SCHURTER 4435.024 Circuit Breaker Thermal Equivalent & Substitute Parts

Part Overview

The SCHURTER 4435.024 is a thermal circuit breaker rated for 240 V AC and 60 V DC operation with rocker panel mount actuation and dual-pole configuration. This part is classified as obsolete, necessitating identification of active equivalent alternatives that maintain identical electrical and mechanical specifications. Substitute parts must preserve the thermal protection mechanism, voltage ratings, mounting interface, and regulatory compliance certifications to ensure direct functional replacement in existing applications.

Substiute Parts

4435.024
SCHURTER Inc.In Stock: 10654435.024 Datasheet
4435.024
Current Part
4435.031
SCHURTER Inc.In Stock: 10264435.031 Datasheet
4435.031
MFR Recommended
4430.0617
SCHURTER Inc.In Stock: 9564430.0617 Datasheet
4430.0617
Parametric Equivalent
4430.0764
SCHURTER Inc.In Stock: 8594430.0764 Datasheet
4430.0764
Parametric Equivalent
4430.1147
SCHURTER Inc.In Stock: 12864430.1147 Datasheet
4430.1147
Parametric Equivalent
4430.1158
SCHURTER Inc.In Stock: 8734430.1158 Datasheet
4430.1158
Parametric Equivalent
4430.1204
SCHURTER Inc.In Stock: 9554430.1204 Datasheet
4430.1204
Parametric Equivalent
4430.1962
SCHURTER Inc.In Stock: 9294430.1962 Datasheet
4430.1962
Parametric Equivalent
4430.2087
SCHURTER Inc.In Stock: 6674430.2087 Datasheet
4430.2087
Parametric Equivalent
4430.2226
SCHURTER Inc.In Stock: 9324430.2226 Datasheet
4430.2226
Parametric Equivalent
4430.2487
SCHURTER Inc.In Stock: 11634430.2487 Datasheet
4430.2487
Parametric Equivalent
4430.2736
SCHURTER Inc.In Stock: 11134430.2736 Datasheet
4430.2736
Parametric Equivalent
4430.2781
SCHURTER Inc.In Stock: 9844430.2781 Datasheet
4430.2781
Parametric Equivalent
4430.2906
SCHURTER Inc.In Stock: 9004430.2906 Datasheet
4430.2906
Parametric Equivalent
4430.3172
SCHURTER Inc.In Stock: 8994430.3172 Datasheet
4430.3172
Parametric Equivalent
4430.3295
SCHURTER Inc.In Stock: 12034430.3295 Datasheet
4430.3295
Parametric Equivalent
4430.3331
SCHURTER Inc.In Stock: 9094430.3331 Datasheet
4430.3331
Parametric Equivalent
4430.3361
SCHURTER Inc.In Stock: 10334430.3361 Datasheet
4430.3361
Parametric Equivalent
4430.3471
SCHURTER Inc.In Stock: 11174430.3471 Datasheet
4430.3471
Parametric Equivalent
4430.3625
SCHURTER Inc.In Stock: 9574430.3625 Datasheet
4430.3625
Parametric Equivalent
4435.0014
SCHURTER Inc.In Stock: 11504435.0014 Datasheet
4435.0014
Parametric Equivalent
4435.0263
SCHURTER Inc.In Stock: 11644435.0263 Datasheet
4435.0263
Parametric Equivalent
4435.0305
SCHURTER Inc.In Stock: 9694435.0305 Datasheet
4435.0305
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 4435.024
Manufacturer SCHURTER Inc.
Series TA35
Product Status Obsolete
Breaker Type Thermal
Voltage Rating - AC 240 V
Voltage Rating - DC 60 V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
RoHS Status ROHS3 Compliant
Approval Agencies CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077

Substitute Part Grouping Explanation

Substitution of the SCHURTER 4435.024 is determined by strict equivalence across the following parameters:

  • Voltage Rating - AC: 240 V (mandatory match)
  • Voltage Rating - DC: 60 V (mandatory match)
  • Breaker Type: Thermal (mandatory match)
  • Mounting Type: Panel Mount (mandatory match)
  • Actuator Type: Rocker (mandatory match)
  • Number of Poles: 2 (mandatory match)
  • RoHS Status: ROHS3 Compliant (mandatory match)

Substitute parts are classified into two categories:

MFR Recommended: Active production parts explicitly designated as manufacturer-recommended replacements with current inventory availability.

Parametric Equivalent: Active or obsolete parts that match all mandatory electrical and mechanical parameters but may differ in series designation or regulatory compliance scope.

Parameter Comparison

Part Number Manufacturer Series Status Voltage AC Voltage DC Mounting Actuator Poles RoHS Inventory (Pcs)
4435.024 SCHURTER Inc. TA35 Obsolete 240 V 60 V Panel Mount Rocker 2 ROHS3 1027
4435.031 SCHURTER Inc. TA35 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 1009
4430.0617 SCHURTER Inc. TA45 Obsolete 240 V 60 V Panel Mount Rocker 2 ROHS3 931
4430.0764 SCHURTER Inc. TA45 Obsolete 240 V 60 V Panel Mount Rocker 2 ROHS3 768
4430.1147 SCHURTER Inc. TA45 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 1180
4430.1158 SCHURTER Inc. TA45 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 808
4430.1204 SCHURTER Inc. TA45 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 888
4430.1962 SCHURTER Inc. TA45 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 897
4430.2087 SCHURTER Inc. TA45 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 643
4430.2226 SCHURTER Inc. TA45 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 892
4430.2487 SCHURTER Inc. TA45 Active 240 V 60 V Panel Mount Rocker 2 ROHS3 1151

Engineering Selection Recommendations

Primary Substitute (MFR Recommended):

Part number 4435.031 is the manufacturer-designated replacement for 4435.024. Both parts share the TA35 series designation and active product status. Part 4435.031 carries full regulatory approval (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077) and maintains 1009 units in current inventory, ensuring supply continuity.

Secondary Substitutes (Parametric Equivalents - TA45 Series):

Parts 4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, and 4430.2487 are active production alternatives from the TA45 series. These parts match all mandatory electrical and mechanical parameters (240 V AC, 60 V DC, thermal operation, rocker actuation, dual-pole, panel mount, ROHS3 compliance). Series transition from TA35 to TA45 represents a product line evolution while maintaining functional equivalence. Parts 4430.1147, 4430.1204, and 4430.2226 carry full regulatory certifications. Inventory availability ranges from 643 to 1180 units.

Obsolete Alternatives (Not Recommended for New Designs):

Parts 4430.0617 and 4430.0764 are obsolete TA45 series equivalents. While parametrically equivalent, obsolete status precludes their use in new applications or long-term supply planning.

Frequently Asked Questions (FAQ)

Q: Can 4435.031 directly replace 4435.024 in existing installations?

A: Yes. Part 4435.031 is the manufacturer-recommended substitute with identical electrical ratings (240 V AC, 60 V DC), thermal protection mechanism, rocker actuation, dual-pole configuration, and panel mount interface. Both parts are ROHS3 compliant and carry equivalent regulatory certifications.

Q: What is the difference between TA35 and TA45 series parts?

A: TA35 and TA45 designate different product series within SCHURTER's thermal circuit breaker portfolio. Parts from both series that match the specified parameters (240 V AC, 60 V DC, thermal type, rocker actuator, 2 poles, panel mount) are parametrically equivalent for substitution purposes. Series designation does not affect electrical or mechanical compatibility when parameters are identical.

Q: Are TA45 series parts suitable substitutes for the obsolete 4435.024?

A: Yes, provided the application does not impose series-specific mechanical constraints. All TA45 alternatives listed (4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, 4430.2487) match the mandatory parameters. Active status ensures long-term availability. Verify mechanical fit within the panel mount cavity before deployment.

Q: Which substitute offers the best regulatory compliance coverage?

A: Parts 4435.031, 4430.1147, 4430.1204, and 4430.2226 carry full approval under CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. These parts are suitable for applications requiring comprehensive international regulatory certification.

Q: What inventory considerations apply to substitute selection?

A: The primary substitute 4435.031 maintains 1009 units in stock. Among TA45 alternatives, 4430.2487 offers the highest inventory (1151 units), followed by 4430.1147 (1180 units). For applications requiring immediate availability, these parts provide optimal supply security.

Q: Can obsolete parts 4430.0617 and 4430.0764 be used as substitutes?

A: While parametrically equivalent, obsolete status indicates discontinued production. These parts should not be selected for new designs or applications requiring long-term component availability. Use active alternatives instead.

Request Quote (Ships tomorrow)