Request Quote
(Ships tomorrow)
SCHURTER 4430.3346 Thermal Circuit Breaker Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.3346 is a thermal circuit breaker rated for 10A at 240V AC / 60V DC with pushbutton actuation and panel mount configuration. This component is classified as Active product status and complies with international safety standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Substitute parts are identified based on identical electrical and mechanical specifications within the TA45 series.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4430.3346 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Pushbutton |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4430.3346 are qualified based on parametric equivalence within the TA45 series. All substitute parts share identical specifications across the following critical parameters:
- Current Rating: 10A
- Voltage Rating: 240V AC / 60V DC
- Breaker Type: Thermal
- Mounting Type: Panel Mount
- Actuator Type: Pushbutton
- Number of Poles: 2
- Series: TA45
- Product Status: Active
- RoHS Compliance: ROHS3 Compliant
The substitute parts 4430.2513, 4430.258, 4430.3424, 4430.3511, and 4430.3515 are functionally and mechanically interchangeable with the primary part number 4430.3346 for applications requiring thermal circuit protection at the specified voltage and current ratings.
Parameter Comparison
| Part Number | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting Type | Actuator Type | Poles | Series | Product Status | RoHS Status | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4430.3346 | 10A | 240V | 60V | Thermal | Panel Mount | Pushbutton | 2 | TA45 | Active | ROHS3 Compliant | 692 |
| 4430.2513 | 10A | 240V | 60V | Thermal | Panel Mount | Pushbutton | 2 | TA45 | Active | ROHS3 Compliant | 1092 |
| 4430.258 | 10A | 240V | 60V | Thermal | Panel Mount | Pushbutton | 2 | TA45 | Active | ROHS3 Compliant | 1189 |
| 4430.3424 | 10A | 240V | 60V | Thermal | Panel Mount | Pushbutton | 2 | TA45 | Active | ROHS3 Compliant | 1050 |
| 4430.3511 | 10A | 240V | 60V | Thermal | Panel Mount | Pushbutton | 2 | TA45 | Active | ROHS3 Compliant | 982 |
| 4430.3515 | 10A | 240V | 60V | Thermal | Panel Mount | Pushbutton | 2 | TA45 | Active | ROHS3 Compliant | 885 |
Engineering Selection Recommendations
All listed substitute parts maintain Active product status and ROHS3 compliance. The primary selection criteria are inventory availability and compliance certification requirements. Parts 4430.3346, 4430.2513, 4430.258, 4430.3424, 4430.3511, and 4430.3515 all carry approval from CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077, with the exception that 4430.3424 does not list specific approval agencies in the provided data. For applications requiring documented compliance with all listed standards, parts 4430.3346, 4430.2513, 4430.258, 4430.3511, and 4430.3515 are suitable selections.
Frequently Asked Questions (FAQ)
Q: Are all listed part numbers functionally identical? A: Yes. All substitute parts share identical electrical ratings (10A, 240V AC, 60V DC), thermal breaker type, pushbutton actuation, panel mount configuration, and 2-pole design within the TA45 series.
Q: What determines substitutability for SCHURTER 4430.3346? A: Substitutability is determined by matching current rating, voltage ratings (AC and DC), breaker type, mounting type, actuator type, number of poles, and series designation. All listed parts meet these criteria.
Q: Can I use these parts interchangeably in existing designs? A: Yes, provided the application circuit and panel mounting specifications accommodate the identical mechanical and electrical characteristics of the substitute part.
Q: Are there compliance differences between the substitute parts? A: All substitute parts carry ROHS3 compliance and REACH Unaffected status. Approval agency certifications are consistent across parts 4430.3346, 4430.2513, 4430.258, 4430.3511, and 4430.3515.
Q: Which part number should I select based on availability? A: Part 4430.258 has the highest inventory (1189 Pcs), followed by 4430.2513 (1092 Pcs) and 4430.3424 (1050 Pcs). Selection should be based on project lead time requirements and compliance certification needs.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts