SCHURTER 4435.0352 Thermal Circuit Breaker 10A 240VAC 60VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4435.0352 is a thermal circuit breaker rated for 10A at 240V AC and 60V DC, featuring a rocker panel mount actuator with dual-pole configuration. This component is classified as Active product status and is ROHS3 compliant. Substitute parts are identified when equivalent electrical ratings, mechanical mounting specifications, and functional characteristics align with the original design requirements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4435.0352 |
| Manufacturer | SCHURTER Inc. |
| Series | TA35 |
| Breaker Type | Thermal |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitute parts for the 4435.0352 are qualified based on the following critical parameters:
- Current Rating: 10A (exact match required)
- Voltage Rating - AC: 240V (exact match required)
- Voltage Rating - DC: 60V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Rocker (exact match required)
- Number of Poles: 2 (exact match required)
- Product Status: Active (required for current availability)
- RoHS Status: ROHS3 Compliant (required for regulatory compliance)
All identified substitute parts meet these electrical and mechanical criteria. Variations in series designation (TA45 vs. TA35) and approval agency certifications do not affect functional equivalence for the specified application parameters.
Parameter Comparison
| Part Number | Series | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting | Actuator | Poles | Status | RoHS | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4435.0352 | TA35 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1171 |
| 4430.0022 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 890 |
| 4430.0413 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1180 |
| 4430.047 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1088 |
| 4430.0778 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1193 |
| 4430.0861 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1086 |
| 4430.0963 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1145 |
| 4430.1038 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 940 |
| 4430.1477 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1123 |
| 4430.1849 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 826 |
| 4430.1892 | TA45 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | 1268 |
Engineering Selection Recommendations
All substitute parts listed maintain Active product status and ROHS3 compliance, ensuring regulatory alignment with the original 4435.0352 specification. Selection among equivalent parts should be based on inventory availability and application-specific approval agency requirements. Parts with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications provide additional compliance documentation where required by regional standards.
Frequently Asked Questions (FAQ)
Q: Can I substitute a TA45 series part for the original TA35 series 4435.0352?
A: Yes. Both series maintain identical electrical ratings (10A, 240V AC, 60V DC), thermal breaker type, panel mount configuration, rocker actuator, and dual-pole design. Series designation does not affect functional equivalence for the specified parameters.
Q: Are all substitute parts ROHS3 compliant?
A: Yes. All listed substitute parts carry ROHS3 compliance status, matching the original part's regulatory requirement.
Q: What is the difference between parts with and without approval agency certifications?
A: Parts with documented approval agencies (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077) provide explicit certification documentation. Parts without listed certifications remain functionally equivalent but may require additional verification for applications with specific regional compliance mandates.
Q: Does inventory level affect substitution eligibility?
A: No. Inventory quantities do not determine substitution eligibility. All listed parts meet the electrical and mechanical criteria for direct substitution. Inventory levels are provided for procurement planning purposes only.
Q: Can I use these parts interchangeably in the same panel mount application?
A: Yes. All substitute parts share identical mounting type (panel mount), actuator type (rocker), and pole configuration (2-pole), ensuring mechanical and electrical interchangeability within the specified application parameters.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts