SCHURTER 4430.21 Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.21 is an active thermal circuit breaker rated for 6A at 240V AC / 60V DC with rocker panel mount actuation and dual-pole configuration. This component is part of the TA45 series and maintains full compliance with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. Equivalent and substitute parts within this series share identical electrical and mechanical specifications, enabling direct replacement in applications requiring thermal overcurrent protection.

Substiute Parts

4430.21
SCHURTER Inc.In Stock: 7124430.21 Datasheet
4430.21
Current Part
4430.0012
SCHURTER Inc.In Stock: 7364430.0012 Datasheet
4430.0012
Parametric Equivalent
4430.0707
SCHURTER Inc.In Stock: 10104430.0707 Datasheet
4430.0707
Parametric Equivalent
4430.0991
SCHURTER Inc.In Stock: 10744430.0991 Datasheet
4430.0991
Parametric Equivalent
4430.1121
SCHURTER Inc.In Stock: 7724430.1121 Datasheet
4430.1121
Parametric Equivalent
4430.1251
SCHURTER Inc.In Stock: 7204430.1251 Datasheet
4430.1251
Parametric Equivalent
4430.1608
SCHURTER Inc.In Stock: 8924430.1608 Datasheet
4430.1608
Parametric Equivalent
4430.2215
SCHURTER Inc.In Stock: 10054430.2215 Datasheet
4430.2215
Parametric Equivalent
4430.2872
SCHURTER Inc.In Stock: 9434430.2872 Datasheet
4430.2872
Parametric Equivalent
4430.2931
SCHURTER Inc.In Stock: 10154430.2931 Datasheet
4430.2931
Parametric Equivalent
4430.3456
SCHURTER Inc.In Stock: 7354430.3456 Datasheet
4430.3456
Parametric Equivalent
4430.3552
SCHURTER Inc.In Stock: 10274430.3552 Datasheet
4430.3552
Parametric Equivalent
4435.0031
SCHURTER Inc.In Stock: 8744435.0031 Datasheet
4435.0031
Parametric Equivalent
4435.0042
SCHURTER Inc.In Stock: 16304435.0042 Datasheet
4435.0042
Parametric Equivalent
4435.0089
SCHURTER Inc.In Stock: 7674435.0089 Datasheet
4435.0089
Parametric Equivalent
4435.0278
SCHURTER Inc.In Stock: 8314435.0278 Datasheet
4435.0278
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Current Rating 6A
Voltage Rating - AC 240V
Voltage Rating - DC 60V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Product Status Active
RoHS Status ROHS3 Compliant
Approval Agencies CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077

Substitute Part Grouping Explanation

All substitute parts listed maintain parametric equivalence to the main part 4430.21 across all critical electrical and mechanical parameters. Substitution is valid based on the following criteria:

  • Current Rating: 6A (identical across all parts)
  • Voltage Rating: 240V AC / 60V DC (identical across all parts)
  • Breaker Type: Thermal (identical across all parts)
  • Mounting Configuration: Panel Mount with Rocker actuation (identical across all parts)
  • Pole Configuration: 2-pole (identical across all parts)
  • Series Classification: TA45 (identical across all parts)
  • Regulatory Compliance: All parts meet CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards
  • Environmental Status: ROHS3 Compliant, REACH Unaffected (identical across all parts)

These parts are functionally interchangeable for direct replacement applications.

Parameter Comparison

Part Number Manufacturer Series Current Rating Voltage AC Voltage DC Breaker Type Mounting Type Poles Actuator Product Status RoHS Status Inventory (Pcs)
4430.21 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 681
4430.0012 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 662
4430.0707 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 926
4430.0991 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 1026
4430.1121 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 686
4430.1251 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 705
4430.1608 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 875
4430.2215 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 943
4430.2872 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 836
4430.2931 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 934
4430.3456 SCHURTER Inc. TA45 6A 240V 60V Thermal Panel Mount 2 Rocker Active ROHS3 Compliant 718

Engineering Selection Recommendations

All listed substitute parts are active products with full regulatory compliance to CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. Selection among equivalent parts may be based on inventory availability and lead time requirements. All parts maintain ROHS3 compliance and REACH unaffected status, ensuring environmental and regulatory conformance across all options.

Frequently Asked Questions (FAQ)

Q: Can all listed parts be used interchangeably with SCHURTER 4430.21?

A: Yes. All substitute parts share identical electrical ratings (6A, 240V AC / 60V DC), thermal breaker type, dual-pole configuration, rocker panel mount actuation, and regulatory certifications. Direct replacement is supported.

Q: What determines if a part is a valid substitute?

A: Substitution validity is based on matching current rating, voltage ratings (AC and DC), breaker type, mounting configuration, pole count, series classification, and regulatory compliance. All listed parts meet these criteria.

Q: Are there differences in packaging or mechanical form factor?

A: All parts are specified as Bulk packaging with Panel Mount configuration and Rocker actuation. No mechanical or form factor differences exist among the listed equivalents.

Q: Do all substitute parts meet the same regulatory standards?

A: Yes. All parts comply with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Environmental compliance (ROHS3, REACH Unaffected) is consistent across all options.

Q: How should inventory levels influence part selection?

A: Inventory availability ranges from 662 to 1026 pieces across the substitute options. Selection may prioritize parts with higher stock levels to minimize lead time in procurement scenarios.

Request Quote (Ships tomorrow)