SCHURTER 4430.1204 Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.1204 is a thermal circuit breaker rated for 240 V AC and 60 V DC operation with rocker panel mount actuation and dual-pole configuration. This component is classified as Active product status and carries full international approvals including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications. The part is ROHS3 compliant and REACH unaffected. Equivalent and substitute parts within the TA45 series maintain identical electrical and mechanical specifications, enabling direct functional replacement in applications requiring thermal circuit protection across mixed AC/DC voltage environments.

Substiute Parts

4430.1204
SCHURTER Inc.In Stock: 9554430.1204 Datasheet
4430.1204
Current Part
4430.0617
SCHURTER Inc.In Stock: 9564430.0617 Datasheet
4430.0617
Parametric Equivalent
4430.0764
SCHURTER Inc.In Stock: 8594430.0764 Datasheet
4430.0764
Parametric Equivalent
4430.1147
SCHURTER Inc.In Stock: 12864430.1147 Datasheet
4430.1147
Parametric Equivalent
4430.1158
SCHURTER Inc.In Stock: 8734430.1158 Datasheet
4430.1158
Parametric Equivalent
4430.2487
SCHURTER Inc.In Stock: 11634430.2487 Datasheet
4430.2487
Parametric Equivalent
4430.2736
SCHURTER Inc.In Stock: 11134430.2736 Datasheet
4430.2736
Parametric Equivalent
4430.2781
SCHURTER Inc.In Stock: 9844430.2781 Datasheet
4430.2781
Parametric Equivalent
4430.2906
SCHURTER Inc.In Stock: 9004430.2906 Datasheet
4430.2906
Parametric Equivalent
4430.3172
SCHURTER Inc.In Stock: 8994430.3172 Datasheet
4430.3172
Parametric Equivalent
4430.3295
SCHURTER Inc.In Stock: 12034430.3295 Datasheet
4430.3295
Parametric Equivalent
4430.3331
SCHURTER Inc.In Stock: 9094430.3331 Datasheet
4430.3331
Parametric Equivalent
4430.3471
SCHURTER Inc.In Stock: 11174430.3471 Datasheet
4430.3471
Parametric Equivalent
4430.3625
SCHURTER Inc.In Stock: 9574430.3625 Datasheet
4430.3625
Parametric Equivalent
4435.0014
SCHURTER Inc.In Stock: 11504435.0014 Datasheet
4435.0014
Parametric Equivalent
4435.0263
SCHURTER Inc.In Stock: 11644435.0263 Datasheet
4435.0263
Parametric Equivalent
4435.0305
SCHURTER Inc.In Stock: 9694435.0305 Datasheet
4435.0305
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Voltage Rating - AC 240 V
Voltage Rating - DC 60 V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Packaging Bulk
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution within this product family is determined by strict equivalence across the following parameters: voltage rating (240 V AC / 60 V DC), breaker type (thermal), mounting configuration (panel mount rocker), pole count (2-pole), and series designation (TA45). All substitute parts listed maintain identical electrical and mechanical characteristics. Product status differentiation (Active versus Obsolete) and compliance certifications are provided for engineering selection purposes but do not affect functional interchangeability. Parts with Obsolete status (4430.0617, 4430.0764) remain electrically equivalent but may present supply chain considerations.

Parameter Comparison

Part Number Manufacturer Series Breaker Type Voltage AC Voltage DC Mounting Poles Actuator Product Status RoHS Inventory (Pcs)
4430.1204 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 888
4430.0617 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Obsolete ROHS3 931
4430.0764 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Obsolete ROHS3 768
4430.1147 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 1180
4430.1158 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 808
4430.2487 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 1151
4430.2736 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 1097
4430.2781 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 904
4430.2906 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 818
4430.3172 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 800
4430.3295 SCHURTER Inc. TA45 Thermal 240 V 60 V Panel Mount 2 Rocker Active ROHS3 1160

Engineering Selection Recommendations

For new designs and production applications, Active status parts are preferred: 4430.1204, 4430.1147, 4430.1158, 4430.2487, 4430.2736, 4430.2781, 4430.2906, 4430.3172, and 4430.3295. These parts carry full international regulatory approvals (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077) and maintain REACH unaffected status with Not Applicable MSL classification.

Parts 4430.0617 and 4430.0764 are classified as Obsolete and carry REACH Affected designation. While electrically equivalent, these parts present long-term supply chain risk and should be reserved for legacy system maintenance or retrofit applications where original part continuity is required. Obsolete parts may have restricted REACH compliance status requiring additional documentation for certain regulatory jurisdictions.

All Active parts are ROHS3 compliant and suitable for applications requiring environmental compliance across EU, China, and equivalent regulatory frameworks.

Frequently Asked Questions (FAQ)

Q: Can 4430.0617 or 4430.0764 be used as direct replacements for 4430.1204?

A: Yes, from an electrical and mechanical standpoint. Both obsolete parts maintain identical voltage ratings (240 V AC / 60 V DC), thermal breaker type, 2-pole rocker panel mount configuration, and TA45 series designation. However, obsolete parts carry REACH Affected status, which may require additional compliance documentation depending on end-use jurisdiction and customer requirements.

Q: What is the difference between Active and Obsolete product status?

A: Active parts are in current production with ongoing manufacturer support and guaranteed long-term availability. Obsolete parts are no longer manufactured and represent legacy inventory. While functionally equivalent, obsolete parts should not be specified for new designs due to supply chain discontinuation risk.

Q: Are all substitute parts ROHS3 compliant?

A: Yes. All parts listed, including obsolete variants, carry ROHS3 compliance certification. This applies to both Active and Obsolete status parts.

Q: What certifications apply to the main part 4430.1204?

A: The part carries CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 approvals. These certifications cover North American (CSA, UL), European (EN), and international (IEC, GB) regulatory requirements for thermal circuit breakers.

Q: Can I substitute an Active part for an Obsolete part in existing equipment?

A: Yes. All Active parts within this family are electrically and mechanically equivalent to obsolete variants. Substitution is functionally transparent provided the panel mount opening and rocker actuator interface remain unchanged.

Q: What is the REACH status difference between parts?

A: Active parts are REACH Unaffected, indicating no restricted substances of concern under current REACH regulations. Obsolete parts (4430.0617, 4430.0764) are REACH Affected, requiring additional compliance verification for certain applications or export jurisdictions.

Request Quote (Ships tomorrow)