3M 4614-7001 Rectangular Connector Plug - Equivalent & Substitute Parts

Part Overview

The 3M 4614-7001 is a 14-position rectangular plug connector with IDC (Insulation Displacement Contact) termination, designed for 26-28 AWG wire gauges in both stranded and solid configurations. This connector features gold-plated contacts and is housed in a gray plastic body with a closed-end design.

The 4614-7001 is classified as obsolete. Locating active production alternatives is necessary for new designs, ongoing procurement, and system maintenance where component availability is critical.

Substiute Parts

4614-7001
3MIn Stock: 8734614-7001 Datasheet
4614-7001
Current Part
4614-6001
3MIn Stock: 12684614-6001 Datasheet
4614-6001
MFR Recommended

Key Parameters

Parameter Specification
Manufacturer Part Number 4614-7001
Manufacturer 3M
Category Rectangular Connectors
Series 4600
Connector Type Plug
Number of Positions 14
Pitch 0.100" (2.54mm)
Number of Rows 2
Row Spacing 0.100" (2.54mm)
Cable Termination IDC
Wire Gauge 26-28 AWG, Stranded or Solid
Contact Finish Gold
Contact Finish Thickness 30.0µin (0.76µm)
Color Gray
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

The 3M 4614-6001 qualifies as a direct substitute for the 4614-7001 based on the following critical parameters:

  • Connector Type & Position Count: Both are 14-position rectangular plugs
  • Pitch & Row Configuration: Identical 0.100" (2.54mm) pitch with 2-row layout and 0.100" row spacing
  • Cable Termination Method: Both use IDC termination technology
  • Wire Gauge Compatibility: Both accept 26-28 AWG wire in stranded or solid form
  • Contact System: Identical gold plating at 30.0µin (0.76µm) thickness
  • Electrical & Environmental Compliance: Both meet ROHS3 requirements and carry MSL 1 rating
  • Mechanical Fit: Same series (4600), connector type (plug), and mounting configuration (free hanging in-line)

The primary distinction is product status: the 4614-7001 is obsolete, while the 4614-6001 is active production. The 4614-6001 also features a feed-through design versus the closed-end design of the original part.

Parameter Comparison

Parameter 4614-7001 (Main Part) 4614-6001 (Substitute)
Manufacturer 3M 3M
Series 4600 4600
Connector Type Plug Plug
Number of Positions 14 14
Pitch 0.100" (2.54mm) 0.100" (2.54mm)
Number of Rows 2 2
Row Spacing 0.100" (2.54mm) 0.100" (2.54mm)
Cable Termination IDC IDC
Wire Gauge 26-28 AWG, Stranded or Solid 26-28 AWG, Stranded or Solid
Contact Finish Gold Gold
Contact Finish Thickness 30.0µin (0.76µm) 30.0µin (0.76µm)
Color Gray Gray
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)
Product Status Obsolete Active
End Design Closed End Feed Through

Engineering Selection Recommendations

The 3M 4614-6001 is the appropriate selection for applications currently using or specifying the 4614-7001. Both connectors maintain identical electrical and mechanical specifications across all critical parameters: position count, pitch, row spacing, wire gauge acceptance, contact finish, and compliance certifications.

The 4614-6001 carries active product status, ensuring ongoing availability and supply chain continuity. Both parts meet ROHS3 compliance requirements and carry MSL 1 ratings, confirming suitability for standard industrial and commercial environments without moisture sensitivity constraints.

The feed-through design of the 4614-6001 provides enhanced versatility in connector routing applications compared to the closed-end configuration of the original part, with no impact on core electrical or mechanical compatibility.

Frequently Asked Questions (FAQ)

Q: Can the 4614-6001 directly replace the 4614-7001 in existing assemblies?

A: Yes. Both connectors share identical pitch (0.100"), position count (14), row configuration (2 rows with 0.100" spacing), wire gauge compatibility (26-28 AWG), and contact specifications. Mechanical and electrical compatibility is confirmed across all specified parameters.

Q: What is the significance of the "closed end" versus "feed through" design difference?

A: The closed-end design of the 4614-7001 terminates the connector body at one end, while the feed-through design of the 4614-6001 allows connector routing through the assembly. This difference does not affect electrical performance or contact compatibility; selection depends on physical layout requirements.

Q: Are there compliance or environmental differences between these parts?

A: No. Both connectors are ROHS3 compliant and carry identical MSL 1 ratings. Environmental performance and regulatory compliance are equivalent.

Q: Why is the 4614-7001 listed as obsolete?

A: The 4614-7001 has been discontinued by 3M. The 4614-6001 represents the active production equivalent within the 4600 series, ensuring continued availability for new designs and ongoing procurement.

Q: Does packaging format affect substitution eligibility?

A: Packaging format (bulk versus other configurations) does not affect electrical or mechanical compatibility. The 4614-6001 is available in bulk packaging, suitable for standard procurement workflows.

Request Quote (Ships tomorrow)