SCHURTER 4430.1296 Circuit Breaker Thermal 16A 240VAC 60VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4430.1296 is a thermal circuit breaker rated for 16A at 240V AC and 60V DC, featuring a rocker panel mount actuator with dual-pole configuration. This component is classified as Active product status and is ROHS3 compliant. Equivalent and substitute parts within the TA45 series maintain identical electrical and mechanical specifications, enabling direct replacement in applications requiring thermal overcurrent protection in AC/DC mixed-voltage environments.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 16A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| Packaging | Bulk |
Substitute Part Grouping Explanation
Substitution eligibility for the SCHURTER 4430.1296 is determined by strict parametric equivalence across the following criteria:
- Current Rating: 16A (exact match required)
- Voltage Rating AC: 240V (exact match required)
- Voltage Rating DC: 60V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Rocker (exact match required)
- Number of Poles: 2 (exact match required)
- Series: TA45 (exact match required)
- Product Status: Active (required for current procurement)
- RoHS Compliance: ROHS3 Compliant (required for regulatory alignment)
All substitute parts listed below meet these criteria without exception and are manufactured by SCHURTER Inc. within the same TA45 series.
Parameter Comparison
| Part Number | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting | Actuator | Poles | Series | Status | RoHS | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4430.1296 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1130 |
| 4430.0034 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 882 |
| 4430.0699 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 969 |
| 4430.071 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 917 |
| 4430.0904 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 922 |
| 4430.1563 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 848 |
| 4430.1729 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1052 |
| 4430.2105 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 771 |
| 4430.2145 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 676 |
| 4430.2374 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 982 |
| 4430.2496 | 16A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 762 |
Engineering Selection Recommendations
All listed substitute parts are functionally equivalent to the SCHURTER 4430.1296 and carry Active product status, confirming ongoing manufacturer support and availability. Each part maintains ROHS3 compliance and meets the regulatory certifications specified: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 (where documented in source data).
Selection among equivalent parts may be based on inventory availability and procurement lead time. Part 4430.1729 offers the highest inventory level at 1052 pieces. Part 4430.2145 carries the lowest inventory at 676 pieces. All parts are packaged in bulk format and carry identical electrical performance characteristics for 16A thermal protection at 240V AC and 60V DC.
Frequently Asked Questions (FAQ)
Q: Can any of these substitute parts be used interchangeably with the SCHURTER 4430.1296?
A: Yes. All listed parts are parametric equivalents within the TA45 series, matching the 16A current rating, 240V AC / 60V DC voltage specifications, thermal breaker type, rocker actuator configuration, dual-pole design, and panel mount form factor. Direct substitution is supported without circuit modification.
Q: What determines whether a part qualifies as a substitute?
A: Substitution eligibility requires exact matching across current rating (16A), AC voltage (240V), DC voltage (60V), breaker type (thermal), mounting method (panel mount), actuator style (rocker), pole count (2), and series designation (TA45). All substitute parts meet these criteria without deviation.
Q: Are there differences in regulatory compliance among the substitute parts?
A: All substitute parts carry ROHS3 compliance status. Approval agencies listed include CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Compliance documentation should be verified with the manufacturer for specific application requirements.
Q: How does packaging affect part selection?
A: All substitute parts are supplied in bulk packaging. No alternative packaging formats are available within this equivalent group. Procurement quantities should align with bulk packaging specifications.
Q: What is the inventory status for each substitute part?
A: Inventory levels range from 676 to 1130 pieces across the substitute group. Current availability should be confirmed with the supplier prior to order placement, as inventory levels are subject to change.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts