positions Per Level | 3 |
| Number of Levels | 2 |
| Pitch | 0.200" (5.08mm) |
| Header Orientation | 90°, Right Angle |
| Type | Header, Male Pins, Shrouded (4 Side) |
| Mounting Type | Through Hole |
| Termination Style | Solder |
| Current Rating (IEC) | 10A |
| Voltage Rating (IEC) | 400V |
| Contact Tail Length | 0.126" (3.20mm) |
| Insulation Height | 0.933" (23.70mm) |
| Material Flammability Rating | UL94 V-0 |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the Phoenix Contact 5437460 is determined by strict equivalence across the following critical parameters:
- Position Configuration: 6 positions arranged as 3 positions per level across 2 levels
- Pitch Spacing: 0.200" (5.08mm) center-to-center distance
- Connector Type: Male pin header with 4-side shrouding
- Orientation: 90° right-angle configuration
- Mounting Method: Through-hole solder termination
- Electrical Performance: Minimum 10A at 400V (IEC standard)
- Physical Dimensions: Contact tail length 0.126" (3.20mm) and insulation height 0.933" (23.70mm)
- Compliance: UL94 V-0 flammability rating and RoHS compliance
The Phoenix Contact 1842076 meets all substitution criteria across these parameters, providing functional and mechanical equivalence for direct replacement applications.
Parameter Comparison
| Parameter | 5437460 (Main Part) | 1842076 (Substitute) | Compatibility |
|---|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact | Same |
| Number of Positions | 6 | 6 | Equivalent |
| Positions Per Level | 3 | 3 | Equivalent |
| Number of Levels | 2 | 2 | Equivalent |
| Pitch | 0.200" (5.08mm) | 0.200" (5.08mm) | Equivalent |
| Header Orientation | 90°, Right Angle | 90°, Right Angle | Equivalent |
| Type | Header, Male Pins, Shrouded (4 Side) | Header, Male Pins, Shrouded (4 Side) | Equivalent |
| Mounting Type | Through Hole | Through Hole | Equivalent |
| Termination Style | Solder | Solder | Equivalent |
| Current - IEC | 10A | 10A | Equivalent |
| Voltage - IEC | 400V | 400V | Equivalent |
| Current - UL | 12A | 15A | Substitute Exceeds |
| Voltage - UL | 300V | 300V | Equivalent |
| Contact Mating Finish | Tin | Tin | Equivalent |
| Contact Tail Length | 0.126" (3.20mm) | 0.126" (3.20mm) | Equivalent |
| Insulation Height | 0.933" (23.70mm) | 0.933" (23.70mm) | Equivalent |
| Material Flammability Rating | UL94 V-0 | UL94 V-0 | Equivalent |
| RoHS Status | RoHS Compliant | RoHS Compliant | Equivalent |
| Product Status | Obsolete | Active | Substitute Active |
| Series | BCDH | COMBICON MDSTBA | Different Series |
| Housing Material | Polyamide (PA), Nylon | Polybutylene Terephthalate (PBT) | Different Material |
Engineering Selection Recommendations
The Phoenix Contact 1842076 is the qualified substitute for the obsolete 5437460 based on the following engineering criteria:
Electrical Equivalence: Both parts meet or exceed the IEC standard ratings of 10A at 400V. The 1842076 provides enhanced UL current rating (15A versus 12A), representing a performance margin that does not compromise compatibility.
Mechanical Compatibility: Identical pitch spacing (0.200"/5.08mm), contact tail length (0.126"/3.20mm), and insulation height (0.933"/23.70mm) ensure direct mechanical fit in existing PCB layouts and connector receptacles designed for the 5437460.
Compliance Status: Both components maintain UL94 V-0 flammability certification and RoHS compliance, satisfying regulatory requirements for industrial and commercial applications.
Product Availability: The 1842076 carries active product status with confirmed inventory availability, addressing the obsolescence constraint of the original 5437460.
Material Consideration: The substitute uses polybutylene terephthalate (PBT) housing versus polyamide (PA/nylon) in the original. PBT provides equivalent electrical performance with enhanced dimensional stability and chemical resistance, supporting long-term reliability in industrial environments.
Frequently Asked Questions (FAQ)
Q: Can the Phoenix Contact 1842076 be used as a direct replacement for the 5437460 in existing designs?
A: Yes. The 1842076 provides functional and mechanical equivalence across all critical parameters: 6-position configuration, 0.200" (5.08mm) pitch, 90° right-angle orientation, through-hole solder termination, and identical physical dimensions. No PCB layout modifications are required.
Q: What is the difference in housing material between these parts?
A: The 5437460 uses polyamide (PA/nylon) while the 1842076 uses polybutylene terephthalate (PBT). Both materials meet UL94 V-0 flammability requirements. PBT offers improved dimensional stability and chemical resistance, making it suitable for industrial applications with temperature cycling or exposure to solvents.
Q: Are the electrical ratings compatible?
A: Yes. Both parts meet the IEC standard of 10A at 400V. The 1842076 exceeds the UL rating of the original (15A versus 12A at 300V), providing additional current capacity margin without affecting compatibility.
Q: What does the "Side Stacking" feature on the 1842076 mean?
A: Side stacking capability allows multiple 1842076 connectors to be mounted adjacent to each other on a PCB without spacing gaps, enabling compact multi-connector assemblies. This feature does not affect direct replacement compatibility with the 5437460.
Q: Is the 1842076 RoHS compliant?
A: Yes. The 1842076 is RoHS compliant, matching the compliance status of the 5437460. Both parts are suitable for applications requiring RoHS certification.
Q: What is the inventory status of the substitute part?
A: The Phoenix Contact 1842076 is in active production with 1089 pieces confirmed in stock as new original inventory, ensuring availability for immediate procurement and deployment.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts