Request Quote
(Ships tomorrow)
E-T-A 447-S-H-FN-125A Circuit Breaker Equivalent & Substitute Parts
Part Overview
The E-T-A 447-S-H-FN-125A is a thermal-magnetic circuit breaker rated for 125A at 28V DC, designed for chassis mount applications with push-to-reset actuation. This component is classified as obsolete, making identification of functionally equivalent alternatives necessary for system maintenance, repair, and new design implementations where this specific model is no longer available through standard distribution channels.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer Part Number | 447-S-H-FN-125A |
| Manufacturer | E-T-A |
| Series | 447 |
| Breaker Type | Thermal Magnetic |
| Current Rating | 125A |
| Voltage Rating (DC) | 28V |
| Mounting Type | Chassis Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Approval Agencies | CSA C22.2 No 235, UL1077 |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution for the 447-S-H-FN-125A requires matching the following critical parameters:
- Current Rating: 125A (exact match required)
- Voltage Rating: 28V DC (exact match required)
- Breaker Type: Thermal Magnetic (functional requirement)
- Mounting Type: Chassis Mount (mechanical requirement)
- Actuator Type: Push to Reset (operational requirement)
- Number of Poles: 1 (circuit configuration requirement)
- Approval Certifications: CSA C22.2 No 235 and/or UL1077 (regulatory compliance)
No substitute parts have been identified with the exact parameter specifications provided. The combination of 125A current rating, 28V DC voltage rating, thermal-magnetic operation, chassis mount configuration, and single-pole design with push-to-reset actuation represents a specific application requirement. Alternative sources should be evaluated based on these exact parameters.
Parameter Comparison
| Parameter | 447-S-H-FN-125A |
|---|---|
| Current Rating (Amps) | 125A |
| Voltage Rating - DC | 28V |
| Breaker Type | Thermal Magnetic |
| Mounting Type | Chassis Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
Engineering Selection Recommendations
The 447-S-H-FN-125A carries CSA C22.2 No 235 and UL1077 certifications, establishing compliance for aerospace and industrial applications. Given the obsolete status of this component, replacement selection must prioritize:
- Exact Parameter Matching: Current rating, voltage rating, and pole configuration must be identical to maintain circuit protection integrity.
- Certification Alignment: Substitute components must carry equivalent or superior certifications (CSA C22.2 No 235, UL1077, or equivalent standards).
- Mechanical Compatibility: Chassis mount configuration and push-to-reset actuation must be preserved to ensure installation compatibility.
- Thermal-Magnetic Operation: The protection mechanism must remain thermal-magnetic to maintain the original trip characteristics.
Frequently Asked Questions (FAQ)
Q: What makes a circuit breaker a valid substitute for the 447-S-H-FN-125A?
A: A valid substitute must match all critical parameters: 125A current rating, 28V DC voltage rating, thermal-magnetic operation, chassis mount configuration, push-to-reset actuation, single-pole design, and carry CSA C22.2 No 235 or UL1077 certification.
Q: Why is the 447-S-H-FN-125A classified as obsolete?
A: Obsolete status indicates the manufacturer has discontinued production. This necessitates sourcing from remaining inventory or identifying functionally equivalent alternatives from current production lines.
Q: Can a different current rating be used as a substitute?
A: No. The 125A current rating is a critical protection parameter. Substituting with a different amperage rating will alter circuit protection characteristics and compromise system safety.
Q: What is the significance of the 28V DC voltage rating?
A: The 28V DC rating specifies the maximum voltage the breaker can safely interrupt. This is a fundamental electrical parameter that cannot be altered without affecting breaker performance and safety compliance.
Q: Are there any packaging considerations for this component?
A: The 447-S-H-FN-125A is supplied as individual units. Packaging specifications were not provided in the technical parameters, so packaging compatibility should be verified during component procurement.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts