Request Quote
(Ships tomorrow)
SCHURTER 4410.0421 Equivalent & Substitute Parts
Part Overview
The SCHURTER 4410.0421 is a thermal circuit breaker rated for 400mA at 240V AC and 28V DC, designed for panel mount applications with push-to-reset actuation. This single-pole breaker is part of the T12 series and maintains Active product status with full compliance to international safety standards including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Substitute parts are identified to support procurement flexibility and inventory management when the primary part number is unavailable.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | SCHURTER Inc. |
| Series | T12 |
| Breaker Type | Thermal |
| Current Rating | 400mA |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 28V |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Approval Agencies | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
The SCHURTER 4410.0324 qualifies as a parametric equivalent to the 4410.0421 based on identical electrical and mechanical specifications. Substitution is valid when the following criteria are met:
- Current Rating: 400mA (exact match)
- Voltage Rating - AC: 240V (exact match)
- Voltage Rating - DC: 28V (exact match)
- Breaker Type: Thermal (exact match)
- Mounting Type: Panel Mount (exact match)
- Actuator Type: Push to Reset (exact match)
- Number of Poles: 1 (exact match)
- Series: T12 (exact match)
- Approval Agencies: Identical certifications (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077)
- RoHS Status: ROHS3 Compliant (exact match)
Parameter Comparison
| Parameter | 4410.0421 (Main) | 4410.0324 (Substitute) |
|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. |
| Series | T12 | T12 |
| Breaker Type | Thermal | Thermal |
| Current Rating (Amps) | 400mA | 400mA |
| Voltage Rating - AC | 240V | 240V |
| Voltage Rating - DC | 28V | 28V |
| Mounting Type | Panel Mount | Panel Mount |
| Actuator Type | Push to Reset | Push to Reset |
| Number of Poles | 1 | 1 |
| Product Status | Active | Active |
| Approval Agency | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| Inventory Status | 760 Pcs New Original In Stock | 648 Pcs New Original In Stock |
Engineering Selection Recommendations
Both the 4410.0421 and 4410.0324 are Active status products manufactured by SCHURTER Inc. and carry identical electrical ratings, mechanical specifications, and regulatory certifications. The parts are interchangeable for applications requiring a 400mA thermal circuit breaker at 240V AC / 28V DC with panel mount configuration and push-to-reset actuation. Both parts maintain full compliance with CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 standards, and are ROHS3 compliant. Selection between these part numbers may be based on inventory availability and procurement lead times.
Frequently Asked Questions (FAQ)
Q: Can the 4410.0324 be used as a direct replacement for the 4410.0421?
A: Yes. Both parts are identical in electrical rating (400mA, 240V AC, 28V DC), breaker type (thermal), mounting configuration (panel mount), actuation method (push to reset), and regulatory certifications. They are parametric equivalents within the T12 series.
Q: Are there any differences in packaging or physical dimensions between these parts?
A: Both parts are supplied in Bulk packaging. No dimensional or physical differences are specified in the provided parameters.
Q: Do both parts meet the same regulatory standards?
A: Yes. Both the 4410.0421 and 4410.0324 carry identical approvals: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Both are ROHS3 compliant and REACH unaffected.
Q: What is the basis for substitution between these part numbers?
A: Substitution is based on matching all critical electrical parameters (current rating, voltage ratings for AC and DC), breaker type (thermal), mounting type (panel mount), actuation type (push to reset), pole configuration (single pole), and regulatory compliance. These parameters define functional equivalence for this product category.
Q: Which part should I select if both are available?
A: Selection may be based on current inventory levels and procurement requirements. The 4410.0421 has 760 units in stock, while the 4410.0324 has 648 units available. Both are Active status products suitable for immediate use.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts