SCHURTER 4430.1333 Circuit Breaker Thermal 10A 240VAC 60VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.1333 is an active thermal circuit breaker rated for 10A at 240V AC and 60V DC, featuring a rocker panel mount actuator with green illumination at 110V nominal. This two-pole breaker is designed for applications requiring thermal protection in dual-voltage environments. Substitute parts become necessary when the primary part number is unavailable due to inventory constraints or supply chain disruptions, while maintaining identical electrical and mechanical specifications.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Illumination | Green |
| Illumination Voltage | 110V Nominal |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
The substitute parts 4430.0892 and 4430.1626 are parametric equivalents to the main part 4430.1333. Substitution is valid based on the following criteria:
All three parts share identical electrical specifications: 10A current rating, 240V AC and 60V DC voltage ratings, two-pole thermal breaker configuration, and rocker panel mount actuator with green 110V illumination. All parts are manufactured by SCHURTER Inc. within the TA45 series and maintain the same approval certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077). All parts carry active product status, ROHS3 compliance, and identical regulatory classifications (ECCN: EAR99, HTSUS: 8536.20.0020).
Parameter Comparison
| Parameter | 4430.1333 | 4430.0892 | 4430.1626 |
|---|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. | SCHURTER Inc. |
| Series | TA45 | TA45 | TA45 |
| Breaker Type | Thermal | Thermal | Thermal |
| Current Rating (Amps) | 10A | 10A | 10A |
| Voltage Rating - AC | 240V | 240V | 240V |
| Voltage Rating - DC | 60V | 60V | 60V |
| Mounting Type | Panel Mount | Panel Mount | Panel Mount |
| Actuator Type | Rocker | Rocker | Rocker |
| Number of Poles | 2 | 2 | 2 |
| Illumination | Green | Green | Green |
| Illumination Voltage (Nominal) | 110V | 110V | 110V |
| Product Status | Active | Active | Active |
| Approval Agency | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 | EAR99 |
| HTSUS | 8536.20.0020 | 8536.20.0020 | 8536.20.0020 |
Engineering Selection Recommendations
All three part numbers are suitable for direct substitution in applications requiring a 10A thermal circuit breaker with 240V AC and 60V DC ratings in a two-pole rocker panel mount configuration. Selection among 4430.1333, 4430.0892, and 4430.1626 may be based on inventory availability and lead time considerations. All parts maintain identical compliance certifications and active product status, ensuring regulatory and operational equivalence. The choice between these interchangeable parts does not affect circuit protection performance, electrical safety, or system integration.
Frequently Asked Questions (FAQ)
Q: Can 4430.0892 or 4430.1626 be used as direct replacements for 4430.1333?
A: Yes. All three parts are parametric equivalents with identical electrical ratings (10A, 240V AC, 60V DC), mechanical configuration (two-pole rocker panel mount), and regulatory certifications. Direct substitution is valid without circuit modification.
Q: Are there any differences in approval certifications between these part numbers?
A: No. All three parts carry identical approvals: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Regulatory compliance is equivalent across all substitute options.
Q: Do these parts have the same illumination specifications?
A: Yes. All three parts feature green illumination at 110V nominal voltage, ensuring identical visual indication functionality in panel-mounted applications.
Q: What is the basis for substitution between these part numbers?
A: Substitution is based on matching all critical electrical parameters (current rating, voltage ratings, pole configuration), mechanical specifications (mounting type, actuator type), and regulatory certifications. All three parts are manufactured by SCHURTER Inc. within the TA45 series and maintain ROHS3 compliance and identical trade classifications.
Q: Are packaging specifications identical across all three parts?
A: All three parts are supplied in bulk packaging. Packaging format is consistent across 4430.1333, 4430.0892, and 4430.1626.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts