SCHURTER 4430.3361 Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.3361 is a thermal circuit breaker rated for 240 V AC and 60 V DC operation with rocker panel mount actuation and dual-pole configuration. This component is classified as Active product status with full compliance to CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. Identifying equivalent and substitute parts is necessary when addressing inventory constraints, supply chain disruptions, or design flexibility requirements while maintaining identical electrical and mechanical specifications.

Substiute Parts

4430.3361
SCHURTER Inc.In Stock: 10334430.3361 Datasheet
4430.3361
Current Part
4430.0617
SCHURTER Inc.In Stock: 9564430.0617 Datasheet
4430.0617
Parametric Equivalent
4430.0764
SCHURTER Inc.In Stock: 8594430.0764 Datasheet
4430.0764
Parametric Equivalent
4430.1147
SCHURTER Inc.In Stock: 12864430.1147 Datasheet
4430.1147
Parametric Equivalent
4430.1158
SCHURTER Inc.In Stock: 8734430.1158 Datasheet
4430.1158
Parametric Equivalent
4430.2487
SCHURTER Inc.In Stock: 11634430.2487 Datasheet
4430.2487
Parametric Equivalent
4430.2736
SCHURTER Inc.In Stock: 11134430.2736 Datasheet
4430.2736
Parametric Equivalent
4430.2781
SCHURTER Inc.In Stock: 9844430.2781 Datasheet
4430.2781
Parametric Equivalent
4430.2906
SCHURTER Inc.In Stock: 9004430.2906 Datasheet
4430.2906
Parametric Equivalent
4430.3172
SCHURTER Inc.In Stock: 8994430.3172 Datasheet
4430.3172
Parametric Equivalent
4430.3295
SCHURTER Inc.In Stock: 12034430.3295 Datasheet
4430.3295
Parametric Equivalent
4430.3331
SCHURTER Inc.In Stock: 9094430.3331 Datasheet
4430.3331
Parametric Equivalent
4430.3471
SCHURTER Inc.In Stock: 11174430.3471 Datasheet
4430.3471
Parametric Equivalent
4430.3625
SCHURTER Inc.In Stock: 9574430.3625 Datasheet
4430.3625
Parametric Equivalent
4435.0014
SCHURTER Inc.In Stock: 11504435.0014 Datasheet
4435.0014
Parametric Equivalent
4435.0263
SCHURTER Inc.In Stock: 11644435.0263 Datasheet
4435.0263
Parametric Equivalent
4435.0305
SCHURTER Inc.In Stock: 9694435.0305 Datasheet
4435.0305
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Voltage Rating - AC 240 V
Voltage Rating - DC 60 V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Packaging Bulk
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for SCHURTER TA45 series thermal circuit breakers is determined by strict equivalence across the following parameters: voltage rating (240 V AC / 60 V DC), breaker type (thermal), mounting configuration (panel mount rocker), pole count (2-pole), and series designation (TA45). All substitute parts listed maintain identical electrical specifications and mechanical form factors. Product status variations (Active vs. Obsolete) and compliance certifications are documented to support engineering selection decisions but do not disqualify substitution based on functional equivalence.

Parameter Comparison

Part Number Manufacturer Series Breaker Type Voltage AC Voltage DC Mounting Type Actuator Poles Product Status Inventory (Pcs)
4430.3361 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 970
4430.0617 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Obsolete 931
4430.0764 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Obsolete 768
4430.1147 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 1180
4430.1158 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 808
4430.2487 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 1151
4430.2736 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 1097
4430.2781 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 904
4430.2906 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 818
4430.3172 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 800
4430.3295 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount Rocker 2 Active 1160

Engineering Selection Recommendations

All listed substitute parts maintain functional equivalence to the primary part 4430.3361 across electrical and mechanical specifications. Active status parts (4430.1147, 4430.1158, 4430.2487, 4430.2736, 4430.2781, 4430.2906, 4430.3172, 4430.3295) are preferred for new designs and ongoing production due to current product lifecycle status. Parts 4430.0617 and 4430.0764 carry Obsolete designation and should be reserved for legacy system maintenance or retrofit applications where continuity with existing installations is required.

Compliance certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077) are documented for the primary part 4430.3361 and active substitute parts 4430.1147, 4430.2487, 4430.2781, and 4430.2906. REACH status varies between REACH Unaffected (preferred) and REACH Affected designations; review regulatory requirements for your application jurisdiction.

Frequently Asked Questions (FAQ)

Q: Can obsolete parts 4430.0617 and 4430.0764 be used as direct replacements for 4430.3361?

A: Yes, from an electrical and mechanical standpoint. Both parts share identical voltage ratings (240 V AC / 60 V DC), thermal breaker type, 2-pole rocker panel mount configuration, and TA45 series designation. However, obsolete status indicates discontinued production; use only when inventory availability or legacy system requirements justify the selection.

Q: What is the difference between Active and Obsolete product status?

A: Active parts are in current production with ongoing manufacturer support. Obsolete parts are no longer manufactured but may remain available through existing inventory channels. For new designs, select Active status parts to ensure long-term supply chain stability.

Q: Are all substitute parts ROHS3 compliant?

A: Yes, all listed parts carry ROHS3 Compliant designation, meeting hazardous substance restrictions across all listed substitute options.

Q: Does REACH status affect substitution eligibility?

A: REACH status indicates regulatory substance compliance requirements. REACH Unaffected parts (4430.3361, 4430.1147, 4430.1158, 4430.2487, 4430.2736, 4430.2781, 4430.2906, 4430.3172, 4430.3295) are preferred for applications subject to EU chemical regulations. REACH Affected parts (4430.0617, 4430.0764) require compliance verification for your specific application and jurisdiction.

Q: Can I mix different part numbers in the same assembly?

A: All listed parts are electrically and mechanically equivalent within the TA45 series specification. Assembly mixing is permissible from a functional standpoint; however, design documentation should specify the approved part number(s) for traceability and supply chain management.

Q: What inventory levels are available for each substitute part?

A: Current inventory ranges from 768 to 1180 pieces across the substitute part family. Verify real-time availability with your supplier before finalizing procurement decisions.

Request Quote (Ships tomorrow)