SCHURTER 4430.3142 Circuit Breaker Thermal 8A 240VAC 60VDC Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.3142 is a thermal circuit breaker rated for 8A at 240V AC and 60V DC, featuring a rocker panel mount actuator with dual-pole configuration. This component is classified as Active product status and is ROHS3 compliant. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical mounting specifications, and regulatory certifications to ensure direct interchangeability in panel-mount circuit protection applications.

Substiute Parts

4430.3142
SCHURTER Inc.In Stock: 8634430.3142 Datasheet
4430.3142
Current Part
4430.0423
SCHURTER Inc.In Stock: 10874430.0423 Datasheet
4430.0423
Parametric Equivalent
4430.0646
SCHURTER Inc.In Stock: 10364430.0646 Datasheet
4430.0646
Parametric Equivalent
4430.1631
SCHURTER Inc.In Stock: 7684430.1631 Datasheet
4430.1631
Parametric Equivalent
4430.2237
SCHURTER Inc.In Stock: 8064430.2237 Datasheet
4430.2237
Parametric Equivalent
4430.2269
SCHURTER Inc.In Stock: 8324430.2269 Datasheet
4430.2269
Parametric Equivalent
4430.3661
SCHURTER Inc.In Stock: 11284430.3661 Datasheet
4430.3661
Parametric Equivalent
4435.009
SCHURTER Inc.In Stock: 7614435.009 Datasheet
4435.009
Parametric Equivalent
4435.0272
SCHURTER Inc.In Stock: 10664435.0272 Datasheet
4435.0272
Parametric Equivalent
4435.0345
SCHURTER Inc.In Stock: 9094435.0345 Datasheet
4435.0345
Parametric Equivalent
4435.0356
SCHURTER Inc.In Stock: 7454435.0356 Datasheet
4435.0356
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 4430.3142
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Current Rating 8A
Voltage Rating - AC 240V
Voltage Rating - DC 60V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Product Status Active
RoHS Status ROHS3 Compliant
Approval Agencies CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077

Substitute Part Grouping Explanation

Substitute parts for the SCHURTER 4430.3142 are qualified based on the following criteria:

Electrical Parameters (Must Match):

  • Current Rating: 8A
  • Voltage Rating - AC: 240V
  • Voltage Rating - DC: 60V
  • Breaker Type: Thermal
  • Number of Poles: 2

Mechanical Parameters (Must Match):

  • Mounting Type: Panel Mount
  • Actuator Type: Rocker

Regulatory & Compliance (Must Match):

  • RoHS Status: ROHS3 Compliant
  • REACH Status: REACH Unaffected
  • Approval Agencies: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077

Substitute parts are organized into two series groups: TA45 series (direct series equivalents) and TA35 series (cross-series equivalents with identical electrical and mechanical specifications).

Parameter Comparison

Part Number Series Current Rating Voltage AC Voltage DC Mounting Type Actuator Type Poles Product Status RoHS Status Inventory (Pcs)
4430.3142 TA45 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 802
4430.0423 TA45 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 1031
4430.0646 TA45 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 995
4430.1631 TA45 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 721
4430.2237 TA45 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 765
4430.2269 TA45 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 785
4430.3661 TA45 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 1018
4435.009 TA35 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 749
4435.0272 TA35 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 1008
4435.0345 TA35 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 875
4435.0356 TA35 8A 240V 60V Panel Mount Rocker 2 Active ROHS3 Compliant 677

Engineering Selection Recommendations

All listed substitute parts maintain identical electrical specifications (8A, 240V AC, 60V DC) and mechanical configuration (panel mount, rocker actuator, dual-pole). Selection between TA45 and TA35 series variants is determined by application-specific mechanical envelope requirements, as both series meet the same electrical and regulatory criteria.

All substitute parts carry Active product status and ROHS3 compliance. Parts with documented approval agencies (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077) are suitable for applications requiring these specific certifications. Parts without explicitly listed approval agencies should be cross-referenced with application requirements before selection.

Inventory availability ranges from 677 to 1031 pieces across all substitute options, enabling supply chain flexibility for production requirements.

Frequently Asked Questions (FAQ)

Q: Can TA35 series parts substitute for TA45 series parts? A: Yes. Both TA35 and TA45 series parts listed meet identical electrical ratings (8A, 240V AC, 60V DC), mounting type (panel mount), actuator type (rocker), and pole configuration (2-pole). Series designation reflects internal design architecture but does not affect electrical or mechanical interchangeability for the specified parameters.

Q: What are the key parameters that determine substitutability? A: Substitutability is determined by: current rating (8A), AC voltage (240V), DC voltage (60V), breaker type (thermal), mounting type (panel mount), actuator type (rocker), and number of poles (2). All listed substitutes match these parameters exactly.

Q: Are all substitute parts ROHS3 compliant? A: Yes. All substitute parts listed carry ROHS3 Compliant status and REACH Unaffected designation, meeting environmental regulatory requirements.

Q: Do all substitute parts carry the same regulatory approvals? A: Most substitute parts carry CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 approvals. Part 4435.0272 does not list approval agencies in the provided data. Verify specific approval requirements for your application before selection.

Q: What is the difference between parts with "Not Applicable" and "Vendor Undefined" MSL ratings? A: Moisture Sensitivity Level (MSL) designation does not affect circuit breaker functionality or substitutability. Both designations indicate the component's moisture handling classification. This parameter does not restrict interchangeability.

Q: Can I use these parts interchangeably in existing designs? A: Yes, provided your application requires 8A thermal circuit protection at 240V AC / 60V DC with panel mount rocker actuator configuration. Mechanical envelope and connector compatibility should be confirmed for your specific panel design.

Request Quote (Ships tomorrow)