Request Quote
(Ships tomorrow)
3M 4616-6200 Rectangular Connector Plug - Equivalent & Substitute Parts
Part Overview
The 3M 4616-6200 is a 16-position rectangular plug connector with IDC (Insulation Displacement Contact) termination, designed for discrete or ribbon cable applications with wire gauges of 26-28 AWG. This connector features gold-plated contacts, a 0.100" pitch configuration with 2-row layout, and latch lock/eject hook fastening. The part is Active status and widely used in industrial and telecommunications applications where reliable in-line connections are required. Substitute parts may be necessary due to inventory availability, project standardization, or specific fastening requirements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Connector Type | Plug |
| Number of Positions | 16 |
| Pitch | 0.100" (2.54mm) |
| Number of Rows | 2 |
| Row Spacing | 0.100" (2.54mm) |
| Cable Termination | IDC |
| Wire Gauge | 26-28 AWG, Stranded or Solid |
| Contact Finish | Gold |
| Mounting Type | Free Hanging (In-Line) |
Substitute Part Grouping Explanation
The 3M 4616-6000 qualifies as a direct substitute for the 4616-6200 based on the following critical parameters:
- Connector Type & Position Count: Both are 16-position plug connectors
- Pitch & Row Configuration: Identical 0.100" pitch with 2-row layout and 0.100" row spacing
- Cable Termination & Wire Gauge: Both support IDC termination with 26-28 AWG wire (stranded or solid)
- Contact Finish: Both feature gold-plated contacts with 30.0µin thickness
- Mounting & Features: Both are free-hanging in-line connectors with feed-through capability
- Compliance & Status: Both are Active status, ROHS3 compliant, REACH unaffected
The primary difference is the fastening type: the 4616-6200 includes latch lock/eject hooks (short), while the 4616-6000 has no specified fastening mechanism. This distinction does not affect electrical or mechanical compatibility for standard IDC ribbon cable applications.
Parameter Comparison
| Parameter | 4616-6200 (Main Part) | 4616-6000 (Substitute) |
|---|---|---|
| Manufacturer | 3M | 3M |
| Series | 4600 | 4600 |
| Connector Type | Plug | Plug |
| Contact Type | Male Pin | Male Pin |
| Number of Positions | 16 | 16 |
| Pitch | 0.100" (2.54mm) | 0.100" (2.54mm) |
| Number of Rows | 2 | 2 |
| Row Spacing | 0.100" (2.54mm) | 0.100" (2.54mm) |
| Mounting Type | Free Hanging (In-Line) | Free Hanging (In-Line) |
| Cable Termination | IDC | IDC |
| Wire Type | Discrete or Ribbon Cable | Discrete or Ribbon Cable |
| Wire Gauge | 26-28 AWG, Stranded or Solid | 26-28 AWG, Stranded or Solid |
| Features | Feed Through | Feed Through |
| Contact Finish | Gold | Gold |
| Contact Finish Thickness | 30.0µin (0.76µm) | 30.0µin (0.76µm) |
| Color | Gray | Gray |
| Product Status | Active | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
Both the 4616-6200 and 4616-6000 are Active status components from the 3M 4600 series, ensuring ongoing manufacturer support and availability. Both meet ROHS3 compliance requirements and carry REACH unaffected status, making them suitable for regulated applications in industrial and telecommunications sectors.
Selection between these parts should be based on fastening requirements: the 4616-6200 includes latch lock/eject hooks for applications requiring positive mechanical retention, while the 4616-6000 is suitable for applications where fastening is managed through external means or is not required. Both parts maintain identical electrical and mechanical specifications for IDC termination with 26-28 AWG cable.
Frequently Asked Questions (FAQ)
Q: Can the 4616-6000 directly replace the 4616-6200 in existing designs?
A: Yes, for applications where the latch lock/eject hook fastening of the 4616-6200 is not a functional requirement. Both connectors share identical pitch, row spacing, position count, contact finish, and IDC termination specifications. Verify that your application does not depend on the mechanical locking feature before substitution.
Q: What is the significance of the fastening type difference?
A: The 4616-6200 includes short latch lock/eject hooks for positive mechanical engagement, while the 4616-6000 has no specified fastening mechanism. This affects only the physical retention method and does not impact electrical performance or IDC contact compatibility.
Q: Are both parts suitable for ribbon cable applications?
A: Yes. Both the 4616-6200 and 4616-6000 support discrete or ribbon cable with 26-28 AWG wire gauge using IDC termination. Both feature feed-through capability for continuous signal routing.
Q: Do these connectors require any special handling or storage?
A: Both parts carry MSL Rating 1 (Unlimited), indicating no moisture sensitivity restrictions. Standard component storage practices apply.
Q: Are there any compliance differences between these parts?
A: No. Both parts are ROHS3 compliant, REACH unaffected, and carry identical ECCN (EAR99) and HTSUS classifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts