SCHURTER 4430.3375 Thermal Circuit Breaker Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.3375 is a thermal circuit breaker rated for 5A at 240V AC / 60V DC with rocker panel mount actuation. This TA45 series breaker is an active product with full compliance to CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. The device features a 2-pole configuration and ROHS3 compliance. Equivalent part numbers within the TA45 series provide direct functional substitution when the primary part number is unavailable or when inventory optimization is required.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 5A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Packaging | Bulk |
| RoHS Status | ROHS3 Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
All substitute parts listed maintain identical electrical and mechanical parameters as the primary part 4430.3375. Substitution is valid based on the following criteria:
- Current Rating: 5A (all substitutes)
- Voltage Rating: 240V AC / 60V DC (all substitutes)
- Breaker Type: Thermal (all substitutes)
- Mounting Configuration: Panel Mount, Rocker Actuator, 2-Pole (all substitutes)
- Series: TA45 (all substitutes)
- Regulatory Compliance: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 (all substitutes)
- Environmental Status: ROHS3 Compliant, REACH Unaffected (all substitutes)
These part numbers are parametric equivalents within the same product family and can be selected interchangeably for applications requiring the specified electrical and mechanical characteristics.
Parameter Comparison
| Part Number | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting Type | Actuator | Poles | Series | Inventory (Pcs) | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|
| 4430.3375 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 838 | Active |
| 4430.0586 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 967 | Active |
| 4430.0847 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 803 | Active |
| 4430.0977 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 1065 | Active |
| 4430.1201 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 1518 | Active |
| 4430.1353 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 1131 | Active |
| 4430.1384 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 1070 | Active |
| 4430.1564 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 835 | Active |
| 4430.1856 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 1186 | Active |
| 4430.1926 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 722 | Active |
| 4430.2297 | 5A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | 964 | Active |
Engineering Selection Recommendations
All listed substitute parts are active products with full regulatory compliance to CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Selection among equivalent part numbers should be based on inventory availability and supply chain requirements. Part 4430.1201 offers the highest current inventory level at 1518 units. All substitutes maintain ROHS3 compliance and REACH unaffected status, ensuring environmental and regulatory alignment with the primary part specification.
Frequently Asked Questions (FAQ)
Q: Can all listed part numbers be used interchangeably with 4430.3375?
A: Yes. All substitute parts maintain identical electrical ratings (5A, 240V AC, 60V DC), mechanical configuration (panel mount, rocker actuator, 2-pole), and regulatory certifications. They are parametric equivalents within the TA45 series.
Q: What determines if a part is a valid substitute?
A: Substitution validity is determined by matching current rating, voltage ratings (AC and DC), breaker type (thermal), mounting type (panel mount), actuator type (rocker), pole count (2), and series designation (TA45). All listed parts meet these criteria.
Q: Are there differences in thermal response characteristics between these part numbers?
A: The provided specifications do not include thermal response time or trip curve data. All parts are classified as thermal breakers within the TA45 series with identical electrical ratings.
Q: Do all substitutes carry the same regulatory approvals?
A: All listed substitutes carry CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 compliance. All are ROHS3 compliant and REACH unaffected.
Q: Which part number should I select if multiple are available?
A: Selection should be based on inventory availability and supply chain logistics. Part 4430.1201 currently has the highest inventory level. All parts are functionally equivalent for the specified application.
Q: Is packaging identical across all part numbers?
A: All substitute parts are supplied in bulk packaging, consistent with the primary part specification.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts