SCHURTER 4430.3237 Thermal Circuit Breaker Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.3237 is a thermal circuit breaker rated for 10A at 240V AC / 60V DC with rocker panel mount actuation and dual-pole configuration. This component is classified as Active product status and is ROHS3 compliant. Equivalent and substitute parts within the TA45 series maintain identical electrical and mechanical specifications, enabling direct replacement in applications requiring thermal overcurrent protection in AC and DC circuits.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4430.3237 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| Packaging | Bulk |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4430.3237 are determined by strict equivalence across the following parameters:
- Current Rating: 10A
- Voltage Rating - AC: 240V
- Voltage Rating - DC: 60V
- Breaker Type: Thermal
- Mounting Type: Panel Mount
- Actuator Type: Rocker
- Number of Poles: 2
- Series: TA45
- Product Status: Active
All substitute parts listed maintain identical electrical specifications and mechanical form factor, ensuring functional interchangeability without circuit redesign or mechanical modification.
Parameter Comparison
| Manufacturer Part Number | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting Type | Actuator Type | Poles | Series | Product Status | RoHS Status | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4430.3237 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1079 |
| 4430.0022 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 890 |
| 4430.0413 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1180 |
| 4430.047 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1088 |
| 4430.0778 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1193 |
| 4430.0861 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1086 |
| 4430.0963 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1145 |
| 4430.1038 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 940 |
| 4430.1477 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1123 |
| 4430.1849 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 826 |
| 4430.1892 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1268 |
Engineering Selection Recommendations
All listed substitute parts are Active status components manufactured by SCHURTER Inc. within the TA45 series. Selection among equivalent parts may be based on inventory availability and regional compliance certifications. Parts 4430.0022, 4430.047, 4430.0778, 4430.0861, 4430.0963, 4430.1038, 4430.1849, and 4430.1892 carry additional approval agency certifications including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. The main part 4430.3237 and parts 4430.0413 and 4430.1477 do not list these additional certifications in the provided data. All parts maintain ROHS3 compliance and REACH unaffected status.
Frequently Asked Questions (FAQ)
Q: Can 4430.0022 replace 4430.3237 directly? A: Yes. Both parts share identical electrical ratings (10A, 240V AC, 60V DC), thermal breaker type, rocker actuation, dual-pole configuration, and panel mount form factor within the TA45 series.
Q: What is the difference between the substitute parts? A: All substitute parts maintain identical electrical and mechanical specifications. Differences exist only in approval agency certifications and inventory levels. Parts with CSA, EN, GB, IEC, and UL certifications provide additional regional compliance documentation.
Q: Are there any mechanical compatibility concerns when substituting? A: No. All parts are panel mount rocker actuators with identical mounting specifications and form factor within the TA45 series.
Q: Which substitute part has the highest inventory availability? A: Part 4430.1892 has the highest inventory at 1268 pieces.
Q: Do all substitute parts meet RoHS requirements? A: Yes. All listed parts are ROHS3 compliant and REACH unaffected.
Q: Can I use a substitute part with additional certifications in place of the main part? A: Yes. Parts with additional certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077) are fully equivalent and may provide enhanced compliance documentation for specific regional or application requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts