SCHURTER 4430.3021 Circuit Breaker Thermal 4A 240VAC 60VDC Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.3021 is a thermal circuit breaker rated for 4A at 240V AC and 60V DC, featuring a rocker actuator and panel mount configuration in the TA45 series. This component is active in production and ROHS3 compliant. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical form factor, and functional specifications to ensure direct interchangeability in applications requiring thermal overcurrent protection.

Substiute Parts

4430.3021
SCHURTER Inc.In Stock: 10974430.3021 Datasheet
4430.3021
Current Part
4430.0706
SCHURTER Inc.In Stock: 7104430.0706 Datasheet
4430.0706
Parametric Equivalent
4430.2421
SCHURTER Inc.In Stock: 6744430.2421 Datasheet
4430.2421
Parametric Equivalent
4430.2437
SCHURTER Inc.In Stock: 10914430.2437 Datasheet
4430.2437
Parametric Equivalent
4430.3216
SCHURTER Inc.In Stock: 9954430.3216 Datasheet
4430.3216
Parametric Equivalent
4430.34
SCHURTER Inc.In Stock: 7824430.34 Datasheet
4430.34
Parametric Equivalent
4430.3676
SCHURTER Inc.In Stock: 8494430.3676 Datasheet
4430.3676
Parametric Equivalent
4430.3742
SCHURTER Inc.In Stock: 7464430.3742 Datasheet
4430.3742
Parametric Equivalent
4435.0009
SCHURTER Inc.In Stock: 11574435.0009 Datasheet
4435.0009
Parametric Equivalent
4435.0125
SCHURTER Inc.In Stock: 12064435.0125 Datasheet
4435.0125
Parametric Equivalent
4435.0129
SCHURTER Inc.In Stock: 7804435.0129 Datasheet
4435.0129
Parametric Equivalent
4435.0276
SCHURTER Inc.In Stock: 8304435.0276 Datasheet
4435.0276
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 4430.3021
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Current Rating 4A
Voltage Rating - AC 240V
Voltage Rating - DC 60V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Product Status Active
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the 4430.3021 are qualified based on the following critical parameters that determine functional interchangeability:

  • Current Rating: 4A
  • Voltage Rating - AC: 240V
  • Voltage Rating - DC: 60V
  • Breaker Type: Thermal
  • Mounting Type: Panel Mount
  • Actuator Type: Rocker
  • Number of Poles: 2
  • Product Status: Active

All substitute parts listed maintain identical electrical specifications and mechanical mounting characteristics. Parts are grouped into two series classifications: TA45 series (4430.xxxx variants) and TA35 series (4435.xxxx variants). Both series meet the specified electrical and mechanical requirements for direct substitution.

Parameter Comparison

Part Number Series Current Rating Voltage AC Voltage DC Breaker Type Mounting Actuator Poles Status RoHS Inventory (Pcs)
4430.3021 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 1062
4430.0706 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 641
4430.2421 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 626
4430.2437 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 1010
4430.3216 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 977
4430.34 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 744
4430.3676 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 834
4430.3742 TA45 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 658
4435.0009 TA35 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 1147
4435.0125 TA35 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 1191
4435.0129 TA35 4A 240V 60V Thermal Panel Mount Rocker 2 Active ROHS3 765

Engineering Selection Recommendations

All listed substitute parts maintain active product status and ROHS3 compliance, ensuring regulatory alignment with the original 4430.3021 specification. Part 4430.0706 carries additional approval certifications including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077, providing enhanced documentation for applications requiring third-party validation. Part 4430.2421 similarly includes the same approval agency certifications.

Selection between TA45 series variants (4430.xxxx) and TA35 series variants (4435.xxxx) depends on mechanical form factor compatibility within the target application, as both series satisfy identical electrical performance requirements. Inventory availability ranges from 626 to 1191 pieces across all qualified substitutes, supporting procurement flexibility.

Frequently Asked Questions (FAQ)

Q: Can TA35 series parts (4435.xxxx) directly replace TA45 series parts (4430.xxxx)?

A: Yes. Both series are qualified substitutes based on matching electrical ratings (4A, 240V AC, 60V DC), thermal breaker type, rocker actuator, 2-pole configuration, and panel mount form factor. Series designation reflects internal design variants that do not affect functional interchangeability for the specified electrical parameters.

Q: What determines whether a part qualifies as a substitute for 4430.3021?

A: Substitution is based on matching current rating (4A), AC voltage (240V), DC voltage (60V), breaker type (thermal), mounting configuration (panel mount), actuator style (rocker), and pole count (2). All listed parts meet these criteria.

Q: Are there differences in approval certifications among the substitute parts?

A: Parts 4430.0706 and 4430.2421 include documented approvals from CSA, EN, GB, IEC, and UL standards. Other parts maintain ROHS3 compliance and active status without listed third-party certifications in the provided data. Applications requiring specific certification documentation should reference 4430.0706 or 4430.2421.

Q: How should I select between multiple substitute options?

A: Selection criteria include series preference (TA45 vs TA35), inventory availability, and certification requirements. All parts are electrically and mechanically equivalent for the specified 4A 240VAC 60VDC thermal circuit breaker application.

Q: Is the MSL (Moisture Sensitivity Level) rating consistent across all parts?

A: Most parts are rated as Not Applicable. Part 4430.34 is listed as Vendor Undefined. This parameter does not affect substitution eligibility for thermal circuit breaker applications.

Request Quote (Ships tomorrow)