SCHURTER 4430.1729 Circuit Breaker Thermal 16A 240VAC 60VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.1729 is a thermal circuit breaker rated for 16A at 240V AC and 60V DC, configured as a 2-pole rocker-actuated panel mount device in the TA45 series. This component is Active status and ROHS3 compliant. Equivalent and substitute parts are identified based on identical electrical ratings, mechanical configuration, and mounting specifications to ensure direct functional interchangeability in panel mount applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4430.1729 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 16A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| Packaging | Bulk |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4430.1729 are qualified based on the following criteria:
Electrical Parameters (Must Match Exactly):
- Current Rating: 16A
- Voltage Rating - AC: 240V
- Voltage Rating - DC: 60V
Mechanical Parameters (Must Match Exactly):
- Breaker Type: Thermal
- Mounting Type: Panel Mount
- Actuator Type: Rocker
- Number of Poles: 2
- Series: TA45
Compliance Parameters:
- RoHS Status: ROHS3 Compliant
- REACH Status: REACH Unaffected
- ECCN: EAR99
- HTSUS: 8536.20.0020
All substitute parts listed maintain identical electrical and mechanical specifications, ensuring direct functional replacement in existing designs without circuit modification or mechanical redesign.
Parameter Comparison
| Part Number | Current Rating (A) | Voltage AC (V) | Voltage DC (V) | Breaker Type | Mounting | Actuator | Poles | Series | Status | RoHS | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4430.1729 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1052 |
| 4430.0034 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 882 |
| 4430.0699 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 969 |
| 4430.071 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 917 |
| 4430.0904 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 922 |
| 4430.1296 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1130 |
| 4430.1563 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 848 |
| 4430.2105 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 771 |
| 4430.2145 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 676 |
| 4430.2374 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 982 |
| 4430.2496 | 16 | 240 | 60 | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 762 |
Engineering Selection Recommendations
All listed substitute parts maintain Active product status and ROHS3 compliance. Parts 4430.0034, 4430.071, 4430.0904, 4430.1296, 4430.2145, 4430.2374, and 4430.2496 carry additional approval certifications including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. These certifications provide expanded regulatory acceptance across North American, European, and international markets.
Selection between equivalent parts should be based on inventory availability, supply chain lead times, and any design-specific approval requirements. All parts are functionally identical for direct substitution in 16A 240VAC 60VDC thermal circuit breaker applications with 2-pole rocker panel mount configuration.
Frequently Asked Questions (FAQ)
Q: Can any of these substitute parts be used interchangeably with the 4430.1729?
A: Yes. All listed parts are parametric equivalents with identical electrical ratings (16A, 240VAC, 60VDC), breaker type (thermal), mounting configuration (panel mount rocker), pole count (2), and series designation (TA45). Direct substitution is supported without circuit or mechanical modification.
Q: What is the difference between parts with and without approval agency certifications?
A: Parts carrying CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications have been tested and approved for use in regulated markets requiring these specific standards. Parts without listed certifications remain ROHS3 compliant and REACH unaffected but may require additional qualification for certain applications or regions.
Q: Are there any inventory considerations when selecting a substitute?
A: Inventory levels vary across the substitute part range from 676 to 1130 pieces. Selection should account for supply chain requirements and lead time constraints. Part 4430.1296 carries the highest inventory at 1130 pieces, while 4430.2145 carries the lowest at 676 pieces.
Q: Do all parts use the same packaging?
A: Yes. All parts are supplied in Bulk packaging consistent with the main part number 4430.1729.
Q: What compliance standards apply to all parts in this group?
A: All parts are ROHS3 compliant, REACH unaffected, classified under ECCN EAR99, and assigned HTSUS code 8536.20.0020. Additional approval agencies apply to specific part numbers as indicated in the parameter comparison table.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts