Request Quote
(Ships tomorrow)
Circuit Breaker Thermal 20A 240VAC 60VDC SCHURTER TA45 4430.1944
Part Overview
The SCHURTER 4430.1944 is a thermal circuit breaker designed for panel mount applications with a 20A current rating at 240V AC and 60V DC. This component provides overcurrent protection in industrial and commercial electrical systems. The part is currently active in production with 1131 units in stock. Alternative equivalent models may be required due to inventory constraints, application-specific certifications, or regional compliance requirements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4430.1944 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 20A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Illumination | Orange |
| Illumination Voltage | 110V Nominal |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
Substitute Part Grouping Explanation
The SCHURTER 4430.2084 is a parametric equivalent to the 4430.1944 based on the following critical electrical and mechanical parameters:
- Current Rating: 20A (identical)
- Voltage Rating - AC: 240V (identical)
- Voltage Rating - DC: 60V (identical)
- Breaker Type: Thermal (identical)
- Mounting Type: Panel Mount (identical)
- Actuator Type: Rocker (identical)
- Number of Poles: 2 (identical)
- Illumination: Orange (identical)
- Illumination Voltage: 110V Nominal (identical)
- Series: TA45 (identical)
Both parts are manufactured by SCHURTER Inc. and maintain identical functional specifications for overcurrent protection applications. The substitution is valid where either part number can fulfill the same electrical and mechanical requirements.
Parameter Comparison
| Parameter | 4430.1944 | 4430.2084 |
|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. |
| Series | TA45 | TA45 |
| Breaker Type | Thermal | Thermal |
| Current Rating | 20A | 20A |
| Voltage Rating - AC | 240V | 240V |
| Voltage Rating - DC | 60V | 60V |
| Mounting Type | Panel Mount | Panel Mount |
| Actuator Type | Rocker | Rocker |
| Number of Poles | 2 | 2 |
| Illumination | Orange | Orange |
| Illumination Voltage | 110V Nominal | 110V Nominal |
| Product Status | Active | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| Approval Agency | Not specified | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
Engineering Selection Recommendations
Both the 4430.1944 and 4430.2084 are active production components with ROHS3 compliance and REACH unaffected status. The 4430.2084 carries additional approval agency certifications including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Selection between these parts should be based on regional regulatory requirements and specific application certifications. Where multi-regional compliance is required, the 4430.2084 with its documented approval agencies may be the preferred choice. Both parts are electrically and mechanically interchangeable for 20A thermal circuit breaker applications at 240V AC and 60V DC.
Frequently Asked Questions (FAQ)
Q: Are the 4430.1944 and 4430.2084 electrically interchangeable? A: Yes. Both parts have identical current ratings (20A), voltage ratings (240V AC, 60V DC), breaker type (thermal), and all other electrical specifications. They are direct parametric equivalents.
Q: What is the difference between these two part numbers? A: The primary difference is that the 4430.2084 includes documented approval agency certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), while the 4430.1944 does not list specific certifications in the provided data.
Q: Can I use 4430.2084 as a replacement for 4430.1944 in existing designs? A: Yes, provided the application does not have specific part number requirements. The mechanical and electrical specifications are identical, and both are panel mount rocker actuator thermal breakers with 2 poles and orange illumination.
Q: Are there any packaging differences? A: Both parts are supplied in bulk packaging. No packaging format differences are specified in the technical data.
Q: Which part should I select for new designs? A: Selection should be based on regional compliance requirements. The 4430.2084 with its documented approval agencies is suitable for applications requiring multi-regional certifications. The 4430.1944 is suitable where specific certifications are not mandated.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts