Request Quote
(Ships tomorrow)
SCHURTER 4430.3625 Thermal Circuit Breaker Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.3625 is a thermal circuit breaker rated for 240 V AC and 60 V DC operation with rocker panel mount actuation and dual-pole configuration. This part is classified as obsolete, making equivalent and substitute parts necessary for ongoing system maintenance and new design implementations. The TA45 series thermal breaker provides protection in applications requiring combined AC/DC voltage ratings with panel-mounted installation.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4430.3625 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Voltage Rating - AC | 240 V |
| Voltage Rating - DC | 60 V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Obsolete |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Affected |
Substitute Part Grouping Explanation
Substitution eligibility for the 4430.3625 is determined by the following critical parameters:
- Voltage Rating - AC: 240 V (required match)
- Voltage Rating - DC: 60 V (required match)
- Breaker Type: Thermal (required match)
- Mounting Type: Panel Mount (required match)
- Actuator Type: Rocker (required match)
- Number of Poles: 2 (required match)
- Series: TA45 (required match)
All substitute parts listed maintain identical electrical and mechanical specifications to the main part number. The primary distinction between substitutes is product status (active versus obsolete) and regulatory compliance documentation.
Parameter Comparison
| Part Number | Series | Voltage AC | Voltage DC | Breaker Type | Mounting | Actuator | Poles | Product Status | RoHS | REACH | Inventory |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4430.3625 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Obsolete | ROHS3 | REACH Affected | 942 Pcs |
| 4430.1051 | * | AC/DC | AC/DC | Thermal | — | — | — | Active | ROHS3 | REACH Unaffected | 830 Pcs |
| 4430.0617 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Obsolete | ROHS3 | REACH Affected | 931 Pcs |
| 4430.0764 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Obsolete | ROHS3 | REACH Affected | 768 Pcs |
| 4430.1147 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | REACH Unaffected | 1180 Pcs |
| 4430.1158 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | REACH Unaffected | 808 Pcs |
| 4430.1204 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | REACH Unaffected | 888 Pcs |
| 4430.1962 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | REACH Unaffected | 897 Pcs |
| 4430.2087 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | REACH Unaffected | 643 Pcs |
| 4430.2226 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | REACH Unaffected | 892 Pcs |
| 4430.2487 | TA45 | 240 V | 60 V | Thermal | Panel Mount | Rocker | 2 | Active | ROHS3 | REACH Unaffected | 1151 Pcs |
Engineering Selection Recommendations
For applications currently using the obsolete 4430.3625, direct parametric equivalents within the TA45 series include 4430.0617 and 4430.0764, which maintain identical electrical and mechanical specifications. However, these parts also carry obsolete status.
For new designs or long-term supply chain continuity, active-status alternatives are available: 4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, and 4430.2487. All active substitutes maintain the required 240 V AC / 60 V DC dual-voltage rating, thermal breaker operation, panel mount configuration, rocker actuation, and dual-pole design.
Parts 4430.1204, 4430.2226, and 4430.2487 carry documented approval agency certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), providing additional regulatory documentation for applications requiring formal compliance verification.
The MFR recommended part 4430.1051 is classified as a general AC/DC thermal circuit breaker with active status and REACH unaffected designation, though specific voltage and mounting parameters are not detailed in the provided data.
Frequently Asked Questions (FAQ)
Q: Can 4430.1051 directly replace 4430.3625?
A: 4430.1051 is designated as the MFR recommended substitute and carries active product status with REACH unaffected compliance. However, the provided data does not specify voltage ratings, mounting type, or pole configuration for 4430.1051. Confirmation of these parameters against your application requirements is necessary before selection.
Q: What is the difference between obsolete and active substitute parts?
A: Obsolete parts (4430.0617, 4430.0764) are no longer in active production but maintain identical specifications to 4430.3625. Active parts (4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, 4430.2487) are currently manufactured and represent the preferred choice for new installations and long-term supply assurance.
Q: Are all substitute parts ROHS3 compliant?
A: All listed substitute parts carry ROHS3 compliance status, matching the original 4430.3625 specification.
Q: What is the significance of REACH Affected versus REACH Unaffected status?
A: The original 4430.3625 carries REACH Affected status. Active substitutes carry REACH Unaffected status, indicating updated regulatory compliance. This distinction may be relevant for applications subject to REACH regulation requirements.
Q: Do all substitutes support the same 240 V AC / 60 V DC voltage ratings?
A: All parametric equivalents (4430.0617, 4430.0764, 4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, 4430.2487) maintain the identical 240 V AC and 60 V DC voltage ratings required for direct substitution. The MFR recommended part 4430.1051 does not specify these parameters in the provided data.
Q: Which substitutes carry formal approval agency certifications?
A: Parts 4430.1204, 4430.2226, and 4430.2487 include documented certifications from CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. These certifications provide formal regulatory documentation for applications requiring compliance verification.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts