Request Quote
(Ships tomorrow)
SCHURTER 4430.2949 Circuit Breaker Thermal 10A 240VAC 60VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.2949 is a thermal circuit breaker rated for 10A at 240V AC and 60V DC, featuring a rocker actuator and panel mount configuration in the TA45 series. This component is classified as Active product status and complies with international safety standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Substitute parts are identified when identical electrical ratings, mechanical mounting specifications, and regulatory certifications are maintained across the product line.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Packaging | Bulk |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
Substitute Part Grouping Explanation
All substitute parts listed maintain identical electrical and mechanical parameters as the main part 4430.2949. Substitution eligibility is determined by the following criteria:
- Current Rating: 10A (exact match required)
- Voltage Rating AC: 240V (exact match required)
- Voltage Rating DC: 60V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Rocker (exact match required)
- Number of Poles: 2 (exact match required)
- Series: TA45 (exact match required)
- Manufacturer: SCHURTER Inc. (exact match required)
- RoHS Status: ROHS3 Compliant (exact match required)
- REACH Status: REACH Unaffected (exact match required)
All substitute parts meet these criteria and are therefore electrically and mechanically interchangeable with part 4430.2949.
Parameter Comparison
| Part Number | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting | Actuator | Poles | Series | RoHS | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|
| 4430.2949 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 889 |
| 4430.0022 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 890 |
| 4430.0413 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 1180 |
| 4430.047 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 1088 |
| 4430.0778 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 1193 |
| 4430.0861 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 1086 |
| 4430.0963 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 1145 |
| 4430.1038 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 940 |
| 4430.1477 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 1123 |
| 4430.1849 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 826 |
| 4430.1892 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | ROHS3 | 1268 |
Engineering Selection Recommendations
All listed substitute parts are Active product status and maintain full compliance with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. Selection among equivalent parts may be based on inventory availability and procurement lead times. All parts are ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory requirements for industrial circuit breaker applications.
Frequently Asked Questions (FAQ)
Q: Can I substitute any of these part numbers for 4430.2949 in my application?
A: Yes. All listed parts are parametric equivalents with identical electrical ratings (10A, 240V AC, 60V DC), thermal breaker type, rocker actuator, panel mount configuration, and two-pole design. They are mechanically and electrically interchangeable.
Q: Are there differences in approval certifications between the main part and substitutes?
A: All parts comply with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. Certification compliance is consistent across the product line.
Q: What is the difference between these part numbers if they have identical specifications?
A: The part numbers represent different manufacturing batches or internal production variants within the TA45 series. Electrical and mechanical specifications remain identical across all variants.
Q: Are all these parts available in the same packaging?
A: Yes. All parts are supplied in Bulk packaging as specified.
Q: Do these parts have the same RoHS and REACH compliance status?
A: Yes. All substitute parts are ROHS3 compliant and REACH unaffected, matching the environmental compliance profile of part 4430.2949.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts