Request Quote
(Ships tomorrow)
SCHURTER 4410.9003 Circuit Breaker Thermal 10A 240VAC 28VDC Equivalent & Substitute Parts
Part Overview
The SCHURTER 4410.9003 is a thermal circuit breaker rated for 10A at 240V AC and 28V DC, featuring push-push panel mount actuation. This single-pole breaker is part of the T12-MSM series and maintains active product status with ROHS3 compliance. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical mounting characteristics, and functional specifications to ensure direct interchangeability in panel mount applications.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 28V |
| Breaker Type | Thermal |
| Actuator Type | Push-Push |
| Mounting Type | Panel Mount |
| Number of Poles | 1 |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility is determined by strict equivalence across the following parameters:
- Current Rating: 10A (all substitutes match)
- Voltage Rating - AC: 240V (all substitutes match)
- Voltage Rating - DC: 28V (all substitutes match)
- Breaker Type: Thermal (all substitutes match)
- Actuator Type: Push-Push (all substitutes match)
- Mounting Type: Panel Mount (all substitutes match)
- Number of Poles: 1 (all substitutes match)
- RoHS Status: ROHS3 Compliant (all substitutes match)
All identified substitute parts maintain identical electrical and mechanical specifications, confirming direct interchangeability with the primary part number 4410.9003.
Parameter Comparison
| Part Number | Series | Current Rating | Voltage AC | Voltage DC | Breaker Type | Actuator | Mounting | Poles | RoHS Status | Product Status | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4410.9003 | T12-MSM | 10A | 240V | 28V | Thermal | Push-Push | Panel Mount | 1 | ROHS3 | Active | 778 |
| 4410.0015 | T12 | 10A | 240V | 28V | Thermal | Push-Push | Panel Mount | 1 | ROHS3 | Active | 1065 |
| 4410.0367 | T12 | 10A | 240V | 28V | Thermal | Push-Push | Panel Mount | 1 | ROHS3 | Active | 889 |
| 4410.9001 | T12-MSM | 10A | 240V | 28V | Thermal | Push-Push | Panel Mount | 1 | ROHS3 | Active | 839 |
| 4410.9002 | T12-MSM | 10A | 240V | 28V | Thermal | Push-Push | Panel Mount | 1 | ROHS3 | Active | 1111 |
| 4410.9013 | TM12-MSM | 10A | 240V | 28V | Thermal | Push-Push | Panel Mount | 1 | ROHS3 | Active | 974 |
| 4410.9017 | T12-MSM | 10A | 240V | 28V | Thermal | Push-Push | Panel Mount | 1 | ROHS3 | Active | 1026 |
Engineering Selection Recommendations
All substitute parts maintain active product status and ROHS3 compliance. Part numbers 4410.0367 and 4410.9001 include documented approval agency certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), providing additional regulatory documentation for applications requiring third-party validation. Selection between equivalent parts should be based on availability, series designation alignment with existing designs, and inventory levels. All parts are functionally equivalent for direct replacement applications.
Frequently Asked Questions (FAQ)
Q: Can 4410.0015 replace 4410.9003 directly? A: Yes. Both parts share identical electrical ratings (10A, 240V AC, 28V DC), thermal breaker type, push-push actuation, and panel mount configuration. The difference in series designation (T12 versus T12-MSM) does not affect electrical or mechanical interchangeability.
Q: What is the difference between T12-MSM and T12 series designations? A: Series designations reflect internal product line classifications. All parts within this substitution group maintain identical functional specifications and are mechanically and electrically interchangeable.
Q: Are certifications required for my application? A: Certification requirements depend on end-use application and regional standards. Parts 4410.0367 and 4410.9001 include documented approvals from CSA, IEC, EN, GB, and UL standards. Other parts maintain ROHS3 and REACH compliance without additional certifications listed.
Q: Can I mix different part numbers in the same panel? A: Yes. All substitute parts are functionally equivalent and can be used interchangeably in the same application or panel design without modification.
Q: What inventory levels are available? A: Current stock levels range from 778 to 1111 pieces across the substitute group. Part 4410.9002 maintains the highest inventory at 1111 pieces.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts