SCHURTER 4430.1776 Circuit Breaker Thermal - Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.1776 is a thermal circuit breaker rated for 1.2A at 240V AC / 60V DC with rocker panel mount actuation and dual-pole configuration. This component is classified as Active product status with full compliance to international safety standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Substitute parts are identified when equivalent electrical ratings, mechanical mounting characteristics, and regulatory compliance profiles align with the original specification.

Substiute Parts

4430.1776
SCHURTER Inc.In Stock: 7624430.1776 Datasheet
4430.1776
Current Part
4430.1624
SCHURTER Inc.In Stock: 10404430.1624 Datasheet
4430.1624
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 4430.1776
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Current Rating 1.2A
Voltage Rating - AC 240V
Voltage Rating - DC 60V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Product Status Active
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the SCHURTER 4430.1776 is determined by the following critical parameters:

  • Current Rating: 1.2A (exact match required)
  • Voltage Rating - AC: 240V (exact match required)
  • Voltage Rating - DC: 60V (exact match required)
  • Breaker Type: Thermal (exact match required)
  • Mounting Type: Panel Mount (exact match required)
  • Actuator Type: Rocker (exact match required)
  • Number of Poles: 2 (exact match required)
  • Series: TA45 (same product family)
  • Regulatory Compliance: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077

The identified substitute part 4430.1624 meets all electrical and mechanical parameters specified above, confirming functional and physical interchangeability within the TA45 series.

Parameter Comparison

Parameter 4430.1776 (Main) 4430.1624 (Substitute) Match
Manufacturer SCHURTER Inc. SCHURTER Inc.
Series TA45 TA45
Breaker Type Thermal Thermal
Current Rating (Amps) 1.2A 1.2A
Voltage Rating - AC 240V 240V
Voltage Rating - DC 60V 60V
Mounting Type Panel Mount Panel Mount
Actuator Type Rocker Rocker
Number of Poles 2 2
Product Status Active Active
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

Both the SCHURTER 4430.1776 and 4430.1624 are Active status products within the TA45 series, maintaining identical electrical specifications and mechanical form factors. Both components satisfy the same regulatory framework including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications. Both are ROHS3 compliant and REACH unaffected. Selection between these parts may be based on inventory availability and lead time considerations, as all functional and compliance parameters are equivalent.

Frequently Asked Questions (FAQ)

Q: Can SCHURTER 4430.1624 directly replace SCHURTER 4430.1776 in existing designs?

A: Yes. Both parts are identical in current rating (1.2A), voltage ratings (240V AC / 60V DC), breaker type (thermal), mounting configuration (panel mount rocker), pole count (2), and series designation (TA45). No circuit redesign or mechanical modification is required.

Q: Are there any compliance differences between these two part numbers?

A: No. Both parts maintain identical regulatory certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), RoHS status (ROHS3 compliant), and REACH classification (unaffected).

Q: What parameters must match for a part to be considered a true substitute?

A: For thermal circuit breakers in the TA45 series, the following parameters must match exactly: current rating, AC voltage rating, DC voltage rating, breaker type, mounting type, actuator type, and pole count. Deviations in any of these parameters disqualify a part from substitution eligibility.

Q: Is packaging type a factor in substitution compatibility?

A: Packaging type (bulk, tape and reel, etc.) does not affect electrical or mechanical compatibility. It is a logistics consideration only and does not impact circuit performance or physical installation.

Q: What should be verified before implementing a substitute part in production?

A: Confirm that all electrical parameters (current, voltage ratings) and mechanical specifications (mounting type, actuator style, pole configuration) match the original design requirements. Verify that the substitute part maintains the same regulatory certifications required by your application.

Request Quote (Ships tomorrow)