Request Quote
(Ships tomorrow)
SCHURTER 4430.366 Circuit Breaker Thermal 12A 240VAC 60VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.366 is a thermal circuit breaker rated for 12A at 240V AC and 60V DC, featuring a rocker actuator and panel mount configuration in the TA45 series. This component is active in production and complies with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical configuration, and regulatory compliance to ensure direct interchangeability in circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4430.366 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 12A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility is determined by strict equivalence across the following parameters:
- Current Rating: 12A
- Voltage Rating - AC: 240V
- Voltage Rating - DC: 60V
- Breaker Type: Thermal
- Mounting Type: Panel Mount
- Actuator Type: Rocker
- Number of Poles: 2
- Regulatory Compliance: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
All substitute parts listed maintain identical electrical and mechanical specifications to the main part number 4430.366. Parts are grouped by series designation: TA45 series substitutes provide direct equivalence, while TA35 series parts (4435.0092, 4435.0223) maintain all functional parameters with alternative series classification.
Parameter Comparison
| Part Number | Series | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting | Actuator | Poles | Product Status | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|
| 4430.366 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 982 |
| 4430.0024 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 813 |
| 4430.1034 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 1023 |
| 4430.1637 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 908 |
| 4430.242 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 1168 |
| 4430.2693 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 753 |
| 4430.3041 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 1126 |
| 4430.3223 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 884 |
| 4430.3263 | TA45 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 1096 |
| 4435.0092 | TA35 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 948 |
| 4435.0223 | TA35 | 12A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | Active | 924 |
Engineering Selection Recommendations
All listed substitute parts maintain active product status and ROHS3 compliance. TA45 series substitutes (4430.0024, 4430.1034, 4430.1637, 4430.242, 4430.2693, 4430.3041, 4430.3223, 4430.3263) provide direct series equivalence to the primary part 4430.366. TA35 series alternatives (4435.0092, 4435.0223) deliver identical electrical and mechanical performance with alternative series designation. Selection between TA45 and TA35 series depends on application-specific mechanical fit requirements and PCB layout constraints. All parts satisfy the same regulatory certifications: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077.
Frequently Asked Questions (FAQ)
Q: Can TA35 series parts replace TA45 series parts? A: Yes. Parts 4435.0092 and 4435.0223 maintain identical electrical ratings (12A, 240V AC, 60V DC), breaker type (thermal), mounting configuration (panel mount), actuator type (rocker), and pole count (2). Series designation reflects mechanical form factor; functional equivalence is confirmed.
Q: What determines if a part is a valid substitute? A: Substitution requires matching current rating (12A), AC voltage (240V), DC voltage (60V), breaker type (thermal), mounting type (panel mount), actuator type (rocker), and pole count (2). All listed parts meet these criteria.
Q: Are all substitute parts in stock? A: Inventory availability varies. Current stock levels are provided in the parameter comparison table. Verify availability with your supplier before component selection.
Q: Do all substitute parts comply with the same standards? A: TA45 series parts comply with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. TA35 series parts (4435.0092, 4435.0223) maintain ROHS3 compliance and equivalent electrical performance; verify specific certification requirements for your application.
Q: What is the difference between part numbers within the same series? A: All TA45 series parts share identical electrical and mechanical specifications. Part number variations reflect internal manufacturing or distribution designations and do not affect functional performance or interchangeability.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts