SCHURTER 4410.9012 Circuit Breaker Thermal 16A 240VAC 28VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4410.9012 is a thermal circuit breaker designed for panel mount applications with a 16A current rating at 240V AC and 28V DC. This component is classified as Active product status with full compliance to international safety standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. The push-push actuator with blue illumination at 24V nominal provides visual status indication in control panel environments. Equivalent substitute parts are identified based on matching electrical specifications, mechanical mounting characteristics, and regulatory compliance certifications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4410.9012 |
| Manufacturer | SCHURTER Inc. |
| Series | T12-MSM |
| Breaker Type | Thermal |
| Current Rating | 16A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 28V |
| Mounting Type | Panel Mount |
| Actuator Type | Push-Push |
| Number of Poles | 1 |
| Illumination | Blue |
| Illumination Voltage (Nominal) | 24V |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| Packaging | Bulk |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4410.9012 are identified based on strict equivalence across the following critical parameters:
- Current Rating: 16A
- Voltage Rating - AC: 240V
- Voltage Rating - DC: 28V
- Breaker Type: Thermal
- Mounting Type: Panel Mount
- Actuator Type: Push-Push
- Number of Poles: 1
- Illumination: Blue at 24V nominal
- Series: T12-MSM
- Regulatory Compliance: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
- RoHS Status: ROHS3 Compliant
The substitute part 4410.9010 maintains identical electrical and mechanical specifications across all parameters listed above, ensuring direct functional equivalence in panel mount circuit protection applications.
Parameter Comparison
| Parameter | 4410.9012 (Main Part) | 4410.9010 (Substitute) |
|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. |
| Series | T12-MSM | T12-MSM |
| Breaker Type | Thermal | Thermal |
| Current Rating (Amps) | 16A | 16A |
| Voltage Rating - AC | 240V | 240V |
| Voltage Rating - DC | 28V | 28V |
| Mounting Type | Panel Mount | Panel Mount |
| Actuator Type | Push-Push | Push-Push |
| Number of Poles | 1 | 1 |
| Illumination | Blue | Blue |
| Illumination Voltage (Nominal) | 24V | 24V |
| Product Status | Active | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Approval Agency | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8536.20.0020 | 8536.20.0020 |
Engineering Selection Recommendations
Both the SCHURTER 4410.9012 and 4410.9010 are Active status products with identical electrical ratings, mechanical configurations, and regulatory certifications. Selection between these parts is based on inventory availability and supply chain considerations rather than technical performance differences. Both components satisfy CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 compliance requirements for thermal circuit breaker applications. ROHS3 compliance and REACH Unaffected status confirm environmental regulatory alignment for both parts.
Frequently Asked Questions (FAQ)
Q: Are the 4410.9012 and 4410.9010 directly interchangeable?
A: Yes. Both parts are identical in electrical specifications (16A at 240V AC / 28V DC), mechanical mounting (panel mount, push-push actuator), illumination characteristics (blue at 24V nominal), and regulatory certifications. Direct substitution is supported without circuit modification.
Q: What parameters determine substitution eligibility for this thermal circuit breaker?
A: Substitution is based on matching current rating (16A), voltage ratings (240V AC and 28V DC), breaker type (thermal), mounting configuration (panel mount), actuator style (push-push), pole count (1), illumination type and voltage, and regulatory approval certifications.
Q: Do both parts carry the same regulatory certifications?
A: Yes. Both the 4410.9012 and 4410.9010 are certified to CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards. Both are ROHS3 compliant and REACH Unaffected.
Q: Is there a difference in packaging between these parts?
A: Both parts are supplied in bulk packaging. No packaging format differences exist between the two part numbers.
Q: What is the illumination specification for these circuit breakers?
A: Both parts feature blue illumination with a nominal voltage rating of 24V, providing visual status indication in panel mount applications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts