LED BLUE 1/4 HOLE PANEL MOUNT 5100H6 Equivalent & Substitute Parts

Part Overview

The VCC 5100H6 is a blue LED panel indicator designed for 1/4" (6.35mm) round panel cutouts with wire lead termination. This component features a 3.4V forward voltage rating, 50mA maximum current, and 3mcd brightness output with a 470nm peak wavelength. The 5100H6 is classified as obsolete, necessitating identification of functionally equivalent active alternatives for new designs and ongoing production requirements. Substitute parts must maintain mechanical compatibility with the 0.25" panel cutout specification and electrical performance within acceptable operating parameters.

Substiute Parts

5100H6
Visual Communications Company - VCCIn Stock: 11735100H6 Datasheet
5100H6
Current Part
SSI-LXH600USBD-150
Lumex Opto/Components Inc.In Stock: 2292SSI-LXH600USBD-150 Datasheet
SSI-LXH600USBD-150
Similar

Key Parameters

Parameter Specification Criticality for Substitution
Lamp Color Blue Critical - Color matching required
Panel Cutout Shape Round Critical - Mechanical fit
Panel Cutout Dimensions 0.25" (6.35mm) Critical - Physical compatibility
Termination Style Wire Leads - 6" (152.40mm) Critical - Electrical connection
Lens Style Round with Domed Top Important - Visual appearance
Voltage (Vf Typ) 3.4V Important - Circuit design compatibility
Current (If Max) 50mA Important - Power supply sizing
Wavelength - Peak 470nm Important - Color consistency
RoHS Status ROHS3 Compliant Important - Regulatory compliance

Substitute Part Grouping Explanation

Substitution of the VCC 5100H6 is based on the following critical parameters that must be maintained or exceeded:

Mechanical Compatibility Requirements:

  • Panel cutout shape must be round
  • Panel cutout dimensions must be 0.25" (6.35mm) to ensure proper fit in existing panel openings
  • Termination must be wire leads with 6" (152.40mm) length for circuit integration
  • Lens style must be round with domed top for visual consistency

Electrical Compatibility Requirements:

  • Lamp color must be blue (470nm peak wavelength)
  • Forward voltage (Vf) must be within acceptable circuit design parameters (3.4V to 3.5V range)
  • Maximum current (If) rating must support the application's current requirements
  • RoHS3 compliance required for regulatory adherence

Substitute Identification: The Lumex Opto/Components Inc. SSI-LXH600USBD-150 meets all critical mechanical and electrical compatibility criteria for direct substitution in the 5100H6 application.

Parameter Comparison

Parameter VCC 5100H6 (Main Part) Lumex SSI-LXH600USBD-150 (Substitute) Compatibility Status
Manufacturer Visual Communications Company - VCC Lumex Opto/Components Inc. Different manufacturer
Product Status Obsolete Active Substitute is actively produced
Type LED LED Compatible
Lamp Color Blue Blue Compatible
Lens Color Not specified Blue Substitute provides specification
Lens Transparency Not specified Diffused Substitute provides specification
Voltage (Vf Typ) 3.4V 3.5V Compatible - 0.1V difference
Current (If Max) 50mA 20mA Substitute has lower rating
Panel Cutout Shape Round Round Compatible
Panel Cutout Dimensions 0.25" (6.35mm) 0.25" (6.35mm) Compatible
Lens Size Not specified 5mm, T-1 3/4 Substitute provides specification
Lens Style Round with Domed Top Round with Domed Top Compatible
Millicandela Rating 3mcd 60mcd Substitute provides higher brightness
Wavelength - Peak 470nm 470nm Compatible
Viewing Angle Not specified 60° Substitute provides specification
Termination Style Wire Leads - 6" (152.40mm) Wire Leads - 6" (152.40mm) Compatible
RoHS Status ROHS3 Compliant ROHS3 Compliant Compatible
REACH Status REACH Unaffected REACH Unaffected Compatible
ECCN EAR99 EAR99 Compatible
HTSUS 8541.41.0000 8541.41.0000 Compatible

Engineering Selection Recommendations

Primary Substitute: Lumex SSI-LXH600USBD-150

The Lumex SSI-LXH600USBD-150 is the qualified substitute for the obsolete VCC 5100H6. Selection is based on the following engineering criteria:

Mechanical Compatibility: The substitute maintains identical panel cutout specifications (0.25" round) and wire lead termination (6" length), ensuring direct mechanical compatibility with existing panel designs and circuit board layouts.

Electrical Compatibility: Forward voltage differential of 0.1V (3.4V to 3.5V) is within acceptable circuit design tolerance for LED applications. The substitute's 20mA maximum current rating is lower than the original 50mA specification; circuit design must confirm that operating current does not exceed 20mA.

Regulatory Compliance: Both components maintain ROHS3 compliance and REACH unaffected status, satisfying regulatory requirements for new production and design transitions.

Product Status: The substitute is actively produced and stocked (2226 pcs available), providing supply chain continuity for the obsolete 5100H6.

Performance Enhancement: The substitute provides increased brightness (60mcd versus 3mcd) and specified viewing angle (60°), offering improved visual performance in panel indicator applications.

Frequently Asked Questions (FAQ)

Q: Can the Lumex SSI-LXH600USBD-150 be used as a direct replacement for the VCC 5100H6?

A: Yes, the Lumex SSI-LXH600USBD-150 is mechanically and electrically compatible for direct substitution. Both components feature identical 0.25" round panel cutouts, 6" wire lead termination, and blue 470nm wavelength specification. Forward voltage differs by 0.1V (3.4V to 3.5V), which is within acceptable tolerance for LED circuit design.

Q: What is the primary difference in electrical ratings between these components?

A: The main difference is maximum current rating. The VCC 5100H6 is rated for 50mA maximum current, while the Lumex SSI-LXH600USBD-150 is rated for 20mA maximum current. Circuit design must ensure operating current does not exceed 20mA when using the substitute.

Q: Are there mechanical fit concerns when substituting these parts?

A: No mechanical fit concerns exist. Both components have identical panel cutout specifications (0.25" round) and wire lead termination length (6"). The substitute's lens style (round with domed top) matches the original specification.

Q: Does the substitute meet the same regulatory requirements?

A: Yes, both components are ROHS3 compliant, REACH unaffected, and classified under the same ECCN (EAR99) and HTSUS (8541.41.0000) codes.

Q: Why does the substitute have higher brightness (60mcd versus 3mcd)?

A: The Lumex SSI-LXH600USBD-150 provides enhanced brightness output due to improved LED technology and diffused lens design. This represents a performance improvement for panel indicator visibility without affecting mechanical or electrical compatibility.

Q: What is the significance of the diffused lens in the substitute?

A: The diffused lens in the Lumex substitute provides a 60° viewing angle, distributing light more evenly across a wider field of view compared to the original specification. This improves visibility from multiple viewing angles in panel indicator applications.

Q: Is the 0.1V forward voltage difference significant for circuit design?

A: The 0.1V difference (3.4V to 3.5V) is within standard tolerance for LED circuit design. Most LED driver circuits and current-limiting resistor designs accommodate this variation without modification.

Q: What packaging format is the substitute supplied in?

A: The Lumex SSI-LXH600USBD-150 is supplied in bulk packaging, consistent with component procurement for production assembly.

Request Quote (Ships tomorrow)