SCHURTER 4430.3625 Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.3625 is a thermal circuit breaker rated for 240 V AC and 60 V DC operation with rocker panel mount actuation and dual-pole configuration. This part is classified as obsolete, making equivalent and substitute parts necessary for ongoing system maintenance and new design implementations. The TA45 series thermal breaker provides protection in applications requiring combined AC/DC voltage ratings with panel-mounted installation.

Substiute Parts

4430.3625
SCHURTER Inc.In Stock: 9574430.3625 Datasheet
4430.3625
Current Part
4430.1051
SCHURTER Inc.In Stock: 9404430.1051 Datasheet
4430.1051
MFR Recommended
4430.0617
SCHURTER Inc.In Stock: 9564430.0617 Datasheet
4430.0617
Parametric Equivalent
4430.0764
SCHURTER Inc.In Stock: 8594430.0764 Datasheet
4430.0764
Parametric Equivalent
4430.1147
SCHURTER Inc.In Stock: 12864430.1147 Datasheet
4430.1147
Parametric Equivalent
4430.1158
SCHURTER Inc.In Stock: 8734430.1158 Datasheet
4430.1158
Parametric Equivalent
4430.1204
SCHURTER Inc.In Stock: 9554430.1204 Datasheet
4430.1204
Parametric Equivalent
4430.1962
SCHURTER Inc.In Stock: 9294430.1962 Datasheet
4430.1962
Parametric Equivalent
4430.2087
SCHURTER Inc.In Stock: 6674430.2087 Datasheet
4430.2087
Parametric Equivalent
4430.2226
SCHURTER Inc.In Stock: 9324430.2226 Datasheet
4430.2226
Parametric Equivalent
4430.2487
SCHURTER Inc.In Stock: 11634430.2487 Datasheet
4430.2487
Parametric Equivalent
4430.2736
SCHURTER Inc.In Stock: 11134430.2736 Datasheet
4430.2736
Parametric Equivalent
4430.2781
SCHURTER Inc.In Stock: 9844430.2781 Datasheet
4430.2781
Parametric Equivalent
4430.2906
SCHURTER Inc.In Stock: 9004430.2906 Datasheet
4430.2906
Parametric Equivalent
4430.3172
SCHURTER Inc.In Stock: 8994430.3172 Datasheet
4430.3172
Parametric Equivalent
4430.3295
SCHURTER Inc.In Stock: 12034430.3295 Datasheet
4430.3295
Parametric Equivalent
4430.3331
SCHURTER Inc.In Stock: 9094430.3331 Datasheet
4430.3331
Parametric Equivalent
4430.3361
SCHURTER Inc.In Stock: 10334430.3361 Datasheet
4430.3361
Parametric Equivalent
4430.3471
SCHURTER Inc.In Stock: 11174430.3471 Datasheet
4430.3471
Parametric Equivalent
4435.0014
SCHURTER Inc.In Stock: 11504435.0014 Datasheet
4435.0014
Parametric Equivalent
4435.0263
SCHURTER Inc.In Stock: 11644435.0263 Datasheet
4435.0263
Parametric Equivalent
4435.0305
SCHURTER Inc.In Stock: 9694435.0305 Datasheet
4435.0305
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 4430.3625
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Voltage Rating - AC 240 V
Voltage Rating - DC 60 V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Product Status Obsolete
RoHS Status ROHS3 Compliant
REACH Status REACH Affected

Substitute Part Grouping Explanation

Substitution eligibility for the 4430.3625 is determined by the following critical parameters:

  • Voltage Rating - AC: 240 V (required match)
  • Voltage Rating - DC: 60 V (required match)
  • Breaker Type: Thermal (required match)
  • Mounting Type: Panel Mount (required match)
  • Actuator Type: Rocker (required match)
  • Number of Poles: 2 (required match)
  • Series: TA45 (required match)

All substitute parts listed maintain identical electrical and mechanical specifications to the main part number. The primary distinction between substitutes is product status (active versus obsolete) and regulatory compliance documentation.

Parameter Comparison

Part Number Series Voltage AC Voltage DC Breaker Type Mounting Actuator Poles Product Status RoHS REACH Inventory
4430.3625 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Obsolete ROHS3 REACH Affected 942 Pcs
4430.1051 * AC/DC AC/DC Thermal Active ROHS3 REACH Unaffected 830 Pcs
4430.0617 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Obsolete ROHS3 REACH Affected 931 Pcs
4430.0764 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Obsolete ROHS3 REACH Affected 768 Pcs
4430.1147 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Active ROHS3 REACH Unaffected 1180 Pcs
4430.1158 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Active ROHS3 REACH Unaffected 808 Pcs
4430.1204 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Active ROHS3 REACH Unaffected 888 Pcs
4430.1962 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Active ROHS3 REACH Unaffected 897 Pcs
4430.2087 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Active ROHS3 REACH Unaffected 643 Pcs
4430.2226 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Active ROHS3 REACH Unaffected 892 Pcs
4430.2487 TA45 240 V 60 V Thermal Panel Mount Rocker 2 Active ROHS3 REACH Unaffected 1151 Pcs

Engineering Selection Recommendations

For applications currently using the obsolete 4430.3625, direct parametric equivalents within the TA45 series include 4430.0617 and 4430.0764, which maintain identical electrical and mechanical specifications. However, these parts also carry obsolete status.

For new designs or long-term supply chain continuity, active-status alternatives are available: 4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, and 4430.2487. All active substitutes maintain the required 240 V AC / 60 V DC dual-voltage rating, thermal breaker operation, panel mount configuration, rocker actuation, and dual-pole design.

Parts 4430.1204, 4430.2226, and 4430.2487 carry documented approval agency certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), providing additional regulatory documentation for applications requiring formal compliance verification.

The MFR recommended part 4430.1051 is classified as a general AC/DC thermal circuit breaker with active status and REACH unaffected designation, though specific voltage and mounting parameters are not detailed in the provided data.

Frequently Asked Questions (FAQ)

Q: Can 4430.1051 directly replace 4430.3625?

A: 4430.1051 is designated as the MFR recommended substitute and carries active product status with REACH unaffected compliance. However, the provided data does not specify voltage ratings, mounting type, or pole configuration for 4430.1051. Confirmation of these parameters against your application requirements is necessary before selection.

Q: What is the difference between obsolete and active substitute parts?

A: Obsolete parts (4430.0617, 4430.0764) are no longer in active production but maintain identical specifications to 4430.3625. Active parts (4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, 4430.2487) are currently manufactured and represent the preferred choice for new installations and long-term supply assurance.

Q: Are all substitute parts ROHS3 compliant?

A: All listed substitute parts carry ROHS3 compliance status, matching the original 4430.3625 specification.

Q: What is the significance of REACH Affected versus REACH Unaffected status?

A: The original 4430.3625 carries REACH Affected status. Active substitutes carry REACH Unaffected status, indicating updated regulatory compliance. This distinction may be relevant for applications subject to REACH regulation requirements.

Q: Do all substitutes support the same 240 V AC / 60 V DC voltage ratings?

A: All parametric equivalents (4430.0617, 4430.0764, 4430.1147, 4430.1158, 4430.1204, 4430.1962, 4430.2087, 4430.2226, 4430.2487) maintain the identical 240 V AC and 60 V DC voltage ratings required for direct substitution. The MFR recommended part 4430.1051 does not specify these parameters in the provided data.

Q: Which substitutes carry formal approval agency certifications?

A: Parts 4430.1204, 4430.2226, and 4430.2487 include documented certifications from CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. These certifications provide formal regulatory documentation for applications requiring compliance verification.

Request Quote (Ships tomorrow)