Circuit Breaker Thermal 12A 240VAC 32VDC SCHURTER TA35 4435.0208

Part Overview

The SCHURTER 4435.0208 is a thermal circuit breaker designed for panel mount applications with a 12A current rating at 240V AC and 32V DC. This single-pole rocker-actuated breaker is classified as Active product status and maintains ROHS3 compliance. Alternative equivalent parts may be required due to inventory availability, supply chain considerations, or specific application requirements while maintaining identical electrical and mechanical specifications.

Substiute Parts

4435.0208
SCHURTER Inc.In Stock: 10654435.0208 Datasheet
4435.0208
Current Part
4435.0568
SCHURTER Inc.In Stock: 11554435.0568 Datasheet
4435.0568
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer Part Number 4435.0208
Manufacturer SCHURTER Inc.
Series TA35
Breaker Type Thermal
Current Rating 12A
Voltage Rating - AC 240V
Voltage Rating - DC 32V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 1
Product Status Active
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the SCHURTER 4435.0208 is determined by strict equivalence across the following critical parameters:

  • Current Rating: 12A
  • Voltage Rating AC: 240V
  • Voltage Rating DC: 32V
  • Breaker Type: Thermal
  • Mounting Type: Panel Mount
  • Actuator Type: Rocker
  • Number of Poles: 1
  • Series: TA35

Only parts matching all these parameters across the TA35 series are classified as parametric equivalents. The substitute part 4435.0568 satisfies all equivalence criteria and maintains identical functional and mechanical characteristics.

Parameter Comparison

Parameter 4435.0208 4435.0568 Match
Manufacturer SCHURTER Inc. SCHURTER Inc. Yes
Series TA35 TA35 Yes
Breaker Type Thermal Thermal Yes
Current Rating (Amps) 12A 12A Yes
Voltage Rating - AC 240V 240V Yes
Voltage Rating - DC 32V 32V Yes
Mounting Type Panel Mount Panel Mount Yes
Actuator Type Rocker Rocker Yes
Number of Poles 1 1 Yes
Product Status Active Active Yes
RoHS Status ROHS3 Compliant ROHS3 Compliant Yes

Engineering Selection Recommendations

Both the SCHURTER 4435.0208 and 4435.0568 are Active status products with full ROHS3 compliance. The 4435.0568 carries additional regulatory approvals including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications. Selection between these equivalent parts should be based on inventory availability, delivery requirements, and application-specific certification needs. Both parts are suitable for direct substitution in circuits requiring 12A thermal protection at 240V AC or 32V DC with panel mount rocker actuation.

Frequently Asked Questions (FAQ)

Q: Can the 4435.0568 directly replace the 4435.0208 in existing designs?

A: Yes. Both parts are parametric equivalents within the TA35 series with identical electrical ratings (12A, 240V AC, 32V DC), thermal breaker type, panel mount configuration, and rocker actuation. No circuit modifications are required.

Q: What are the key parameters that define substitution eligibility?

A: Substitution is valid when current rating, AC/DC voltage ratings, breaker type, mounting method, actuator type, pole count, and series designation remain unchanged. All these parameters are identical between the 4435.0208 and 4435.0568.

Q: Does the 4435.0568 have additional certifications?

A: Yes. The 4435.0568 includes CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 approvals. Applications requiring specific regional or standards-based certifications should reference these additional qualifications.

Q: Are there packaging differences between these parts?

A: Both parts are supplied in Bulk packaging. Inventory levels differ (1011 Pcs for 4435.0208 and 1090 Pcs for 4435.0568), but packaging format and handling specifications remain consistent.

Q: What compliance standards apply to both parts?

A: Both the 4435.0208 and 4435.0568 are ROHS3 compliant, REACH unaffected, and classified under ECCN EAR99 with HTSUS code 8536.20.0020.