Request Quote
(Ships tomorrow)
SCHURTER 4435.0302 Circuit Breaker Thermal 16A 240VAC 32VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4435.0302 is an active thermal circuit breaker rated for 16A at 240V AC and 32V DC, featuring rocker panel mount actuation and single-pole configuration. This component is part of the TA35 series and maintains ROHS3 compliance with REACH unaffected status. Substitute parts are identified based on identical electrical ratings, mechanical mounting specifications, and regulatory compliance parameters to ensure direct functional equivalence in panel-mount circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer Part Number | 4435.0302 |
| Manufacturer | SCHURTER Inc. |
| Series | TA35 |
| Breaker Type | Thermal |
| Current Rating | 16A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 32V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 1 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
| Packaging | Bulk |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4435.0302 are qualified based on strict parametric equivalence across the following criteria:
- Current Rating: 16A (identical across all substitutes)
- Voltage Rating - AC: 240V (identical across all substitutes)
- Voltage Rating - DC: 32V (identical across all substitutes)
- Breaker Type: Thermal (identical across all substitutes)
- Mounting Type: Panel Mount (identical across all substitutes)
- Actuator Type: Rocker (identical across all substitutes)
- Number of Poles: 1 (identical across all substitutes)
- Series: TA35 (identical across all substitutes)
- RoHS Status: ROHS3 Compliant (identical across all substitutes)
- REACH Status: REACH Unaffected (identical across all substitutes)
All identified substitute parts maintain identical electrical performance specifications and mechanical form factors, enabling direct replacement without circuit redesign or panel modification.
Parameter Comparison
| Parameter | 4435.0302 | 4435.0209 | 4435.0282 | 4435.0301 | 4435.0478 |
|---|---|---|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. | SCHURTER Inc. | SCHURTER Inc. | SCHURTER Inc. |
| Series | TA35 | TA35 | TA35 | TA35 | TA35 |
| Breaker Type | Thermal | Thermal | Thermal | Thermal | Thermal |
| Current Rating (Amps) | 16A | 16A | 16A | 16A | 16A |
| Voltage Rating - AC | 240V | 240V | 240V | 240V | 240V |
| Voltage Rating - DC | 32V | 32V | 32V | 32V | 32V |
| Mounting Type | Panel Mount | Panel Mount | Panel Mount | Panel Mount | Panel Mount |
| Actuator Type | Rocker | Rocker | Rocker | Rocker | Rocker |
| Number of Poles | 1 | 1 | 1 | 1 | 1 |
| Product Status | Active | Active | Active | Active | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected |
| Packaging | Bulk | Bulk | Bulk | Bulk | Bulk |
Engineering Selection Recommendations
All substitute parts (4435.0209, 4435.0282, 4435.0301, 4435.0478) are active products with identical electrical and mechanical specifications to the primary part 4435.0302. Each maintains ROHS3 compliance and REACH unaffected status. Part 4435.0478 includes documented approval agency certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), providing additional regulatory documentation for applications requiring specific international standards compliance. Selection among equivalent parts may be based on inventory availability and specific certification requirements for the target application.
Frequently Asked Questions (FAQ)
Q: Can 4435.0209, 4435.0282, 4435.0301, and 4435.0478 be used interchangeably with 4435.0302?
A: Yes. All parts share identical current ratings (16A), voltage ratings (240V AC / 32V DC), breaker type (thermal), mounting configuration (panel mount rocker), pole count (1), and series designation (TA35). Direct substitution is supported without circuit or mechanical modifications.
Q: What determines substitution eligibility for these circuit breaker parts?
A: Substitution is based on matching electrical ratings (current and voltage), breaker type (thermal), mounting method (panel mount), actuator style (rocker), pole configuration (single-pole), and regulatory compliance status (ROHS3, REACH). All identified substitutes meet these criteria.
Q: Are there differences in regulatory certifications among the substitute parts?
A: Part 4435.0478 includes documented approval agency certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077). The primary part 4435.0302 and other substitutes do not list specific approval agencies in the provided data. Applications requiring explicit certification documentation should reference 4435.0478.
Q: Does packaging affect substitution compatibility?
A: All parts are supplied in bulk packaging. Packaging format does not affect electrical or mechanical compatibility for component selection purposes.
Q: What is the inventory status of substitute parts?
A: Current inventory levels are: 4435.0302 (1093 pcs), 4435.0209 (1054 pcs), 4435.0282 (960 pcs), 4435.0301 (851 pcs), and 4435.0478 (1045 pcs). Inventory availability may influence part selection for procurement planning.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts