SCHURTER 4435.001 Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The SCHURTER 4435.001 is a thermal circuit breaker rated for 6A at 240V AC / 60V DC with rocker panel mount actuation and dual-pole configuration. This component is classified as Active product status and complies with international safety standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Equivalent substitute parts are available within the SCHURTER TA series to address inventory availability, supply chain continuity, or specific application requirements while maintaining identical electrical and mechanical specifications.

Substiute Parts

4435.001
SCHURTER Inc.In Stock: 10474435.001 Datasheet
4435.001
Current Part
4430.0012
SCHURTER Inc.In Stock: 7364430.0012 Datasheet
4430.0012
Parametric Equivalent
4430.0707
SCHURTER Inc.In Stock: 10104430.0707 Datasheet
4430.0707
Parametric Equivalent
4430.0991
SCHURTER Inc.In Stock: 10744430.0991 Datasheet
4430.0991
Parametric Equivalent
4430.1121
SCHURTER Inc.In Stock: 7724430.1121 Datasheet
4430.1121
Parametric Equivalent
4430.1251
SCHURTER Inc.In Stock: 7204430.1251 Datasheet
4430.1251
Parametric Equivalent
4430.1608
SCHURTER Inc.In Stock: 8924430.1608 Datasheet
4430.1608
Parametric Equivalent
4430.2215
SCHURTER Inc.In Stock: 10054430.2215 Datasheet
4430.2215
Parametric Equivalent
4430.2872
SCHURTER Inc.In Stock: 9434430.2872 Datasheet
4430.2872
Parametric Equivalent
4430.2931
SCHURTER Inc.In Stock: 10154430.2931 Datasheet
4430.2931
Parametric Equivalent
4430.3456
SCHURTER Inc.In Stock: 7354430.3456 Datasheet
4430.3456
Parametric Equivalent
4430.3552
SCHURTER Inc.In Stock: 10274430.3552 Datasheet
4430.3552
Parametric Equivalent
4435.0031
SCHURTER Inc.In Stock: 8744435.0031 Datasheet
4435.0031
Parametric Equivalent
4435.0042
SCHURTER Inc.In Stock: 16304435.0042 Datasheet
4435.0042
Parametric Equivalent
4435.0089
SCHURTER Inc.In Stock: 7674435.0089 Datasheet
4435.0089
Parametric Equivalent
4435.0278
SCHURTER Inc.In Stock: 8314435.0278 Datasheet
4435.0278
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer SCHURTER Inc.
Breaker Type Thermal
Current Rating 6A
Voltage Rating - AC 240V
Voltage Rating - DC 60V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Packaging Bulk
RoHS Status ROHS3 Compliant
Approval Agencies CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077

Substitute Part Grouping Explanation

All substitute parts listed maintain identical electrical and mechanical parameters as the primary part 4435.001. Substitution is based strictly on the following criteria:

  • Current Rating: 6A (all substitutes)
  • Voltage Rating: 240V AC / 60V DC (all substitutes)
  • Breaker Type: Thermal (all substitutes)
  • Mounting Type: Panel Mount (all substitutes)
  • Actuator Type: Rocker (all substitutes)
  • Number of Poles: 2 (all substitutes)
  • Approval Agencies: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 (all substitutes)
  • RoHS Status: ROHS3 Compliant (all substitutes)

The substitute parts are drawn from the SCHURTER TA45 series, which shares identical functional specifications with the TA35 series primary part. All parts are Active product status and available in bulk packaging.

Parameter Comparison

Part Number Series Current Rating Voltage AC Voltage DC Breaker Type Mounting Actuator Poles RoHS Inventory (Pcs)
4435.001 TA35 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 1011
4430.0012 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 662
4430.0707 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 926
4430.0991 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 1026
4430.1121 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 686
4430.1251 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 705
4430.1608 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 875
4430.2215 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 943
4430.2872 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 836
4430.2931 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 934
4430.3456 TA45 6A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 718

Engineering Selection Recommendations

All listed substitute parts are functionally equivalent to the primary part 4435.001 based on electrical ratings, mechanical configuration, and regulatory compliance. Selection among these alternatives should be based on:

  • Product availability and inventory status
  • Supply chain lead times
  • Packaging requirements (all available in bulk)
  • Compliance certifications (all meet CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077)
  • RoHS compliance status (all ROHS3 compliant)

The TA45 series substitutes provide direct functional replacement with no derating or performance compromise relative to the TA35 series primary part.

Frequently Asked Questions (FAQ)

Q: Can TA45 series parts directly replace TA35 series parts?

A: Yes. The TA45 series substitute parts maintain identical electrical specifications (6A, 240V AC, 60V DC), mechanical configuration (panel mount, rocker actuator, dual-pole), and regulatory certifications as the TA35 series primary part.

Q: Are all substitute parts ROHS3 compliant?

A: Yes. All listed substitute parts carry ROHS3 Compliant status and are REACH Unaffected, matching the compliance profile of the primary part 4435.001.

Q: What approval agencies certify these circuit breakers?

A: All parts are certified by CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077.

Q: Are there differences in thermal response between the primary part and substitutes?

A: No. All parts are classified as thermal breakers with identical current ratings and voltage specifications. Thermal characteristics are equivalent across the TA35 and TA45 series for this 6A / 240V AC / 60V DC configuration.

Q: What is the difference between part numbers within the substitute list?

A: Part numbers differ based on internal SCHURTER manufacturing designations and configuration variants. All listed parts share identical electrical and mechanical parameters specified for this application.

Q: Can these parts be used in both AC and DC circuits?

A: Yes. All parts are rated for 240V AC and 60V DC operation, enabling use in dual-voltage applications within these specifications.

Request Quote (Ships tomorrow)