Request Quote
(Ships tomorrow)
SCHURTER 4430.3456 Circuit Breaker Thermal 6A 240VAC 60VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.3456 is a thermal circuit breaker rated for 6A at 240V AC and 60V DC, featuring a rocker actuator and panel mount configuration in the TA45 series. This component is classified as Active product status and is ROHS3 compliant. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical mounting specifications, and operational characteristics to ensure direct interchangeability in panel-mounted circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer Part Number | 4430.3456 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 6A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| Packaging | Bulk |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4430.3456 are qualified based on the following critical parameters that determine functional interchangeability:
- Current Rating: 6A (exact match required)
- Voltage Rating - AC: 240V (exact match required)
- Voltage Rating - DC: 60V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Rocker (exact match required)
- Number of Poles: 2 (exact match required)
- Series: TA45 (exact match required)
- Manufacturer: SCHURTER Inc. (same manufacturer)
All substitute parts listed below meet these criteria and are classified as parametric equivalents within the TA45 series thermal circuit breaker family.
Parameter Comparison
| Part Number | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting Type | Actuator Type | Poles | Series | Product Status | RoHS Status | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4430.3456 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 718 |
| 4430.0012 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 662 |
| 4430.0707 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 926 |
| 4430.0991 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1026 |
| 4430.1121 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 686 |
| 4430.1251 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 705 |
| 4430.1608 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 875 |
| 4430.2215 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 943 |
| 4430.2872 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 836 |
| 4430.2931 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 934 |
| 4430.3552 | 6A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1006 |
Engineering Selection Recommendations
All substitute parts listed are Active product status components manufactured by SCHURTER Inc. within the TA45 series. Parts 4430.0012, 4430.0707, 4430.0991, 4430.1121, 4430.1251, 4430.1608, 4430.2215, and 4430.3552 carry regulatory approvals including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. All parts maintain ROHS3 compliance and are suitable for direct substitution in applications requiring 6A thermal circuit protection at 240V AC and 60V DC with panel mount rocker actuator configuration.
Frequently Asked Questions (FAQ)
Q: Can all listed substitute parts replace the SCHURTER 4430.3456 directly?
A: Yes. All substitute parts match the critical electrical and mechanical parameters: 6A current rating, 240V AC and 60V DC voltage ratings, thermal breaker type, panel mount configuration, rocker actuator, and 2-pole design within the TA45 series.
Q: What determines if a part is a valid substitute?
A: Substitution is based on exact matching of current rating (6A), AC voltage (240V), DC voltage (60V), breaker type (thermal), mounting type (panel mount), actuator type (rocker), pole count (2), and series designation (TA45).
Q: Are there differences in regulatory approvals among the substitute parts?
A: Parts 4430.0012, 4430.0707, 4430.0991, 4430.1121, 4430.1251, 4430.1608, 4430.2215, and 4430.3552 carry CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 approvals. Parts 4430.2872 and 4430.2931 are ROHS3 compliant without listed approval agency certifications in the provided data.
Q: What is the inventory status for substitute parts?
A: All substitute parts are available in bulk packaging with inventory ranging from 662 to 1026 pieces. Part 4430.0991 has the highest inventory at 1026 pieces, while 4430.0012 has the lowest at 662 pieces.
Q: Are all parts ROHS3 compliant?
A: Yes. All listed parts, including the main part 4430.3456 and all substitutes, are ROHS3 compliant.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts